1900/65A General Purpose Equipment Monitor (Bently Nevada)
Description
Model Interpretation
1900/65A: Base model (general‑purpose equipment monitor)
1st XX (Power):
00: 24 VDC
01: 115/230 VAC
2nd XX (Communications):
00: No comms
01: Modbus (RS‑485)
02: Modbus/TCP (Ethernet)
3rd XX (Relays):
00: 6 relays (standard)
03: 6 relays + intrinsically safe (IS) barriers
4th XX (Approvals):
00: None
01: CSA/NRTL/C
02: ATEX/IECEx (Zone 2)
5th XX (Display):
00: Standard LCD
Common part numbers: 167699‑02, 1900/65A‑01‑02‑00‑01‑00.
Technical Parameters
Mechanical
Form Factor: Standalone, wall‑mountable
Dimensions (H×W×D): 196 mm × 160 mm × 108 mm
Weight: ~1.36 kg
Enclosure: Industrial plastic, IP20 (front)
Inputs
Dynamic Inputs (4 Ch):
Proximity (eddy‑current): 3300XL series, −24 VDC bias
Velomitor (velocity): 100 mV/in/s
Accelerometer (acceleration): 2‑wire/3‑wire, 100 mV/g
Keyphasor (speed): TTL/HTL, 1–10,000 RPM
Frequency Response: 0.5 Hz–25 kHz; 4‑pole HP/LP filters
Temperature Inputs (4 Ch):
Thermocouple: E, J, K, T
RTD: 2‑wire/3‑wire Pt100
Resolution: 24‑bit ADC; Accuracy: ±1% FS
Measurement Ranges
Vibration (Displacement): 0–500 μm (0–20 mils)
Vibration (Velocity): 0–50 mm/s (0–2 in/s)
Vibration (Acceleration): 0–50 g (peak)
Speed: 1–10,000 RPM
Temperature: −200°C to +850°C (sensor‑dependent)
Outputs
Relays: 6 × DPDT, 5 A @ 250 VAC / 30 VDC (resistive); programmable Alert/Danger/OK logic
4–20 mA Analog: 4 channels (scaled to any input variable)
Buffered Sensor Outputs: 4 × BNC (raw signal, short‑circuit protected)
Event Log: 200‑entry (time‑stamped alarms/faults)
Power & Environmental
Power: 24 VDC (18–30 VDC) or 115/230 VAC (50/60 Hz)
Power Consumption: ~15 W
Operating Temp: −40°C to +70°C
Storage Temp: −40°C to +85°C
Humidity: 5%–95% RH, non‑condensing
Status LEDs: OK, Alert, Danger, Fault
Communications
Serial: RS‑232/485 (Modbus RTU)
Ethernet: Modbus/TCP (optional)
Software: 1900 Configuration Software (v5.0+); System 1 compatible
Core Functions
Multi‑Input Integration: Combines vibration, position, speed, and temperature in one unit (no separate modules).
4 Dynamic + 4 Temperature Channels: Flexible mapping for motors, pumps, fans, and compressors.
Dual Alarm Thresholds: Independent Alert (warning) and Danger (trip) per channel with 0.1–30 s delay (prevents false trips).
6 Programmable Relays: Map any channel’s status to relays for local annunciation or ESD.
4–20 mA Scaled Outputs: Direct interface with DCS/PLC for remote monitoring.
Buffered BNC Outputs: Raw sensor signals for oscilloscope diagnostics.
Built‑In Diagnostics: Sensor/cable fault detection, over/under‑range, and module self‑check.
Standalone Operation: No rack required; wall‑mountable for field installation.
Modbus Connectivity: Integrates with SCADA/System 1 for centralized monitoring.
Applications
Oil & Gas: Pumps, fans, blowers, and small compressors (non‑critical rotating equipment).
Power Generation: Auxiliary motors, boiler fans, and cooling tower pumps.
Petrochemical/Refining: General‑purpose machinery (mixers, agitators, conveyors).
Water/Wastewater: Centrifugal pumps, aeration blowers.
Manufacturing: Machine tools, conveyors, and material handling equipment.
HVAC: Large fans and chillers in commercial buildings.
Usage & Maintenance
Installation: Wall‑mount; wire sensors to rear terminals; connect power and comms.
Configuration: Use 1900 Software; set channel type, range, thresholds, and output scaling.
Maintenance: Inspect wiring annually; calibrate every 2–3 years; no internal consumables.
Compatibility: Replaces legacy 1900/65; compatible with 3300/3300XL sensors and System 1 software。
Get a Quote