DU2.1DGU-1
May 12, 2026

DU2.1DGU-1

Description

1. Product Overview

DU2.1DGU-1 is a high-performance electrochemical trace oxygen sensor with dedicated DGU interface structure.
It is designed for ppm-level ultra-low oxygen concentration detection, featuring high sensitivity, excellent linearity, fast response, low temperature drift and long-term stability.
Adopting sealed integrated structure and dedicated DU series standard interface, it is perfectly compatible with DIM series signal modules, DELOMATIC control units and matched DPD sensor bases.
Widely used in nitrogen/argon/hydrogen industry, semiconductor process, laboratory glove box, gas analyzer and industrial online trace oxygen monitoring.

2. Key Features

  • Professional ppm-level trace oxygen detection capability

  • Dedicated DU2.1DGU standard interface, plug-and-play installation

  • Fast T90 response time and quick signal recovery

  • High linear output, convenient for signal conversion and algorithm processing

  • Low temperature coefficient, stable measurement under variable temperature

  • Sealed anti-pollution structure, good anti-interference to background gas

  • Compact cylindrical package, easy integration and field replacement

  • Long service life, low monthly drift for long-term continuous monitoring

3. Technical Specifications

3.1 Performance Parameters

ParameterSpecification
Product ModelDU2.1DGU-1
Working PrincipleDivided-potential Electrochemical Oxygen Sensor
Measurement Range0~10 ppm (custom range optional)
T90 Response Time≤ 7 s
Full Scale Accuracy±2% FS
Linearity Error≤ ±2% FS
Monthly Long-term Drift≤ 1% FS
Temperature Coefficient≤ 3.0%/°C
Operating Temperature0°C ~ +45°C
Working Humidity0%~99% RH, non-condensing
Operating Pressure80~120 kPa
Service Lifetime≥ 24 months (normal ambient)
Shelf Life12 months (original sealed package)

3.2 Mechanical & Interface Parameters

ParameterSpecification
Package FormStandard cylindrical DGU structure
Interface TypeDU2.1 concentric ring interface
Housing MaterialHigh-density polyethylene HDPE
Net WeightApprox. 5 g
Matching BaseDPD02027 / DPD08063
Matching ModuleDIM5-1 / DELOMATIC-3/DGU1

4. Application Scope

  • Trace oxygen monitoring for nitrogen, argon and hydrogen production industry

  • Semiconductor manufacturing process gas and protective atmosphere detection

  • Laboratory glove box, inert gas furnace and vacuum cabinet

  • Portable trace oxygen analyzer and fixed online monitoring instrument

  • Petrochemical, metallurgy welding shielding gas monitoring

  • Food and pharmaceutical packaging residual oxygen detection system

5. Installation & Operation Guide

5.1 Installation Requirements

  1. Adopt vertical installation with air inlet facing upward, keep breathable port unobstructed.

  2. Use matched DPD dedicated base for docking, insert vertically in place without forced twisting.

  3. Adopt sealed gas path connection; recommended PTFE tubing for pipeline layout.

  4. Recommended gas flow rate: 200~500 mL/min; avoid excessive airflow impact.

  5. Keep away from high temperature heat source, strong vibration and corrosive gas environment.

5.2 Preheating & Calibration

  1. After installation and power-on, preheat for 10~15 minutes to stabilize signal.

  2. Zero Calibration: Use high-purity nitrogen (0 ppm O₂) for zero point calibration.

  3. Span Calibration: Use standard low-oxygen gas to complete span calibration.

  4. Recalibration is required when working temperature or environment changes greatly.

6. Safety Precautions

  • Non-explosion-proof type; do not use directly in flammable and explosive hazardous areas.

  • Strictly prevent condensed water, oil liquid and dust from entering the air inlet.

  • Handle with anti-static measures; avoid static damage to internal sensitive components.

  • Do not disassemble the sensor shell privately; internal liquid leakage will cause permanent failure.

  • Avoid long-term exposure to strong corrosive gases such as Cl₂, SO₂ and H₂S.

7. Maintenance & Storage

  • It is recommended to perform zero/span calibration every 3~6 months according to usage.

  • Keep the air inlet filter clean; replace filter if blocked or contaminated.

  • Store in sealed original package at 10~30°C, 30~70% RH, cool and dry environment.

  • Avoid direct sunlight, high temperature and damp stacking storage.

8. Troubleshooting

Fault PhenomenonPossible CauseSolution
No signal outputPoor interface contact / reverse installationReinsert sensor correctly; check DPD base contact
Unstable readingInsufficient preheating / airflow fluctuationFully preheat; stabilize gas flow rate
Slow responseAir inlet blocked / sensor agingClean filter; recalibrate or replace sensor
Large temperature driftWorking temperature sudden changeDo temperature compensation and recalibration

9. Warranty & Disclaimer

  • Product Model: DU2.1DGU-1 Trace Oxygen Sensor

  • Warranty Period: 12 months from delivery date under normal installation and use.

  • Warranty invalid for damage caused by forced disassembly, wrong installation, liquid immersion and man-made damage.

  • All specifications are subject to change without prior notice. The manufacturer reserves the right to optimize product structure and performance.