AS-BADU-201 | Schneider Modicon Compact 8-channel Universal Analog Input Module
June 03, 2026

AS-BADU-201 | Schneider Modicon Compact 8-channel Universal Analog Input Module

Product Introduction The Schneider Modicon Compact 984 rack-specific 8-channel AI analog signal acquisition module, part of the BADU series, is an original factory discontinued spare part, compatible with the entire series of Modicon 984 CPUs, compatible with standard industrial sensor signals for voltage and current, and is compatible with the BADU-202/204/205/206 hardware rack, with different range configurations.

Description

Model Interpretation

BADU = Analog Input - Analog Input module; 201 = 8-channel single-ended standard range specification; 202 = bipolar, 204 = multi-range, 205 = dedicated for thermal resistance, 206 = dedicated for thermocouples. Technical Specifications

Channel Configuration: 8 isolated analog inputs, single-slot Eurocard installation

Input Range: 0~5VDC, 0~10VDC, 4~20mA single-polarity standard signals. Does not support ±5V/±10V bipolar

Resolution: 12Bit analog-to-digital conversion, full-scale range accuracy ±0.2% FS

Sampling Rate: 25ms per channel, 200ms for full-channel polling

Power Supply Specifications: Backplane 5VDC bus power supply, module power consumption approximately 320mA; external DC24V power supply for field sensors

Dimensions: 58 (W) × 267 (H) × 165 (D) mm, net weight 1.48kg

Environmental Parameters: Operating temperature 0~60℃, storage temperature -40~85℃, humidity ≤80% RH without condensation, IP20 cabinet installation

Interface and Matching Base

Matching terminal base AS-8535-000, compatible with all base units of B883/B884/B885 motion modules, integrated plug-in terminals, 8-channel independent terminal partition arrangement.

Core Functions

8-channel analog-to-digital conversion, converting field analog signals to PLC digital registers; single-channel open-circuit fault diagnosis (4~20mA loop open circuit alarm); panel channel status LED, power LED, fault indicator; backplane register mapping, PLC directly reads collected values, no additional card configuration required; channel grouping isolation, anti-field frequency interference. Applicable scenarios

Chemical liquid level pressure transmitter, rubber and plastic temperature control analog signal acquisition, fan and pump current monitoring, water and electricity auxiliary machine pressure and flow detection, old production line 4-20mA sensor data acquisition.

Operation and Maintenance

Directly insert into Modicon Compact standard I/O slot; abnormal readings should first check the sensor power supply and signal line shielding; check 4mA zero point drift by inspecting the circuit wiring; the BADU-202 bipolar version cannot be directly replaced; the input circuit hardware is different; the rack can be mixed with motion cards, temperature control cards, and digital IO modules.