Foxboro P0916VA 0.5m H/XLPE Shielded Fieldbus Termination Cable for I/A Series DCS
June 12, 2026

Foxboro P0916VA 0.5m H/XLPE Shielded Fieldbus Termination Cable for I/A Series DCS

Foxboro P0916VA is an original factory-matched shielded signal cable dedicated to Foxboro I/A Series distributed control system, with a fixed length of 0.5 meters, H/XLPE high-temperature cross-linked insulation and overall shielding structure. It serves as the wired connection medium between FBM I/O modules, rack baseplates and DIN rail signal termination assemblies (TA), transmitting 4–20mA analog signals, HART digital superimposed signals and discrete switch signals simultaneously. The cable adopts multi-layer anti-interference shielding design, built-in high-purity oxygen-free copper conductors and flame-retardant outer sheath, supporting G3 harsh industrial environment long-term stable wiring layout. Fully compatible with P0916UJ backplane, P0916UY terminal base, all FBM200 series I/O modules and P0916 series cable serial models, it realizes quick plug-and-free wiring without on-site wire stripping and crimping, greatly shortening DCS cabinet assembly and maintenance cycle.

Description

3. Product Specification Manual

3.1 Basic Product Information

  • Brand: Foxboro (Schneider Electric EcoStruxure Process Automation)

  • Model: P0916VA

  • Product Type: Shielded I/O Termination Connection Cable

  • Applicable System: I/A Series Distributed Control System

  • Standard Length: 0.5m (1.6ft)

  • Insulation Material: H/XLPE Cross-linked Polyethylene High-temperature Insulation

  • Outer Sheath: Flame-retardant anti-corrosion PVC

  • Conductor Material: Tinned oxygen-free high-purity copper

  • Origin: United States

  • Matching Connector: Factory pre-crimped gold-plated plug terminals for FBM & TA bases

  • Net Weight: 0.14kg

  • Outer Diameter: 8.2mm

  • Protection Grade: IP20 (indoor cabinet wiring)

3.2 Electrical Performance Parameters

  1. Rated Operating Voltage: 300V AC/DC

  2. Maximum Continuous Current Per Core: 5A

  3. Conductor Cross-section: 0.5mm² fine-stranded copper wire

  4. Shield Structure: Overall copper braided shielding + independent core pair shielding, shielding coverage ≥95%

  5. Signal Transmission Support: 4–20mA analog loop, HART FSK digital signal, 24VDC discrete input/output

  6. EMC Performance: Suppress common-mode & differential electromagnetic interference, comply with IEC 61000-6-2 industrial anti-interference standard

  7. Loop Resistance: ≤0.08Ω/m per single conductor, low signal attenuation for precision measurement

3.3 Environmental Operating Specifications

  • Long-term Operating Temperature: -20℃ ~ +85℃

  • Short-term Peak Temperature: Up to 105℃ (H/XLPE high temperature resistance)

  • Storage & Transportation Temperature: -40℃ ~ +90℃

  • Working Humidity: 5% ~ 95% RH, non-condensing

  • Environmental Grade: ISA S71.04 Class G3, resistant to light chemical dust, oil mist and mild vibration

  • Certification Standards: CE, RoHS, UL flame retardant certification

3.4 Core Functional Features

  1. Pre-assembled Factory Terminals: Both ends pre-installed gold-plated plug connectors, no on-site crimping, plug-and-play for fast cabinet wiring

  2. High-temperature XLPE Insulation: Higher heat resistance than standard PVC cables, suitable for high-temperature power plant and metallurgy control cabinets

  3. Double-layer Full Shielding Design: Effectively isolate interference from frequency converters, high-power motors and power cables, avoid signal drift and HART communication loss

  4. Complete Series Compatibility: Matches all P0916 series baseplates, signal terminals and FBM analog/digital I/O modules; interchangeable with P0916DA PVC cable variant

  5. Flexible Anti-fatigue Structure: Multi-strand soft copper core, withstands repeated bending during cabinet wiring and module replacement without core breakage

  6. Flame-retardant & Anti-corrosion Outer Jacket: Resist cabinet internal oil mist, dust and weak corrosive gas, extend service life in chemical plants

3.5 Installation & Operation Precautions

  1. P0916VA cable is only allowed to be laid inside sealed industrial control cabinets; avoid outdoor exposure, direct heat source baking and liquid soaking

  2. Separate signal cables from high-voltage power cables by ≥15cm during wiring; cross layout must adopt vertical 90° crossing to reduce interference coupling

  3. The shielding layer of the cable must be single-point grounded at the cabinet ground bar; double-end grounding will generate ground loop noise and affect measurement accuracy

  4. Do not pull, twist or sharply bend the cable during plugging; minimum bending radius shall not be less than 6 times the cable outer diameter

  5. Do not cut or peel the cable insulation privately; damaged shielding and insulation will void factory signal stability warranty

  6. Regularly check connector looseness every 3–6 months in high-vibration metallurgy and mining workshops; re-plug if loose contact occurs

  7. Classify and bind signal cables and power cables separately with cable ties; avoid excessive compression damaging internal core shielding

4. Application Fields

Foxboro P0916VA 0.5m H/XLPE shielded termination cable is the standard short-distance wiring accessory for I/A Series DCS cabinet internal I/O signal interconnection, widely applied in all continuous process automation industries:
  1. Oil & Petrochemical: Refinery control cabinet internal FBM module and signal terminal short-distance signal connection, HART instrument signal transmission wiring

  2. Thermal Power & Waste Incineration Power Plant: Boiler, turbine auxiliary control cabinet high-temperature wiring, anti-interference analog signal cable layout

  3. Water Treatment & Desalination: Sewage, circulating water, seawater desalination DCS cabinet internal I/O module wiring

  4. Fine Chemical & Pharmaceutical: Aseptic workshop constant temperature & humidity control cabinet, reaction kettle parameter signal interconnection

  5. Metallurgy & Mineral Processing: Smelting furnace, rolling mill control cabinet high vibration environment short-distance signal wiring

  6. Pulp & Paper Industry: Papermaking production line DCS cabinet internal analog/digital signal connection

  7. Food & Beverage Manufacturing: Sterilization and batching workshop control cabinet instrument signal wiring

Information Verification Note

  1. Confirmed content: Product positioning as 0.5m H/XLPE shielded I/O termination cable for I/A Series, model length matching official P0916 cable coding rule, XLPE insulation double shielding, 300V rated voltage, cabinet internal wiring use, full compatibility with P0916 series rack modules and FBM I/O (source: Foxboro official I/A Series cable specification document PSS 31H)

  2. Content to be further verified: Exact maximum supported HART channel quantity per single cable, complete bending fatigue test parameter data, factory customized cable assembly calibration steps (only general cable technical parameters provided by official manual, no exclusive single P0916VA full test report retrieved)


Get a Quote