1900/17 Proximitor® Monitor
Description
✅ Model Explanation 1900/17‑XX
1900/17: Basic model (single-channel Proximitor monitor)
XX (power / options)
00: 24VDC, no additional options
01: 115/230VAC
03: 24VDC + intrinsically safe (IS)
Common order number: 148680-01
✅ Technical parameters
Mechanical characteristics
Structure: Independent wall-mounted
Dimensions (height × width × depth): 196mm × 160mm × 108mm
Weight: Approximately 1.2kg
Protection: IP20 (front panel) Input
Channel: 1 electrical eddy current (Proximitor) input
Adapter sensor: 3300XL series (offset -24VDC)
Measurement: Shaft displacement (peak-to-peak)
Frequency response: 10Hz – 10kHz
Range: 0 – 250μm (0 – 10mil), selectable by software
Accuracy: ±1% of full scale Output
Relay: 2×DPDT (Alarm / Danger), 5A @ 250VAC/30VDC
Buffer output: BNC (original probe signal)
4-20mA analog output (1900/15 not included, core difference)
Power supply and environment
Power supply: 24VDC (18–30VDC) or 115/230VAC (50/60Hz)
Power consumption: Approximately 10W
Operating temperature: -40°C ~ +70°C
Humidity: 5%–95% RH (no condensation)
Status LED: OK, Alert, Danger, Fault Communication
Built-in TIM interface: Compatible with Trendmaster®2000 system
No Modbus/Ethernet (local monitoring type)
✅ Core functions
Single-channel displacement monitoring: Combined with 3300XL probe, measures shaft vibration / axial displacement
Dual threshold alarm: Independent warning (Alert), danger (Danger), with delay ranging from 0.1 to 30 seconds
Local display and diagnosis: LCD real-time value + LED status; probe disconnection / short circuit / over-range detection
Independent / dual-purpose for local or Trendmaster®2000 connection: Local protection or connection to Trendmaster®2000
Key upgrades: Comes with 4-20mA output, can be directly connected to DCS/PLC, no additional modules required
✅ Application scenarios
General industry: pumps, fans, small motors (shaft displacement monitoring)
Oil and gas: auxiliary equipment, non-critical compressors
Power: cooling tower pumps, boiler fans, small steam turbines
Renovation projects: Replace old single-channel monitors, prioritize 1900/17 when 4-20mA signal is required