Description
BANNER AT-FM-10K 60698 0704H14: DUO-TOUCH Two-Hand Control Safety Module Product Description
Brand and Product Identification
The BANNER AT-FM-10K, Banner Engineering product number 60698 and identification code 0704H14, is a DUO-TOUCH SG two-hand control safety module for machine safety applications. The AT-FM-10K model identifies the safety monitor module, 60698 is the Banner Engineering catalog item number, and 0704H14 is the unit or manufacturing identification reference. The module monitors two Banner STB self-checking optical touch buttons or two mechanical push buttons and provides redundant forced-guided safety output contacts for two-hand control systems.
Product Function and System Role
The AT-FM-10K monitors the simultaneous actuation of two two-hand control devices and enables the machine output only when both inputs are activated within the required simultaneity window. It uses diverse-redundant microcontrollers and two redundant forced-guided, mechanically linked output relays to control external machine control elements. The module includes an external device monitoring feedback input to supervise external machine control elements such as safety contactors. It is a safety control module, not a two-hand pushbutton, contactor, PLC, sensor or motor starter by itself.
Supply and Input Specifications
The AT-FM-10K operates at 24 V DC plus or minus 15 percent at 150 mA, using a SELV-rated supply according to EN IEC 60950 and NEC Class 2. It also operates at 24 V AC plus or minus 15 percent at 150 mA, 50 to 60 Hz plus or minus 5 percent, using an NEC Class 2 transformer. Outputs from the actuating devices must each be capable of switching 25 mA at 24 V DC nominal. The module does not contain an internal fuse, and a 500 mA slow-blow fuse in series with the plus 24 V AC/DC supply is highly recommended.
Safety Ratings and Performance
The AT-FM-10K is rated Category 4 and PL e according to EN ISO 13849-1, with MTTFd of 100 years. It is rated SIL 3 according to IEC 61508, with PFHd of 1.54 times 10 to the power of minus 9, and SIL CL 3 according to IEC 62061. It complies with Type IIIc requirements of EN ISO 13851 when used with STB touch buttons or hard contacts. The system meets two-hand control and control reliability requirements per OSHA 29 CFR 1910.217, NFPA 79 and ANSI B11.19.
Output Configuration and Contact Ratings
Each normally open output channel is a series connection of contacts from two forced-guided relays, K1 and K2. Contacts are AgNi with 5 µm gold plating. Low-current low-voltage switching ranges are 1 V AC/DC minimum to 60 V maximum, 5 mA AC/DC minimum to 300 mA maximum, and 5 mW or 5 mVA minimum to 7 W or 7 VA maximum. High-current ratings are 15 V AC/DC minimum to 250 V AC or 24 V DC at 6 A resistive maximum, with 30 mA AC/DC minimum current. IEC 60947-5-1 load ratings include AC15 at 230 V AC, 3 A and DC13 at 24 V DC, 2 A. Mechanical life is 20 million operations; electrical life depends on load and ranges from 150,000 cycles at 900 VA to 5 million cycles at 100 VA.
Response Time and Simultaneity
Maximum output response time is 35 milliseconds. The module monitors a simultaneity period of no more than 500 milliseconds for touch or push button operation. If the two inputs are not activated within this window, the module does not enable the safety output and the fault or input indication reflects the condition. The feedback, or EDM, input monitors external machine control elements and reports feedback error through the output LED and relay state.
Status Indicators
The AT-FM-10K has five indicator LEDs. Four green LEDs indicate Power ON, Input 1 energized, Input 2 energized and Output. One red LED indicates Fault. Power ON illuminates when power is applied. Fault illuminates when simultaneity is not met or an external wiring fault exists, and flashes to indicate an internal fault condition. Input status LEDs show button activation or flash for external wiring fault. The output LED illuminates when both relays K1 and K2 are energized and flashes for feedback error.
Mechanical Construction and Mounting
The safety module uses a polycarbonate housing rated IEC IP20 and mounts on a standard 35 mm DIN rail track. Dimensions are 22.5 mm width, 84.0 mm height and 118.0 mm depth, equivalent to 0.89 in width, 3.31 in height and 4.65 in depth. Removable terminal blocks simplify wiring and module replacement. The safety module must be installed inside an enclosure rated NEMA 3, or IEC IP54, or better; it is not designed for exposed wiring.
Typical Application Scenarios
Typical applications include presses, stamping machines, shears, press brakes, punch presses, injection molding machines, assembly presses and other machinery requiring two-hand control to prevent operator hand exposure to hazardous motion. The module can be paired with Banner STB optical touch buttons or mechanical two-hand pushbuttons. It supervises external safety contactors or machine control elements through the feedback input and provides redundant output contacts to stop or enable hazardous motion only under controlled two-hand operation.
Installation and Safety Commissioning Notes
Installation and commissioning must follow the AT-FM-10K product manual, local machinery safety standards and IEC/EN 60204-1 requirements. Install the module in the rated enclosure, mount it on the DIN rail, connect the 24 V AC/DC supply, two actuating device inputs, feedback input and redundant safety outputs. Use minimum 16 AWG to 18 AWG wire for power and output connections and minimum 20 AWG wire for other terminals. Provide a hand-operated supply disconnect and over-current protection per NFPA 79 and IEC/EN 60204-1. Verify input simultaneity, output relay operation, feedback monitoring and fault indication before placing the machine in service.
Advantages and Selection Notes
The AT-FM-10K offers diverse-redundant microcontroller monitoring, two forced-guided output relays, Type IIIc two-hand control compliance, Category 4 PL e and SIL 3 ratings, EDM feedback monitoring, LED diagnostics, compact 22.5 mm DIN-rail housing and compatibility with STB touch buttons or mechanical pushbuttons. When selecting a replacement, confirm supply voltage, input device type, output contact rating, feedback requirement, enclosure rating and safety category requirements. The AT-FM-10K is a two-hand control safety monitoring module, not a contactor, pushbutton, PLC, drive or motor starter; its role is to monitor two-hand actuation and safely enable redundant output contacts for machine safety control.
Get a Quote