1. Product Overview
2. Basic Product Information
Manufacturer and Model Identity
Manufacturer: Bently Nevada, a Baker Hughes company
Model Number: 1900/65A
Product Series: 1900 Cordant Series General Purpose Equipment Monitor
Product Type: Standalone Multi-Channel Machinery Condition Monitor
System Compatibility: 3300 XL proximity probes, velocity transducers, ICP accelerometers, Type E/J/K/T thermocouples, Pt100/Pt1000 RTDs, Modbus RTU-enabled DCS, SCADA, and PLC systems
Country of Origin: United States
Main Components: Main monitor assembly, integrated LCD display, tactile keypad, multi-functional LED status indicators, removable screw terminal blocks
Electrical Characteristics
Power Supply: 9–32 VDC (nominal 24 VDC); optional 90–250 VAC universal AC input via configured variants
Power Consumption: Maximum 15 W under full-load conditions
Signal Processing: 24-bit high-resolution ADC per channel, 25 kHz bandwidth, configurable 4–8 pole high-pass/low-pass filters (0.5 Hz–25 kHz)
Input Channels: 4 universal transducer inputs (configurable for proximity, velocity, acceleration, Keyphasor); 4 dedicated temperature inputs (thermocouple/RTD compatible)
Output Interfaces: 6 programmable SPDT relay outputs (Alert/Danger/OK); 4 galvanically isolated 4–20 mA analog outputs; 1 buffered raw signal output per transducer channel for external analysis
Communication: RS-485 Modbus RTU (baud rate 9600–115200 bps); optional Ethernet Modbus TCP on select variants
Isolation: Complete galvanic isolation between power, inputs, outputs, and communication ports to eliminate ground loops
Physical and Mechanical
Enclosure: Heavy-duty metal housing with EMI shielding; conformal-coated PCB for dust, moisture, and chemical resistance
Mounting: Standard 35 mm DIN rail; panel-mount compatible
Terminals: Removable screw terminals (12–22 AWG) for easy wiring and maintenance
Human-Machine Interface: LCD for real-time data and configuration; LED indicators for power, run, alarm, and fault status
Ingress Protection: IP20 (standard indoor cabinet installation)
Environmental Limits
Operating Temperature: -20 °C to +70 °C (-4 °F to +158 °F)
Storage Temperature: -30 °C to +90 °C (-22 °F to +194 °F)
Relative Humidity: 5%–95% RH, non-condensing
Vibration Resistance: 5 g continuous (10 Hz–1 kHz)
Shock Resistance: 10 g transient mechanical shock
Compliance and Certification
Applicable Standards: API 670, ISO 10816, IEC 61000-6-2, IEC 61000-6-4
Certifications: CE, cULus, ATEX Zone 2, RoHS, ABS marine certification
Hazardous Area Rating: Class I Division 2 / Zone 2, Temperature Class T4 (non-incendive locations)
Quality Control: ISO 9001 manufacturing; full calibration and functional testing prior to shipment
Lifecycle Status: Active production with full support for new projects, retrofits, and expansions
3. Function and Product Positioning
Core Functions
Multi-Parameter Monitoring: Simultaneous measurement of shaft vibration (displacement/velocity/acceleration), axial position, speed, phase, and bearing/process temperature for full machinery health visibility
Flexible Signal Configuration: Software-selectable sensor types per transducer channel; configurable filters and scaling for diverse measurement needs
Dual-Alarm Management: Independent Alert and Danger setpoints per channel with adjustable hysteresis; six relays programmable for alarm, trip, or interlock logic
Fault Diagnosis & Event Logging: Automatic detection of sensor open/short circuits and signal anomalies; non-volatile memory stores 200 time-stamped events for traceability
Data Integration: Modbus RTU for real-time data upload to DCS/SCADA; isolated 4–20 mA outputs for recorders and analog I/O
Local Operation: Onboard display/keypad for on-site viewing, configuration, and alarm reset without external software
Operational Features
Wide Sensor Compatibility: Full support for Bently Nevada 3300 XL sensors and third-party accelerometers, velocity probes, thermocouples, and RTDs
Hot-Swap Capability: Unit replacement during system operation to minimize downtime
Data Security: Configuration and event logs stored in non-volatile memory (no loss on power cycle)
Scalable Deployment: Standalone use or networked via Modbus for multi-unit monitoring systems
Product Positioning
4. Core Performance Parameters
Measurement Performance
Transducer Channels: Frequency response 0.5 Hz–25 kHz; vibration ranges 10–500 mm/s (velocity), 20–500 m/s² (acceleration), 0–2 mm (displacement)
Temperature Channels: Thermocouple -200 °C to +1300 °C; RTD -200 °C to +850 °C
Accuracy: ±0.1% FS (transducer); ±0.5 °C (temperature)
Repeatability: ±0.05% FS
Filter Options: 4–8 pole configurable high-pass/low-pass filters
Output Performance
Relay Ratings: 5 A @ 30 VDC; NO/NC contacts configurable
Analog Output: 4–20 mA isolated, 500 Ω max load, ±0.1% FS accuracy
Communication: Modbus RTU, up to 247 slaves per RS-485 network
Reliability
MTBF: >150,000 hours (25 °C standard conditions)
Warranty: 1-year standard factory warranty; extended options available
Maintenance: No mandatory maintenance; annual calibration and visual inspection recommended
5. General Matching Accessories
Installation Accessories
Standard 35 mm DIN rail mounting hardware (included)
Optional panel-mount adapter plate
External protective enclosure (dust/humid environments)
Spare terminal blocks and display components
Compatible Sensors
3300 XL series proximity probes and extension cables
Industrial velocity sensors and ICP accelerometers
Type E/J/K/T thermocouples and Pt100/Pt1000 RTDs
System Integration
Modbus RTU-based DCS, PLC, and remote monitoring terminals
1900 Configuration Software (PC-based setup/calibration)
Documentation & Spares
Dedicated 1900/65A datasheet and installation manual
1900 Series application guide and Modbus protocol specification
Factory calibration report and test documents (included)
6. Applicable Equipment and Industry Fields
Primary Applications
Power Generation: Auxiliary pumps, cooling fans, blowers, small compressors (thermal/combined-cycle plants)
Oil and Gas: Refinery fans, platform pumps, auxiliary compressors, pipeline equipment
Petrochemical: Process pumps, cooling tower fans, agitators, gear units
Secondary Applications
Water/Wastewater: Large supply pumps, aeration blowers, process fans
Pulp & Paper: Drive fans, stock pumps, auxiliary transmission equipment
Marine/Offshore: Vessel auxiliary pumps, ventilation fans, non-critical rotating equipment
Compatibility Notes
Power: DC (9–32 VDC) standard; AC variants (90–250 VAC) available
Sensors: Optimized for 3300 XL proximity probes; compatible with third-party sensors via configuration
Networking: Assign unique Modbus slave addresses for multi-unit systems
Hazardous Areas: Use certified safety barriers in Class I Division 1 locations