Description

SAIA-BURGESS PCD3.E160: PCD3 16-Channel Digital Input Module Product Description

Brand and Product Identification

The SAIA-BURGESS PCD3.E160 is a digital input module for the Saia PCD3 programmable controller family. The PCD3 prefix identifies the PCD3 controller platform, E160 identifies a 16-channel digital input module with ribbon cable connector, and the D connector type identifies the module I/O connection arrangement. The PCD3.E160 belongs to the PCD3.Exxx digital input module group used with PCD3 CPU base units, module holders or remote I/O expansion stations. The module reads 24 V DC field digital signals and transfers their state to the PCD3 PLC program through the PCD3 module bus.

Product Function and System Role

The PCD3.E160 converts field switch, sensor or contact signals into digital input states readable by the PCD3 controller. The 16 electrically connected input channels accept source or sink operation, and input signals are wired to the module through the ribbon cable or terminal adapter arrangement. The module conditions and filters input signals so the PLC program can read pushbuttons, limit switches, proximity switches, relay contacts, valve position feedback and other on-off field devices. It is a digital input module, not a digital output module, analog module, relay output module, communication module, PLC CPU or field sensor.

Input Specifications

The module has 16 digital inputs. Input voltage is 24 V DC within the range 15 to 30 V DC, smoothed or pulsed. Input current is 4 mA per input at 24 V DC according to the published module specifications. Input delay is typically 8 ms for the E160 version. Inputs support source or sink operation. Electrical isolation for the E160 input group is type D according to the PCD3 module table; detailed isolation rating should be verified from the PCD3 I/O module manual for the connected field circuit.

Current Draw and Bus Connection

The PCD3.E160 internal current draw is listed as 10 mA for the internal bus in the PCD3 catalog data. The module draws current from the PCD3 internal 5 V and plus V 24 V module bus as calculated in the PG5 Device Configurator. The internal load current taken by I/O modules from the plus 5 V and plus V 24 V supply must not exceed the maximum supply current specified for the CPU, RIO or PCD3.C200 module holder. The module mounts as a cassette on the PCD3 base CPU or appropriate expansion holder.

Connector and Wiring Arrangement

The PCD3.E160 uses connector type D, associated with a 34-pin ribbon cable connector for system cables. Digital modules with 16 I/Os use system ribbon cables such as the PCD2.K221 sheathed round cable with 32 strands of 0.25 mm² and 1.5 m length, or the PCD2.K223 3.0 m version, according to the PCD3 accessory list. Plug-in I/O spring terminal blocks are available separately as accessories for terminal wiring, while ribbon cables and adapters are ordered separately. The circuit diagram printed on the side of the module supports wiring and commissioning.

Mechanical and System Compatibility

PCD3 I/O modules plug into the Saia PCD3 base CPU or an appropriate module holder. Expansion holders are available in two-slot or four-slot versions, and the PCD3 system can expand to a large number of I/O modules or remote I/O points using RIO PCD3.T66x or PCD3.T76x units. The E160 module dimensions listed by a distributor are approximately 3.2 cm width, 5.7 cm height and 10.8 cm depth; exact module mechanical data should be confirmed against the PCD3 hardware manual. The module is intended for control cabinet installation with the PCD3 controller.

Typical Application Scenarios

Typical applications include machine sequencing, conveyor control, packaging machines, assembly lines, material handling, process interlocks, pump or fan feedback, limit switch monitoring, pushbutton and selector switch reading, proximity switch inputs and remote I/O field signal acquisition. The 16 input channels suit digital on-off signals from discrete field devices in PCD3-based automation systems.

Installation and Configuration Notes

Installation should follow the Saia PCD3 I/O module manual, PG5 Controls Suite Device Configurator rules and local electrical codes. Plug the module into the correct PCD3 slot, connect the ribbon cable or terminal adapter, verify field device wiring, input voltage and source or sink configuration, and check bus current budget in the device configurator. Configure input addresses and module type in PG5 programming software, verify each input state against the field device, and check input delay and signal filtering for the application. When replacing an E160, confirm module suffix, connector type D, input count, voltage range and system cable compatibility.

Advantages and Selection Notes

The PCD3.E160 offers 16 digital inputs, 15 to 30 V DC input range, source or sink operation, 8 ms typical input delay, ribbon cable connector type D, low 10 mA bus current draw and compatibility with the PCD3 PLC module family. When selecting or replacing a module, confirm E160 versus E161 or other E-series input variant, input delay, channel count, connector type, bus current draw, wiring cable and PCD3 CPU or holder compatibility. The PCD3.E160 is a digital input module, not an output module, analog module, CPU, communication module, sensor or contactor; its role is to acquire 24 V DC digital field signals for the Saia PCD3 control system.


Get a Quote