1900/15 Vibration Monitor (Bently Nevada)
Description
Model Interpretation
1900/15‑XX
1900/15: Base model (single‑channel proximitor/displacement monitor)
XX (Power & Options):
00: 24 VDC power, no extra options
01: 115/230 VAC power
03: 24 VDC + intrinsically safe (IS) barriers
Common part number: 148679‑01.
Technical Parameters
Mechanical
Form Factor: Standalone, wall‑mount
Dimensions (H×W×D): 196 mm × 160 mm × 108 mm
Weight: ~1.2 kg
Enclosure: Industrial plastic, IP20 (front)
Inputs
Channel: 1 dynamic input (proximitor/eddy‑current)
Sensor Compatibility: Bently Nevada 3300XL series (−24 VDC bias)
Measurement: Shaft displacement (peak‑to‑peak)
Frequency Response: 10 Hz–10 kHz
Range: 0–250 μm (0–10 mils), software‑selectable
Accuracy: ±1% FS
Outputs
Relays: 2 × DPDT (Alert, Danger); 5 A @ 250 VAC / 30 VDC
Buffered Output: BNC (raw proximitor signal)
No 4–20 mA analog output (use 1900/27 if 4–20 mA is needed)
Power & Environmental
Power: 24 VDC (18–30 VDC) or 115/230 VAC (50/60 Hz)
Power Consumption: ~10 W
Operating Temp: −40°C to +70°C
Humidity: 5%–95% RH, non‑condensing
Status LEDs: OK, Alert, Danger, Fault
Communications
Built‑in TIM: For Trendmaster® 2000 system connection
No Modbus/Ethernet (simple local monitor)
Core Functions
Single‑Channel Displacement Monitoring: Measures shaft vibration/runout via eddy‑current probe.
Dual Alarm Thresholds: Independent Alert (warning) and Danger (trip) with delay (0.1–30 s).
Local Indication: LCD display for real‑time value; LED status lights.
Sensor Diagnostics: Detects open/short circuit, fault, out‑of‑range.
Standalone or System Use: Local protection or integration with Trendmaster® 2000.
Compact & Low‑Cost: Ideal for basic monitoring points without multi‑parameter needs.
Applications
General Industry: Pumps, fans, blowers, small motors (shaft displacement monitoring).
Oil & Gas: Auxiliary equipment, non‑critical compressors.
Power: Cooling tower pumps, boiler fans, small turbines.
Retrofit Projects: Replaces old single‑channel monitors; easy field installation.
Usage & Maintenance
Installation: Wall‑mount; wire 3300XL probe to rear terminals; connect power.
Configuration: Set range, alarm thresholds via DIP switches or local buttons.
Maintenance: Annual wiring inspection; no routine calibration required.
Compatibility: Works exclusively with Bently Nevada 3300XL proximitor sensors.
Get a Quote