Product Specification Document: Bently Nevada 1X35668
Description
Product Specification Document: Bently Nevada 1X35668
1. Product Overview
2. Basic Product Information
Manufacturer and Model Identity
Manufacturer: Bently Nevada, a Baker Hughes company
Model Number: 1X35668 (also referenced as 68135045)
Product Series: 3300 XL NSv Proximity Transducer System
Product Type: Precision Proximity Probe Extension Cable
System Compatibility: 3300 NSv proximity probes, 3300 XL NSv proximitor sensors, 3300/3500 series monitoring systems
Country of Origin: United States
Main Components: PTFE-insulated signal conductors, stainless steel braided shielding, nickel-plated brass connectors, protective outer jacket, strain relief glands
Electrical Characteristics
Signal Type: Eddy-current proximity probe signal (high-frequency AC)
Conductor Insulation: PTFE (Teflon), low dielectric loss, high temperature resistance
Shielding: 316 stainless steel braid, 100% coverage, EMI/RFI suppression
Connector Impedance: Matched to 3300 XL NSv system (50 Ω nominal)
Voltage Rating: 35 VDC maximum (sensor circuit)
Frequency Bandwidth: DC to 10 kHz, supports high-frequency vibration measurement
Signal Loss: ≤0.5 dB at 10 kHz (3 m length)
Isolation: Complete electrical isolation between conductors and shield to eliminate ground loops
Physical and Mechanical
Cable Length: Standard 3 meters (custom lengths available)
Outer Jacket: Flame-retardant, oil-resistant PVC; optional PTFE for extreme temperatures
Diameter: 6 mm (nominal)
Connectors: Nickel-plated brass, threaded coupling, self-aligning; 2-wire termination
Weight: 0.36 kg (3 m length)
Bend Radius: Minimum 50 mm (static), 100 mm (dynamic)
Ingress Protection: IP67 (connectors), IP65 (cable jacket)
Material Durability: 316 stainless steel shield, corrosion-resistant for coastal/offshore use
Environmental Limits
Operating Temperature: -40 °C to +125 °C (-40 °F to +257 °F)
Storage Temperature: -50 °C to +150 °C (-58 °F to +302 °F)
Relative Humidity: 0%–95% RH, non-condensing
Vibration Resistance: 10 g continuous (10 Hz–1 kHz)
Shock Resistance: 20 g transient mechanical shock
Chemical Resistance: Resists oils, greases, hydrocarbons, and mild acids/alkalis
Compliance and Certification
Applicable Standards: API 670, ISO 10816, IEC 61000-6-2, IEC 61000-6-4
Certifications: CE, cULus, ATEX Zone 2, RoHS, ABS marine certification
Hazardous Area Rating: Class I Division 2 / Zone 2, Temperature Class T4
Quality Control: ISO 9001 manufacturing; 100% electrical and mechanical testing prior to shipment
Lifecycle Status: Active production; full support for new installations, retrofits, and replacements
3. Function and Product Positioning
Core Functions
Precision Signal Transmission: Transmits high-frequency eddy-current signals (0–10 kHz) from probes to proximitors with minimal loss, ensuring accurate displacement/vibration measurements
EMI/RFI Protection: Stainless steel braided shielding blocks electromagnetic interference from motors, drives, and power lines, preventing signal distortion
Environmental Protection: Sealed connectors and rugged jacket resist moisture, dust, oil, and extreme temperatures, enabling use in harsh industrial locations
Mechanical Strain Relief: Integrated glands and reinforced ends prevent cable fatigue from vibration, bending, or pulling, extending service life
System Compatibility: Fully interoperable with 3300 XL NSv probes and proximitors, maintaining system calibration and measurement accuracy
Operational Features
Plug-and-Play Installation: Threaded connectors enable quick, tool-free connection to probes and proximitors
Length Flexibility: Standard 3 m length; custom lengths up to 10 m available for complex machinery layouts
Maintenance-Free Design: No moving parts; requires only visual inspection for damage or wear
Calibration Stability: Does not require recalibration after installation; maintains system accuracy over time
Hot-Swap Capability: Can be replaced during system operation without shutting down machinery
Product Positioning
4. Core Performance Parameters
Electrical Performance
Frequency Response: DC to 10 kHz (±0.1 dB flatness)
Characteristic Impedance: 50 Ω ±2 Ω
Insulation Resistance: ≥100 MΩ at 500 VDC
Shield Resistance: ≤0.5 Ω (3 m length)
Signal Attenuation: ≤0.5 dB at 10 kHz
Mechanical Performance
Tensile Strength: ≥500 N (cable); ≥1000 N (connectors)
Bend Cycle Life: ≥10,000 cycles (100 mm bend radius)
Connector Durability: ≥500 mating cycles
Vibration Endurance: 10 g @ 10 Hz–1 kHz, 1000 hours
Reliability
MTBF: >200,000 hours (25 °C, standard conditions)
Warranty: 1-year standard factory warranty; extended options available
Service Life: 10+ years under normal operating conditions
5. General Matching Accessories
Compatible System Components
3300 NSv proximity probes (5 mm/8 mm diameter)
3300 XL NSv proximitor sensors
3300/3500 series monitoring racks and modules
Installation Accessories
Stainless steel cable clamps and mounting brackets
Protective metal conduit for cable routing
Connector dust caps (for unused ports)
Spare O-rings and sealing gaskets
Maintenance and Spares
1X35668 extension cable (replacement)
Connector repair kit (pins, sleeves, gaskets)
Cable cutters and crimping tools (for custom lengths)
Factory calibration certificate and test reports
Supporting Documentation
3300 XL NSv system datasheet
1X35668 installation and maintenance manual
API 670 application guide for proximity transducer systems
Bently Nevada 3300/3500 system integration manual
6. Applicable Equipment and Industry Fields
Primary Applications
Power Generation: Steam/gas turbines, generators, boiler feed pumps, induced draft fans
Oil and Gas: Centrifugal compressors, offshore platform pumps, refinery blowers, pipeline compressors
Petrochemical: Process compressors, reactor agitators, cooling tower fans, gearboxes
Secondary Applications
Industrial Manufacturing: Large motors, machine tools, printing presses, textile machinery
Water/Wastewater: High-pressure pumps, aeration blowers, sludge dewatering equipment
Marine/Offshore: Vessel propulsion systems, cargo pumps, ventilation fans, offshore platform machinery
Compatibility Notes
System Matching: Must be used with 3300 XL NSv probes and proximitors; not compatible with older non-XL 3300 systems
Length Limitations: Maximum recommended length is 10 m to avoid excessive signal attenuation
Routing Guidelines: Avoid routing near high-voltage cables or variable-frequency drives to minimize EMI
Hazardous Areas: Use certified cable glands and conduits in Class I Division 1 locations
Get a Quote