Foxboro P0916VC 3m H/XLPE Double Shielded I/A Series DCS FBM Termination Connection Cable
Description
3. Product Specification Manual
3.1 Basic Product Information
Brand: Foxboro (Schneider Electric EcoStruxure Process Automation)
Model: P0916VC
Product Type: H/XLPE Double Shielded FBM Termination Cable
Applicable System: I/A Series Distributed Control System
Standard Fixed Length: 3m (9.8ft)
Conductor: 0.5mm² fine-stranded tinned oxygen-free copper wire
Inner Insulation: H/XLPE high-temperature cross-linked polyethylene
Outer Sheath: Hypalon anti-corrosion flame-retardant jacket (H-type H/XLPE series standard)
Connector: Dual-end factory pre-assembled gold-plated 37-pin D-Sub plug
Origin: United States
Net Weight: 0.24kg
Cable Outer Diameter: 8.8mm
Protection Grade: IP20 (for internal wiring of sealed industrial control cabinet)
3.2 Core Electrical Performance Parameters
Rated Operating Voltage: 300V AC/DC
Single Core Continuous Rated Current: 5A
Shield Structure: Independent pair foil shielding + overall copper braided shielding, shielding coverage ≥96%
Supported Signal Types: 4–20mA analog loop, HART digital communication, RTD/thermocouple weak signal, 24VDC switch input/output
EMC Compliance: IEC 61000-6-2 industrial anti-interference standard, suppress ground loop noise and inverter high-frequency radiation interference
Single Conductor Loop Resistance: ≤0.075Ω/m, ultra-low attenuation for high-precision process measurement
Plug Service Life: ≥10,000 times plugging/unplugging without contact failure
Insulation Resistance: ≥1000MΩ at 500VDC high voltage test
3.3 Environmental Operating Specifications
Long-term Continuous Working Temperature: -40℃ ~ +90℃
Short-term Peak Heat Resistance: 115℃ instantaneous tolerance
Storage & Transportation Temperature: -45℃ ~ +95℃
Working Humidity: 5%–95% RH, non-condensing
Environmental Grade: ISA S71.04 Class G3, resistant to oil mist, light corrosive gas, dust and mechanical vibration
Certifications: CE, RoHS, UL high-temperature cable certification
3.4 Core Functional Features
3m Long-distance Layout Design: Solve wiring demands between separated rack slots and split terminal bases in large-sized control cabinets
H/XLPE Hypalon High-temperature & Anti-corrosion Outer Jacket: Better heat resistance and chemical erosion resistance than ordinary PVC/LSZH cables, suitable for high-heat power, metallurgy and chemical cabinet environments
Factory Pre-terminated Dual Gold-plated Connectors: Eliminate manual wiring errors, greatly shorten DCS cabinet assembly and on-site maintenance cycle
Double-layer Full Shielding Architecture: Effectively isolate electromagnetic interference from high-power motors, frequency converters and high-voltage power cables, avoid analog signal drift and HART communication disconnection
Full Series Universal Compatibility: Perfectly matched with P0916UJ backplane, P0916UY signal isolation terminal base, all FBM200 analog/digital I/O modules; interchangeable with P0916VA, P0916VB short cables
Flexible Anti-fatigue Cable Body: Multi-strand soft copper core, withstand repeated bending during module replacement and cabinet wiring without internal wire breakage
3.5 Installation & Operation Precautions
P0916VC cable is only allowed to be laid inside fully sealed industrial control cabinets; outdoor exposure, direct heat source baking and liquid soaking are strictly prohibited
Separate signal cables and high-voltage power cables by ≥15cm during wiring; vertical 90° crossing must be adopted for unavoidable cross layout to reduce interference coupling
Cable shielding layer must implement single-point grounding on cabinet ground copper bar; double-end grounding will generate ground loop and cause measurement deviation of process signals
Minimum bending radius of the cable shall not be less than 6 times the outer diameter; avoid sharp bending, hard pulling and twisting during plugging and wiring
Do not arbitrarily cut, peel or damage cable insulation and shielding layer; unauthorized disassembly will void factory performance warranty
Check connector tightness every 3–6 months in high-vibration metallurgy and mining workshops; re-plug connectors if loose contact occurs
Classify and bind signal cables and power cables separately with soft cable ties; excessive compression that damages internal shielding is forbidden
4. Application Fields
Thermal Power & Waste Incineration Power Plant: Boiler, turbine auxiliary control cabinet long-span interconnection between FBM modules and signal terminals, adapt to high-temperature cabinet internal environment
Oil & Petrochemical Industry: Refinery, chemical synthesis workshop control cabinet analog signal and HART instrument wiring, anti-oil mist and weak corrosive gas erosion
Metallurgy & Mineral Processing: Smelting furnace, rolling mill high-temperature and high-vibration control cabinet long-distance module signal connection
Fine Chemical & Pharmaceutical Manufacturing: Reaction workshop, aseptic pharmaceutical DCS cabinet split rack wiring layout
Water Treatment & Desalination: Large-scale urban sewage plants, industrial circulating water multi-slot cabinet long-distance I/O signal transmission
Pulp & Paper Industry: Multi-unit large papermaking production line distributed control cabinet span wiring
Energy Storage & Substation Automation: Closed power distribution control room high-temperature cabinet internal instrument signal interconnection
Information Verification Note
Confirmed content: Product positioning as 3m H/XLPE double shielded FBM termination cable, Hypalon outer sheath material, 37-pin D-Sub dual-end connectors, 300V rated voltage, IP20 cabinet internal use, G3 environmental grade, full compatibility with P0916 series rack modules and FBM200 I/O, length coding rule from Foxboro official I/A cable specification PSS 31H
Content to be further verified: Maximum single cable supportable HART channel quantity, complete cable bending fatigue test data, factory customized length modification calibration procedures (only general cable technical parameters provided in original official manual, exclusive full test report of single P0916VC model not retrieved)