DELTA VFD004DD21S Product Description
November 07, 2026

DELTA VFD004DD21S Product Description

DELTA VFD004DD21S VFD-DD series 0.4kW 230V single phase elevator door control inverter with anti-pinch and door curve control

Description

DELTA VFD004DD21S Product Description

Overview

DELTA VFD004DD21S is a dedicated elevator door drive inverter of Delta VFD-DD series. DELTA VFD004DD21S is designed for elevator door motor control, supporting both induction motor and permanent magnet door motor, with built-in door curve logic and anti-pinch detection function. DELTA VFD004DD21S is widely used for elevator cabinet assembly and door system spare replacement.

Features

DELTA VFD004DD21S is single-phase 230V input, rated 0.4kW (0.5HP), 2.5A constant torque output. It integrates dedicated door control algorithm, adjustable opening/closing speed curve, soft start and soft stop to reduce door impact. It supports encoder feedback closed-loop position control and current-based anti-pinch protection, which triggers reverse opening when obstacle is detected. DELTA VFD004DD21S comes with 5 digital inputs, 3 digital outputs, 2 relay feedback outputs, and built-in EMC filter. It adopts removable terminal blocks and built-in keypad for parameter setting and status viewing. It supports multi-speed control and door timeout alarm. The suffix S stands for standard version (without CANopen; T version is CANopen model). DELTA VFD004DD21S is natural cooling, compact 55mm depth housing, IP20 protection for cabinet installation.

Specs

Brand: DELTA Model: VFD004DD21S Product series: VFD-DD Product category: Elevator door control inverter Input: Single phase 200–240V AC Applicable motor: 0.4kW Rated output current: 2.5A Output frequency: 0–120Hz Control mode: IM / PM motor vector control Function: Door curve, anti-pinch, position feedback I/O: 5DI, 3DO, 2 relay outputs Built-in: EMC filter Cooling: Natural air cooling Protection: IP20 Version remark: S = standard version

Principle

DELTA VFD004DD21S receives door open/close commands from elevator main controller. The internal special door drive algorithm outputs variable frequency voltage to drive the door motor. It follows preset speed profile to complete slow start, constant speed, slow deceleration and stop. It monitors motor current and encoder position signal in real time. If abnormal current surge is detected, the drive judges obstacle and reverses the door direction to realize anti-pinch safety protection. Relay and digital feedback signals return door status to elevator main controller.

Applications

DELTA VFD004DD21S is exclusively used for elevator door operator control. It is commonly installed on passenger elevators, freight elevators and small lift door systems. It is the core spare part for elevator maintenance, door drive replacement and modernization retrofit.


Get a Quote