Description
EATON ESR5-NO-31-24VAC-DC (V01): ESR5 Safety Relay Product Description
Brand and Product Identification
The EATON ESR5-NO-31-24VAC-DC, marked with version V01, is an electronic safety relay from the ESR5 safety relay family manufactured by Eaton Industries GmbH, Bonn, Germany. The model code ESR5-NO-31-24VAC-DC corresponds to catalog article number 118702 and EAN 4015081168422. The ESR5 relay is designed for use in machine safety circuits, specifically for emergency-stop and protective door monitoring, and is supplied as a DIN-rail mountable industrial control device. The V01 marking refers to the firmware or hardware revision level of the unit and should be noted alongside the model code when ordering replacement parts or requesting Eaton technical support.
Model Code Meaning and Contact Configuration
In the ESR5-NO-31-24VAC-DC designation, the ESR5 identifies the safety relay series, NO denotes the normally open contact configuration, 31 indicates the contact arrangement of three enabling paths plus one signaling path, and 24VAC-DC specifies a 24 V AC or DC supply voltage. The output side provides three undelayed enabling current paths at terminals 13/14, 23/24 and 33/34, together with one signaling current path at terminals 41/42. The enabling contacts carry the safety-related switching function, while the signaling contact provides a status feedback signal to a controller, indicator or remote monitoring system.
Power Supply and Electrical Input Data
The ESR5-NO-31-24VAC-DC operates from a 24 V AC or 24 V DC supply connected between terminals A1 and A2. Typical input current is approximately 140 mA at AC and 65 mA at DC. The input and start feedback circuit is rated for roughly 24 V DC at the input, and the maximum permissible overall conductor resistance in the input and reset circuit is about 50 ohms at nominal supply voltage. The relay uses M3 screw terminals for field wiring, with plug-in COMBICON-style terminal blocks accessible from the front of the housing.
Safety Ratings and Certification
The ESR5 relay is certified for safety-related applications under relevant functional safety standards. It achieves SIL 3 according to IEC 61508 for high-demand mode, with a PFHd value of 5.05 times 10 to the power of minus 10 per hour, a demand rate below 12 months, a proof test interval of 240 months and a duration of use of 240 months. The stop category according to IEC 60204 is category 0. The unit carries CE marking and UL listed, CSA certified and IEC rated approvals, and is designed for compliance with standards including IEC 61508, ISO 13849-1, IEC 62061, DIN EN 50178 and EN 60204-1.
Timing Behavior and Operating Sequence
The typical response time of the ESR5 relay is about 100 ms with automatic start, the typical release time is about 45 ms in single-channel operation, and the recovery time after a safety condition is approximately one second. After supply voltage is applied between A1 and A2, the Power LED illuminates. When the emergency-stop or safety-door monitoring inputs at S11/S12 and S21/S22 close, the ESR5 is ready for operation and the IN 1/2 LED lights. With the start condition satisfied, the enabling contacts 13/14, 23/24 and 33/34 close, while the signaling contact 41/42 follows the defined status logic. LED status indicators for channels K1 and K2 provide local visual feedback of relay state.
Mechanical Construction and Dimensions
The ESR5-NO-31-24VAC-DC housing is a compact DIN-rail mounted safety relay body with a metal lock for DIN rail mounting on the rear. The product depth is approximately 114.5 mm and the height is approximately 99 mm, with a narrow relay-style width suited to space-saving installation in machine control cabinets. Screw terminals support standard industrial control wiring cross sections, and the front layout separates power, input, feedback and output terminal groups for clear commissioning and maintenance.
Typical Application Scenarios
The ESR5 safety relay is used in machine and plant control circuits where emergency-stop buttons, protective doors, safety gates or similar protective devices require safety-related switching. Common installations include packaging machines, machine tools, conveyor systems, handling and robotics cells, assembly lines, and general production machinery where a safety relay must disconnect enabling contacts when a protective device is actuated. It can be wired for single-channel or dual-channel monitoring of safety inputs according to the required safety performance level of the machine.
Installation, Wiring and Maintenance Notes
Installation and commissioning must be carried out only by suitably qualified personnel following the Eaton operating instructions and local electrical regulations. Before installation, the supply must be disconnected, devices secured against accidental restart, isolation verified, and live neighboring equipment covered or enclosed. The functional earth must be connected to protective earth or potential equalization. Signal and sensor cables should be routed to avoid inductive or capacitive interference, and wiring should prevent undefined states caused by cable breakage. Routine maintenance consists of checking LED status, verifying contact operation, inspecting terminal tightness and cable condition, and confirming that safety inputs and feedback circuits operate according to the machine safety design. Faults in the relay or safety loop should be resolved before returning the machine to production.
Advantages and Positioning
The ESR5-NO-31-24VAC-DC offers three enabling contacts plus one signaling contact, a compact DIN-rail body, automatic or monitored start operation, standard 24 V AC/DC supply, and functional safety ratings up to SIL 3. It is positioned as a dedicated safety relay for basic to mid-level machine safety circuits. Users should confirm that the contact count, wiring method, supply voltage and safety category match the machine risk assessment and applicable standards before installation.
Get a Quote