Product Specification Document: Bently Nevada 1900/65A-01-01-03-00-00
Description
Product Specification Document: Bently Nevada 1900/65A-01-01-03-00-00
1. Product Overview
2. Basic Product Information
Manufacturer and Model Identity
Manufacturer: Bently Nevada, a Baker Hughes company
Model Number: 1900/65A-01-01-03-00-00
Product Series: 1900 Cordant Series General Purpose Equipment Monitor
Product Type: Standalone Multi-Channel Machinery Condition Monitor
Model Code Definition: The suffix
-01-01-03-00-00indicates universal 90–250 VAC power input, enhanced hardware configuration, special relay function setting, default communication parameters and standard enclosure without custom modifications.System Compatibility: 3300 XL proximity probes, velocity transducers, ICP accelerometers, Type E/J/K/T thermocouples, Pt100/Pt1000 RTDs, Modbus RTU-enabled DCS, SCADA and PLC systems
Country of Origin: United States
Main Components: Main monitor module, integrated LCD display, tactile keypad and multi-status LED indicators
Electrical Characteristics
Power Supply: 90 VAC to 250 VAC, 50/60 Hz, universal industrial AC input defined by the first
-01codePower Consumption: Maximum 15 W under full-load operating status
Signal Processing: 24-bit high-precision ADC for all input channels, supporting wide frequency bandwidth and high-fidelity signal conversion
Input Channels: Four universal transducer inputs configurable for proximity, velocity, acceleration and Keyphasor signals; four dedicated temperature inputs compatible with 2-wire and 3-wire RTDs and multiple types of thermocouples
Output Interfaces: Six programmable SPDT relay outputs with custom relay logic per the
-03code; four galvanically isolated 4–20 mA analog outputs; one buffered raw signal output for external vibration analysis and on-site troubleshootingCommunication Interface: RS-485 Modbus RTU, adjustable baud rate from 9600 bps to 115200 bps
Electrical Isolation: Complete galvanic isolation between power loop, signal inputs, outputs and communication ports to eliminate ground loop and electromagnetic interference
Physical and Mechanical
Enclosure: Reinforced metal housing with EMI shielding. Internal PCB is coated with conformal coating to resist dust, moisture and mild chemical corrosion.
Mounting: Standard 35 mm DIN rail mounting, also compatible with panel installation.
Terminals: Removable screw terminal blocks, supporting 12 AWG to 22 AWG field wiring for convenient connection and maintenance.
Human-Machine Interface: Built-in LCD screen for real-time data viewing and parameter configuration; LED indicators display power status, normal operation, alarm and fault conditions clearly.
Ingress Protection: IP20 rating for standard indoor cabinet installation.
Environmental Limits
Operating Temperature: -20 °C to +70 °C
Storage Temperature: -30 °C to +90 °C
Relative Humidity: 5% to 95% RH, non-condensing environment
Vibration Resistance: Withstands continuous 5 g vibration within 10 Hz to 1 kHz frequency range
Shock Resistance: Tolerates 10 g transient mechanical shock
Compliance and Certification
Applicable Standards: API 670, ISO 10816, IEC 61000-6-2, IEC 61000-6-4
Certifications: CE, cULus, ATEX Zone 2, RoHS and ABS marine certification
Hazardous Area Rating: Class I Division 2 / Zone 2, Temperature Class T4, suitable for non-incendive hazardous industrial locations
Quality Control: Manufactured in accordance with ISO 9001 quality management system. Every unit is fully calibrated and functionally tested before delivery.
Lifecycle Status: In active production, with full technical support for new projects, system expansion and equipment retrofits.
3. Function and Product Positioning
Core Functions
Multi-Parameter Comprehensive Monitoring: Simultaneously measures shaft radial vibration, axial thrust displacement, rotational speed, phase and bearing/process temperature to realize full-condition monitoring of rotating machinery.
Flexible Signal Processing: Each transducer channel supports multiple sensor types, equipped with configurable high-pass and low-pass filters as well as signal scaling functions to adapt to diverse field measurement demands.
Customized Relay Alarm & Interlock: Featured with special relay logic defined by the
-03code. Six relays can realize complex alarm grouping, interlock and sequential control beyond standard settings, meeting customized protection requirements. Each channel supports independent Alert and Danger thresholds with adjustable hysteresis.Intelligent Fault Diagnosis & Event Logging: Automatically detects sensor open circuit, short circuit and signal anomalies. The non-volatile memory stores up to 200 time-stamped event records for fault tracing, routine maintenance and compliance auditing.
Data Interconnection: Modbus RTU uploads real-time data to plant control systems; isolated 4–20 mA analog outputs connect to recorders and DCS analog channels for data distribution.
Local Operation: Onboard display and keypad support on-site data checking, parameter setting and alarm reset without additional configuration software.
Operational Features
Universal AC Power: Compatible with global industrial AC voltage range, no external adapter needed for direct power connection.
Enhanced Hardware Design: Optimized circuit structure improves anti-vibration and anti-interference performance, adapting to complex industrial electromagnetic environments.
Custom Relay Logic: Factory preset special relay assignment and action logic, ideal for sites with customized interlock and alarm rules.
Wide Sensor Compatibility: Fully compatible with full range of Bently Nevada 3300 XL sensors, and supports mainstream third-party industrial sensors via parameter adjustment.
Hot-Swap Capability: Allows on-site replacement during normal system operation to reduce downtime.
Data Security: Configuration data and event logs are stored in non-volatile memory, with no data loss after power failure.
Product Positioning
4. Core Performance Parameters
Measurement Performance
Transducer Channels: Frequency response 0 Hz to 10 kHz; supports vibration displacement, velocity and acceleration measurement
Temperature Channels: Thermocouple range -200 °C to +1300 °C; RTD range -200 °C to +850 °C
Measurement Accuracy: ±0.1% full scale for transducer inputs; ±0.5 °C for temperature inputs
Repeatability: Better than ±0.05% full scale
Filter Options: Configurable 4-pole to 8-pole high-pass and low-pass filters
Output Performance
Relay Specifications: 5 A rated current at 30 VDC; normally open and normally closed contacts configurable with custom action logic
Analog Output: 4–20 mA isolated output, maximum load 500 Ω, output accuracy ±0.1% full scale
Communication: Modbus RTU protocol, supports up to 247 slave devices on a single RS-485 network
Reliability
MTBF: More than 150,000 hours under standard 25 °C operating environment
Warranty: 1-year standard factory warranty, extended warranty available
Maintenance: No mandatory routine maintenance; annual calibration verification and visual inspection are recommended
5. General Matching Accessories
Installation and Mounting Accessories
Standard 35 mm DIN rail mounting hardware (included)
Optional panel mounting adapter plate
External protective enclosure for dusty and humid working areas
Spare terminal blocks and display components
Compatible System Products
3300 XL series proximity probes and matched extension cables
Industrial velocity sensors and ICP accelerometers
Standard thermocouples and Pt100/Pt1000 RTD sensors
Modbus RTU based DCS, PLC and remote monitoring terminals
Maintenance and Spare Parts
Official 1900 Series configuration software
Calibration verification tools
Conformal coating repair materials
Factory calibration report and full test documents (included upon delivery)
Supporting Documentation
Dedicated datasheet and installation manual for 1900/65A-01-01-03-00-00
1900 Series overall application guide
Modbus RTU communication protocol specification
API 670 application guideline for auxiliary machinery monitors
6. Applicable Equipment and Industry Fields
Primary Applications
Power Generation: Auxiliary pumps, cooling fans, blowers and small compressors in thermal power and combined-cycle power plants
Oil and Gas: Refinery fans, offshore platform pumps, auxiliary compressors and pipeline conveying equipment
Petrochemical: Process pumps, cooling tower fans, agitators and transmission gear units on chemical production lines
Secondary Applications
Water and Wastewater Treatment: Large water supply pumps, aeration blowers and processing fans
Pulp and Paper Industry: Paper machine drive fans, material pumps and auxiliary transmission equipment
Marine and Offshore: Vessel auxiliary pumps, ventilation fans and non-critical rotating equipment on offshore platforms
Compatibility Notes
Power Requirement: Designed for 90–250 VAC input. Do not connect to DC power beyond specification range.
Sensor Matching: Must be used with 3300 XL series proximity probes; incompatible with old non-XL 3300 sensors.
Relay Logic: The unit is factory set with special relay rules; reconfigure carefully if on-site logic needs adjustment.
Network Setting: Assign unique Modbus slave address for each unit on the same network to avoid communication conflicts.
Hazardous Area Use: When applied in Class I Division 1 hazardous areas, install certified external safety barriers between sensors and the monitor.