Description
PEPPERL+FUCHS KFD2-RSH-1.2E.L3 Product Description
Overview
PEPPERL+FUCHS KFD2-RSH-1.2E.L3 is a 1-channel functional safety relay module of the Pepperl+Fuchs K-System isolation barrier family. PEPPERL+FUCHS KFD2-RSH-1.2E.L3 adopts ETS (energized-to-safe) logic, providing galvanic isolation between the safety control side and the 230V AC field load circuit. PEPPERL+FUCHS KFD2-RSH-1.2E.L3 is certified up to SIL 3 and widely used for safety interlock and valve actuation in process safety systems such as ESD and SIS.
Features
PEPPERL+FUCHS KFD2-RSH-1.2E.L3 supports line fault transparency (LFT) and continuous circuit diagnosis, detecting wire breakage or short-circuit faults on the field side. It has logic input range of 19–26.4V DC, matched with safety DO cards of DCS/ESD systems. The relay contact can switch loads up to 230V AC 5A, and it is suitable for AC solenoid valves and remote trip coils. PEPPERL+FUCHS KFD2-RSH-1.2E.L3 is 20 mm wide, DIN rail mount and compatible with K-System power rail. LED status indicators and collective fault output help on-site troubleshooting. It complies with IEC 61508 SIL3 and has DNV marine approval option. The ETS design means the load is safe when the relay is de-energized, which matches common safety interlock requirements.
Specs
Brand: PEPPERL+FUCHS Model: KFD2-RSH-1.2E.L3 Product series: K-System Product category: Safety relay module Safety level: SIL3 (SC3) Input: 19–26.4V DC logic input Field voltage: 50–230V AC / 60–110V DC Contact rating: 253V AC 5A (cosφ0.7) Width: 20 mm Mounting: DIN rail / K-System power rail Diagnosis: Line fault transparency LFT, collective fault output Function type: ETS energized-to-safe
Principle
PEPPERL+FUCHS KFD2-RSH-1.2E.L3 receives safety discrete commands from the ESD/DCS digital output card. When the safety signal is present, the internal safety relay is energized and the contact closes to activate the field actuator. When safety trip, wire fault or module internal failure occurs, the relay de-energizes and cuts off the load. PEPPERL+FUCHS KFD2-RSH-1.2E.L3 converts the safety controller low-voltage signal into isolated high-voltage switching output, and feeds fault diagnosis status back to the control system.
Applications
PEPPERL+FUCHS KFD2-RSH-1.2E.L3 is widely used in chemical, oil & gas, pharmaceutical and energy process SIS/ESD cabinets. It is commonly used for safety valve solenoid drive, emergency shutdown interlock, burner trip and safety isolation circuits. It is suitable for new safety cabinet construction and spare replacement of existing K-System safety barrier systems.
Get a Quote