Product Specification Document: Bently Nevada 1900/65A-01-00-01-00-00
Description
Product Specification Document: Bently Nevada 1900/65A-01-00-01-00-00
1. Product Overview
2. Basic Product Information
Manufacturer and Model Identity
Manufacturer: Bently Nevada, Baker Hughes
Model Number: 1900/65A-01-00-01-00-00
Product Series: 1900 Cordant Series General Purpose Equipment Monitor
Product Type: Standalone Multi-Parameter Machinery Monitor
Model Code Explanation: The suffix
-01-00-01-00-00represents standard AC power supply configuration, no special hardware modification, standard relay definition, default communication and enclosure options.System Compatibility: 3300 XL proximity probes, velocity transducers, ICP accelerometers, standard thermocouples and RTD sensors; Modbus RTU compatible DCS, SCADA and PLC systems
Country of Origin: United States
Main Components: Main monitor unit, integrated LCD display, tactile operation keypad and status indicator LEDs
Electrical Characteristics
Power Supply: 90 to 250 VAC, 50/60 Hz, factory configured for universal AC input per the
-01codePower Consumption: Maximum 15 W under full load operation
Signal Acquisition: 24-bit high-precision ADC for all input channels, ensuring stable and accurate signal conversion
Input Channels: Four configurable transducer inputs for proximity, velocity, acceleration and Keyphasor signals; four temperature inputs supporting Type E, J, K, T thermocouples and 2-wire / 3-wire Pt100 / Pt1000 RTDs
Output Interfaces: Six programmable SPDT relay outputs with standard alarm logic; four isolated 4–20 mA analog outputs; one buffered raw signal output for external analysis
Communication Interface: RS-485 Modbus RTU, configurable baud rate from 9600 bps to 115200 bps
Electrical Isolation: Galvanic isolation between input, output, power and communication ports to prevent ground loop interference
Physical and Mechanical
Enclosure: Reinforced metal housing with EMI shielding; internal PCB coated with conformal coating for dust, moisture and chemical resistance
Mounting Mode: Standard 35 mm DIN rail mounting, also applicable for panel installation
Terminals: Removable screw terminal blocks, compatible with 12 AWG to 22 AWG field wiring
Human-Machine Interface: Built-in LCD screen for real-time data display and parameter setting; multi-color LED indicators for power, running status, alarm and fault prompts
Ingress Protection: IP20 for standard indoor installation
Environmental Limits
Operating Temperature Range: -20 °C to +70 °C
Storage Temperature Range: -30 °C to +90 °C
Relative Humidity: 5% to 95%, non-condensing environment
Vibration Resistance: Withstands 5 g continuous vibration within 10 Hz to 1 kHz frequency range
Shock Resistance: Tolerates 10 g transient mechanical shock
Compliance and Certification
Applicable Standards: API 670, ISO 10816, IEC 61000-6-2, IEC 61000-6-4
Certifications: CE, cULus, ATEX Zone 2, RoHS and marine ABS certification
Hazardous Area Rating: Class I Division 2 / Zone 2, temperature class T4, suitable for non-incendive hazardous industrial areas
Quality Management: Manufactured in accordance with ISO 9001 quality system, 100% factory calibration and functional testing before delivery
Lifecycle Status: In active production, providing complete technical support and after-sales service for new projects and equipment retrofits
3. Function and Product Positioning
Core Functions
Multi-Parameter Integrated Monitoring: Collect real-time data including shaft radial vibration, axial thrust displacement, rotational speed, phase and bearing temperature to realize full-condition monitoring of rotating equipment.
Flexible Signal Processing: Each transducer channel can be switched to match different types of sensors, equipped with configurable filters and signal scaling functions to adapt to various measurement requirements.
Hierarchical Alarm Management: Independent Alert and Danger alarm thresholds for each channel with adjustable hysteresis; six relays can be flexibly assigned to alarm indication or equipment interlock protection according to on-site demands.
Fault Diagnosis and Event Recording: Automatic detection of sensor disconnection, short circuit and signal abnormality; built-in non-volatile event log records alarms, faults and operation records with time stamps for equipment maintenance and fault tracing.
Data Interconnection: Modbus RTU communication realizes data upload to the plant control system; 4–20 mA analog outputs connect to recorders and DCS analog channels to complete data distribution.
Local Operation: The integrated display and keypad support on-site viewing of operating data, parameter configuration and alarm reset without additional configuration tools.
Operational Features
Universal AC Power Supply: The
-01power configuration adapts to global industrial AC voltage standards, no external power adapter required for direct connection to on-site AC power distribution.Standard Default Settings: Factory preset standard relay logic and communication parameters, realizing plug-and-play for conventional application scenarios.
Strong Sensor Compatibility: Fully compatible with full series of Bently Nevada 3300 XL sensors, and supports third-party standard industrial sensors through parameter adjustment.
Hot-swap Support: Field replacement of the unit is allowed under normal operating conditions to reduce equipment downtime.
Data Security: Configuration data and event logs are stored in non-volatile memory, and data will not be lost after power failure.
Product Positioning
4. Core Performance Parameters
Measurement Performance
Transducer Input: Frequency response range 0 Hz to 10 kHz; supports vibration displacement, velocity and acceleration measurement
Temperature Input: Thermocouple measuring range -200 °C to +1300 °C; RTD measuring range -200 °C to +850 °C
Overall Measurement Accuracy: ±0.1% full scale for transducer channels; ±0.5 °C for temperature channels
Repeatability: Better than ±0.05% full scale
Filter Function: Configurable 4-pole to 8-pole high-pass and low-pass filters
Output Performance
Relay Parameters: Rated 5 A at 30 VDC, normally open and normally closed contacts configurable
Analog Output: 4–20 mA isolated output, maximum load 500 Ω, output accuracy ±0.1% full scale
Communication: Modbus RTU protocol, supports up to 247 slave devices on a single network
Reliability
Mean Time Between Failures: Over 150,000 hours under 25 °C normal operating environment
Warranty: 1 year standard factory warranty, extended warranty available
Maintenance: No mandatory regular maintenance; annual calibration verification and visual inspection are recommended
5. General Matching Accessories
Installation and Mounting Accessories
Standard 35 mm DIN rail mounting parts
Optional panel mounting adapter plate
Protective enclosure for outdoor or harsh dust environment
Replacement terminal blocks and display components
Compatible System Products
3300 XL series proximity probes and matching cables
Industrial velocity sensors and ICP accelerometers
Standard industrial thermocouples and Pt100 RTD sensors
Modbus RTU based DCS, PLC and remote monitoring terminals
Maintenance and Spare Parts
Official 1900 series configuration software
Calibration inspection tools
Conformal coating maintenance materials
Factory calibration report and test documents
Supporting Documentation
1900/65A-01-00-01-00-00 dedicated datasheet and installation manual
1900 series system application guide
Modbus RTU communication protocol specification
API 670 implementation guide for auxiliary machinery monitors
6. Applicable Equipment and Industry Fields
Primary Applications
Power Generation Industry: Auxiliary pumps, cooling fans, blowers and small compressors in thermal power, combined cycle power plants
Oil and Gas Industry: Refinery fans, platform water pumps, auxiliary compressors and pipeline conveying equipment
Petrochemical Industry: Process pumps, cooling tower fans, agitators and transmission gear units on chemical production lines
Secondary Applications
Water and Wastewater Treatment: Large water supply pumps, aeration blowers and processing fans
Pulp and Paper Industry: Drive fans, material pumps and auxiliary transmission equipment of paper machines
Marine Industry: Ship auxiliary pumps, ventilation fans and offshore platform non-critical rotating equipment
Compatibility Notes
Power Matching: This model is designed for 90–250 VAC power supply, do not connect to DC power beyond the specification range.
Sensor Matching: It must be used with 3300 XL series proximity probes, and is not compatible with old non-XL 3300 sensors.
Network Setting: When multiple units are connected to Modbus network, set independent slave addresses for each device to avoid communication conflict.
Hazardous Area Use: When applied in Class I Division 1 hazardous areas, external certified safety barriers must be equipped between sensors and the monitor.
Get a Quote