Product Specification Document: Bently Nevada 1900/65A-01-01-01-00-00
Description
Product Specification Document: Bently Nevada 1900/65A-01-01-01-00-00
1. Product Overview
2. Basic Product Information
Manufacturer and Model Identity
Manufacturer: Bently Nevada, a Baker Hughes company
Model Number: 1900/65A-01-01-01-00-00
Product Series: 1900 Cordant Series General Purpose Equipment Monitor
Product Type: Standalone Multi-Channel Machinery Condition Monitor
Model Code Definition: The full suffix
-01-01-01-00-00stands for universal AC power supply, enhanced hardware configuration, standard relay logic, default communication settings and no custom enclosure options.System Compatibility: 3300 XL proximity probes, velocity transducers, ICP accelerometers, Type E/J/K/T thermocouples, Pt100/Pt1000 RTDs, Modbus RTU-enabled DCS, SCADA and PLC systems
Country of Origin: United States
Main Components: Main monitor assembly, integrated LCD display, tactile keypad and multi-functional LED status indicators
Electrical Characteristics
Power Supply: 90 VAC to 250 VAC, 50/60 Hz, universal industrial AC input as defined by the
-01power codePower Consumption: Maximum 15 W under full load operating conditions
Signal Processing: 24-bit high-resolution ADC for all input channels, supporting wide frequency bandwidth and accurate signal conversion
Input Channels: Four universal transducer inputs configurable for proximity, velocity, acceleration and Keyphasor signals; four dedicated temperature inputs compatible with common industrial thermocouples and 2/3-wire RTD sensors
Output Interfaces: Six programmable SPDT relay outputs with standard alarm interlock logic; four galvanically isolated 4–20 mA analog outputs; one buffered raw signal output for external vibration analysis and troubleshooting
Communication: RS-485 Modbus RTU interface, adjustable baud rate ranging from 9600 bps to 115200 bps
Isolation Design: Complete galvanic isolation between power circuits, input signals, output circuits and communication ports to eliminate ground loop interference
Physical and Mechanical
Enclosure: Heavy-duty metal housing with EMI shielding. Internal printed circuit board is protected by conformal coating against dust, moisture and mild chemical corrosion.
Mounting: Standard 35 mm DIN rail mounting, also suitable for direct panel installation.
Terminals: Removable screw terminal blocks, supporting 12 AWG to 22 AWG field wiring for easy wiring and maintenance.
Human-Machine Interface: Built-in LCD screen for real-time data display and parameter setup; LED indicators clearly show power status, normal operation, alarm and fault conditions.
Ingress Protection: IP20 rating for standard indoor industrial cabinet installation.
Environmental Limits
Operating Temperature: -20 °C to +70 °C
Storage Temperature: -30 °C to +90 °C
Relative Humidity: 5% to 95% RH, non-condensing environment
Vibration Resistance: Withstands continuous 5 g vibration within 10 Hz to 1 kHz frequency range
Shock Resistance: Tolerates 10 g transient mechanical shock
Compliance and Certification
Applicable Standards: API 670, ISO 10816, IEC 61000-6-2 and IEC 61000-6-4
Certifications: CE, cULus, ATEX Zone 2, RoHS and ABS marine certification
Hazardous Area Rating: Class I Division 2 / Zone 2, Temperature Class T4, applicable for non-incendive hazardous industrial locations
Quality Control: Manufactured under ISO 9001 quality management system. Every unit undergoes full functional calibration and testing before delivery.
Lifecycle Status: Actively produced and fully supported for new projects, system expansion and equipment retrofits.
3. Function and Product Positioning
Core Functions
Full-Scope Multi-Parameter Monitoring: Simultaneously measures shaft radial vibration, axial thrust displacement, rotational speed, phase and equipment temperature to realize all-round condition monitoring of rotating machinery.
Flexible Signal Configuration: Each transducer channel can be switched to match different sensor types. Configurable high-pass and low-pass filters as well as signal scaling functions adapt to diverse field measurement requirements.
Hierarchical Alarm Management: Independent Alert and Danger setpoints for each channel with adjustable hysteresis. Six relays can be assigned for alarm indication or equipment shutdown interlock according to on-site demands.
Intelligent Fault Diagnosis & Event Logging: Automatically detects sensor open circuit, short circuit and signal anomalies. The built-in non-volatile memory stores up to 200 time-stamped events for fault tracing, maintenance analysis and compliance records.
Data Interconnection: Modbus RTU realizes real-time data upload to plant control systems. Isolated 4–20 mA outputs connect to recorders and DCS analog channels for data distribution.
Local Operation: Onboard display and keypad support on-site data viewing, parameter configuration and alarm reset without extra software or tools.
Operational Features
Universal AC Power Compatibility: The
-01power configuration fits global industrial AC voltage standards, requiring no external power adapter for direct connection.Enhanced Hardware Performance: The
-01hardware option optimizes circuit design for stronger anti-vibration and anti-electromagnetic interference ability, suitable for complex industrial field environments.Outstanding Sensor Compatibility: Fully compatible with the complete range of Bently Nevada 3300 XL sensors, and supports mainstream third-party industrial sensors via parameter adjustment.
Hot-Swap Capability: The unit can be replaced during normal system operation to reduce equipment downtime and maintenance impact.
Data Security: All configuration parameters and event logs are stored in non-volatile memory, ensuring no data loss after power interruption.
Product Positioning
4. Core Performance Parameters
Measurement Performance
Transducer Channels: Frequency response from 0 Hz to 10 kHz; supports vibration displacement, velocity and acceleration measurement
Temperature Channels: Thermocouple measuring range -200 °C to +1300 °C; RTD measuring range -200 °C to +850 °C
Measurement Accuracy: ±0.1% of full scale for transducer inputs; ±0.5 °C for temperature inputs
Repeatability: Better than ±0.05% of full scale
Filter Options: Configurable 4-pole to 8-pole high-pass and low-pass filters
Output Performance
Relay Specifications: Rated 5 A at 30 VDC; normally open and normally closed contacts are configurable
Analog Output: 4–20 mA isolated output, maximum load 500 Ω, output accuracy ±0.1% full scale
Communication Performance: Modbus RTU protocol, supports up to 247 slave devices on a single RS-485 network
Reliability
MTBF: More than 150,000 hours under standard 25 °C operating environment
Warranty: 1-year standard factory warranty, extended warranty services are available
Maintenance: No mandatory routine maintenance. Annual calibration verification and visual inspection are recommended for long-term operation.
5. General Matching Accessories
Installation and Mounting Accessories
Standard 35 mm DIN rail mounting hardware (included)
Optional panel mounting adapter plate
External protective enclosure for dusty or open-air installation
Spare terminal blocks and display components
Compatible System Products
3300 XL series proximity probes and matched extension cables
Industrial velocity sensors and ICP accelerometers
Standard thermocouples and Pt100 RTD sensors
Modbus RTU-based DCS, PLC and remote monitoring terminals
Maintenance and Spare Parts
Official 1900 Series configuration software
Calibration verification tools
Conformal coating repair materials
Factory calibration report and full test documents (included with delivery)
Supporting Documentation
Dedicated datasheet and installation manual for 1900/65A-01-01-01-00-00
1900 Series overall application guide
Modbus RTU communication protocol specification
API 670 application guideline for auxiliary machinery monitors
6. Applicable Equipment and Industry Fields
Primary Applications
Power Generation: Auxiliary water pumps, cooling fans, blowers and small compressors in thermal power and combined-cycle power plants
Oil and Gas: Refinery fans, offshore platform pumps, auxiliary compressors and pipeline conveying equipment
Petrochemical: Process pumps, cooling tower fans, agitators and transmission gear units on chemical production lines
Secondary Applications
Water and Wastewater Treatment: Large water supply pumps, aeration blowers and processing fans
Pulp and Paper: Paper machine drive fans, stock pumps and auxiliary transmission equipment
Marine and Offshore: Vessel auxiliary pumps, ventilation fans and non-critical rotating equipment on offshore platforms
Compatibility Notes
Power Requirement: This model is designed for 90–250 VAC input. Do not connect to DC power outside the specified range.
Sensor Matching: Must be used with 3300 XL series proximity probes; incompatible with old-style non-XL 3300 sensors.
Network Setting: Assign a unique Modbus slave address to each unit when multiple monitors are connected on one network to avoid communication conflicts.
Hazardous Area Installation: When deployed in Class I Division 1 hazardous areas, install certified external safety barriers between sensors and the monitor.
Get a Quote