PXI-2535
Description
Model Explanation
PXI: PXI bus platform (modular instrument standard)
2535: Product serial number, representing 544 cross-point FET high-density matrix switch
Alias: NI-2535, PXI-2535 (FET 4×136 matrix)
Function Positioning: 4×136 single-line ultra-high-density matrix, FET without contact, ultra-high-speed, long-life signal routing
Technical Parameters
Cross-point Number: 544 (fixed 4 rows × 136 columns single-line matrix)
Relay Type: Field Effect Transistor (FET), no mechanical lifespan limit
Maximum Switching Voltage: ±12 VDC / 8 VACrms
Maximum Switching Current: 100 mA/channel
Maximum Switching Power: 1.2 W (single channel)
Bandwidth (–3 dB, 50 Ω): Typical 1 MHz
Thermal Emissivity: Typical <5 μV
Channel Isolation Resistance: Typical >1 GΩ (DC)
Path Resistance: Typical <5 Ω (row to column)
Switching Time: Typical <20 μs
Scanning Rate: 50,000 cross-points/second (far exceeding SSR module)
Maximum Drive Capability: 544 FETs (fully closed)
Trigger Characteristics: PXI trigger line 0–7, minimum pulse width 70 ns; hardware synchronization
I/O Connector: 68-pin male SCSI type
Size: 3U PXI single slot (216 × 20 × 130 mm)
Weight: Approximately 250 g
Operating Temperature: 0–55 °C
Interface and Communication Configuration
PXI Bus Interface: Standard 3U PXI backplane connector, power supply, trigger, clock and communication
Front-end I/O Connector: 68-pin male SCSI, high-density signal output
Terminal Block (optional): TB-2625, etc., supports screw terminals or ribbon cable connections
Control Communication: PXI bus, compatible with NI- SWITCH, MAX, LabVIEW, TestStand
Trigger Synchronization: Hardware trigger input/output, nanosecond-level synchronization, enhancing test throughput
Expansion Capability: Multi-module cascading (via SHC68-C68-S cable), scalable to larger matrix size NI Core function
Ultra-high density 4×136 matrix: 544 intersections, single-slot accommodation, saving chassis slot resources.
FET contactless technology: infinite mechanical lifespan, ultra-high-speed switching at 50,000 times/second, suitable for high-frequency mass production testing.
Low thermal potential and high isolation: <5 μV thermal offset, >1 GΩ isolation, suitable for low-level precise measurement.
Overvoltage fault protection: built-in FET protection circuit to prevent overvoltage damage, enhancing system stability.
Hardware triggering and deterministic timing: minimum trigger pulse width of 70 ns, precise synchronization of multiple instruments, improving test efficiency.
On-board channel diagnosis: real-time monitoring of channel status, rapid fault location, reducing downtime. Applicable scenarios
Semiconductor testing: Wafer testing, chip parameter testing, aging screening, high-density, high-frequency switching requirements.
PCB / Electronic manufacturing: Circuit board conduction testing, functional verification, batch production testing, multi-channel signal routing.
Precise low-level testing: Sensor signal acquisition, instrument calibration, low-voltage signal switching, low thermal offset requirements.
Automated test system (ATE): High-density, high-speed rate test scenarios, shorten test cycle, enhance production capacity.
Small and medium-sized signal routing: Multi-channel signal switching in laboratory / R&D environment, balance density and cost.
User and maintenance instructions
Key usage points
Installation: Standard 3U PXI chassis single slot, lock the panel, ensure the backplane connector is reliably connected.
Configuration: Set channel mapping, trigger parameters and scan sequence through NI-SWITCH or MAX software.
Cabling: Connect TB-2625 terminal block with 68-pin SCSI, then transfer to the tested device; strictly follow the ±12 V/100 mA limit, avoid overload.
Operation monitoring: Use software diagnostic function to monitor channel status in real time, regularly check connection stability.
Environment: Working temperature 0–55 °C, avoid strong electromagnetic interference, dust and condensation; must be well grounded to prevent FET malfunction.
Maintenance instructions
Regular inspection: Check connector tightness, terminal block wiring for looseness every quarter, clean surface dust.
Life management: FET has no mechanical lifespan, but need to monitor electrical stress to avoid long-term overpressure / overcurrent operation.
Fault troubleshooting: When channel不通 or signal abnormal, first check wiring and grounding, then diagnose FET status through software; avoid electrostatic damage to the module.
Storage: When not in use for a long time, power off and store in a dry, dust-proof environment, add a dust cap to the connector to prevent moisture oxidation.
Get a Quote