3500/33 16-Channel Relay Module (Bently Nevada)
Description
Model Interpretation
3500/33‑AXX‑BXX
3500/33: Base model (16‑channel relay module)
AXX: Isolation type
01: Non‑isolated
02: Isolated
BXX: Approvals
00: None
01: CSA/NRTL/C
02: ATEX/IECEx/CSA (Zone 2)
Common part numbers: 149986‑01, 162291‑01.
Technical Parameters
Mechanical
Form Factor: Full‑height, single‑slot
Dimensions (H×W×D): 241 mm × 24.4 mm × 242 mm
Weight: ~0.7 kg
Installation: Full‑height slot right of TDI in 3500/05 rack
Relay Outputs (16 channels)
Type: Form‑C (SPDT), epoxy‑sealed, arc suppression (250 Vrms)
Rating: 5A @ 250 VAC / 30 VDC (resistive load)
Contact Life: ≥10,000,000 cycles
Response Time: ≤15 ms
Logic: AND/OR/voting/latch per channel; 100 ms update rate
Power & Environmental
Power Consumption: ~5.8 W (from rack backplane, −24 VDC)
Operating Temp: −30°C to +65°C
Storage Temp: −40°C to +85°C
Humidity: 5%–95% non‑condensing
Vibration/Shock: 3 g (5–100 Hz), 10 g (11 ms)
Status LEDs: OK + 16 channel alarm LEDs (front panel)
Core Functions
Provide 16 independent, software‑configurable relay outputs for alarms, trips, and interlocks.
Support complex voting logic (AND/OR/2‑out‑of‑3) using any rack monitor’s Alert/Danger/OK signals.
Enable high‑density I/O for large systems, reducing rack space vs. multiple 3500/32 modules.
Arc suppression extends contact life and protects circuits.
Hot‑swappable (with redundant rack power) for replacement without shutdown.
Interface with DCS/PLC/ESD via dry contacts for seamless integration.
Applications
Power Generation: Steam/gas turbines, generators (multiple trip/alarm points).
Oil & Gas: Compressors, pumps, blowers (complex interlock & ESD logic).
Petrochemical/Refining: Critical rotating machinery (multi‑channel alarm annunciation).
Heavy Industry: Pulp & paper, mining (large asset protection with many I/O).
Safety Systems: SIS/ESD requiring voting‑based trip logic.
Usage & Maintenance
Installation: Insert into full‑height slot right of TDI; wire rear terminals to field devices.
Configuration: Use 3500 Configuration Software (v3.3+); set logic, sources, and contact state.
Maintenance: Inspect connectors annually; no consumables.
Status: Active; supported by Baker Hughes with full spare parts availability.
Get a Quote