Description
已思考
C-LIN HHS2: HHS2 Series Hour Meter and Timer Product Description
Brand and Product Identification
The C-LIN HHS2 is a series of digital hour meters and timers produced by C-Lin, also known as 欣灵电气,a Chinese manufacturer of relays, sensors, instruments and motor protection devices. The HHS2 model family functions as a timing component for industrial control circuits, test instruments and inspection benches. The HHS2 series includes related variants such as HHS2-1 (U), HHS2-2, HHS2-3 and HHS2-3R, each differing in display format, reset method, timing mode and terminal configuration. The basic HHS2 designation refers to the hour meter or timer platform rather than a single contactor, PLC module or power supply.
Product Function and Intended Use
The HHS2 hour meter accumulates operating time and displays elapsed timing for industrial equipment and control circuits. It is used in automation control circuits of industrial and mining enterprises, test instruments, inspection benches and machines where runtime hours must be recorded. The timer version can operate in contact timing or level-signal timing modes, starting or stopping timing according to the connected control contact or signal. The device is designed for timing and elapsed-time indication, not for motor starting, load switching or power distribution on its own.
Supply Voltage and Operating Conditions
The HHS2 control power supply voltage supports AC 380 V, AC 220 V, AC 110 V, AC 36 V or AC 24 V at 50 Hz, and DC 24 V, according to the selected model. Permissible supply fluctuation is 85 percent to 110 percent of the rated voltage. Ambient operating temperature ranges from minus 5 to plus 40 degrees Celsius. Installation altitude is up to 2000 m. Humidity at 40 degrees Celsius is up to 50 percent relative humidity; at lower temperatures, up to 90 percent humidity is allowed at 20 degrees Celsius, with special measures for occasional condensation. Pollution degree is grade 3.
Timing Range and Accuracy
The HHS2 timing range can cover seconds, minutes or hours according to the selected terminal configuration. Listed ranges include 1 s to 999 min 59 s, 0.1 min to 9999.9 min, 1 min to 999 h 59 min, and 0.1 h to 9999.9 h. Some HHS2-2 variants extend the minute and hour ranges to 99999.9 min and 99999.9 h. Timing error for standard HHS2 versions is listed as no more than 0.01 percent, while the HHS2-3 and HHS2-3R variants have a timing error of no more than 0.3 percent.
Display, Memory and Reset
The HHS2 uses a digital tube or Nixie tube display according to the variant. The device retains timing data for 10 years after power-off, using a built-in lithium battery or dedicated timing chip. Reset can be performed by a panel button switch or by terminal short-circuit signal. The HHS2-3 variant supports panel button reset, power-off reset or terminal short-circuit reset. The HHS2-3R variant adds automatic reset in addition to panel button reset, power-off reset and terminal short-circuit reset.
Contact and Signal Input Specifications
Related HHS2 timing contact specifications include maximum contact closure resistance of 10 kΩ or less during timing ON, and maximum open-contact resistance of 500 kΩ or more when timing OFF. Conventional heating current, Ith, is 5 A. Rated insulation voltage, Ui, is 400 V, and rated impulse withstand voltage, Uimp, is 2.5 kV. For level or current transformer timing, low level L is 0.2 V or less, and high level H ranges from 2 V to 30 V. Timing starts when the level signal changes from low to high and stops when it changes from high to low, with data retained. Signal rise or fall time should be less than 100 microseconds to avoid affecting timing accuracy.
Installation and Wiring
The HHS2 series supports rail-type or panel-type mounting, with specific mounting method varying by variant. Wiring follows the HHS2 terminal diagram in the datasheet. Timing control terminals are short-circuited to start timing, and range selection terminals are short-circuited to select seconds, minutes or hours. Reset terminals are connected for terminal short-circuit reset, and the panel button provides local reset. Because terminal functions differ between HHS2-1(U), HHS2-2, HHS2-3 and HHS2-3R, wiring and range selection should be checked against the exact model diagram before commissioning.
Typical Application Scenarios
Typical uses include runtime hour recording for motors, compressors, pumps, fans, welding equipment, packaging machines, test benches, inspection stations and industrial machinery. The timer can be applied to on-delay or elapsed-time functions in control circuits where equipment running time needs to be counted, displayed or retained after power loss. The HHS2 is suited to general industrial control environments rather than high-precision metering instruments or communication-connected energy management systems.
Advantages and Selection Notes
The HHS2 offers digital elapsed-time display, wide timing range, power-off data retention, button and terminal reset, multiple AC and DC supply options, panel or rail mounting, and compact timer-hour meter construction. When selecting a model, confirm the exact HHS2 variant, supply voltage, timing range, reset method, contact or signal input type, display format and mounting arrangement. The HHS2 is an hour meter or timer, not a relay output module, safety device, PLC, sensor or power supply; its role is to accumulate and display elapsed operating time in a control circuit.