Foxboro P0916VA 0.5m H/XLPE Shielded Fieldbus Termination Cable for I/A Series DCS
Description
3. Product Specification Manual
3.1 Basic Product Information
Brand: Foxboro (Schneider Electric EcoStruxure Process Automation)
Model: P0916VA
Product Type: Shielded I/O Termination Connection Cable
Applicable System: I/A Series Distributed Control System
Standard Length: 0.5m (1.6ft)
Insulation Material: H/XLPE Cross-linked Polyethylene High-temperature Insulation
Outer Sheath: Flame-retardant anti-corrosion PVC
Conductor Material: Tinned oxygen-free high-purity copper
Origin: United States
Matching Connector: Factory pre-crimped gold-plated plug terminals for FBM & TA bases
Net Weight: 0.14kg
Outer Diameter: 8.2mm
Protection Grade: IP20 (indoor cabinet wiring)
3.2 Electrical Performance Parameters
Rated Operating Voltage: 300V AC/DC
Maximum Continuous Current Per Core: 5A
Conductor Cross-section: 0.5mm² fine-stranded copper wire
Shield Structure: Overall copper braided shielding + independent core pair shielding, shielding coverage ≥95%
Signal Transmission Support: 4–20mA analog loop, HART FSK digital signal, 24VDC discrete input/output
EMC Performance: Suppress common-mode & differential electromagnetic interference, comply with IEC 61000-6-2 industrial anti-interference standard
Loop Resistance: ≤0.08Ω/m per single conductor, low signal attenuation for precision measurement
3.3 Environmental Operating Specifications
Long-term Operating Temperature: -20℃ ~ +85℃
Short-term Peak Temperature: Up to 105℃ (H/XLPE high temperature resistance)
Storage & Transportation Temperature: -40℃ ~ +90℃
Working Humidity: 5% ~ 95% RH, non-condensing
Environmental Grade: ISA S71.04 Class G3, resistant to light chemical dust, oil mist and mild vibration
Certification Standards: CE, RoHS, UL flame retardant certification
3.4 Core Functional Features
Pre-assembled Factory Terminals: Both ends pre-installed gold-plated plug connectors, no on-site crimping, plug-and-play for fast cabinet wiring
High-temperature XLPE Insulation: Higher heat resistance than standard PVC cables, suitable for high-temperature power plant and metallurgy control cabinets
Double-layer Full Shielding Design: Effectively isolate interference from frequency converters, high-power motors and power cables, avoid signal drift and HART communication loss
Complete Series Compatibility: Matches all P0916 series baseplates, signal terminals and FBM analog/digital I/O modules; interchangeable with P0916DA PVC cable variant
Flexible Anti-fatigue Structure: Multi-strand soft copper core, withstands repeated bending during cabinet wiring and module replacement without core breakage
Flame-retardant & Anti-corrosion Outer Jacket: Resist cabinet internal oil mist, dust and weak corrosive gas, extend service life in chemical plants
3.5 Installation & Operation Precautions
P0916VA cable is only allowed to be laid inside sealed industrial control cabinets; avoid outdoor exposure, direct heat source baking and liquid soaking
Separate signal cables from high-voltage power cables by ≥15cm during wiring; cross layout must adopt vertical 90° crossing to reduce interference coupling
The shielding layer of the cable must be single-point grounded at the cabinet ground bar; double-end grounding will generate ground loop noise and affect measurement accuracy
Do not pull, twist or sharply bend the cable during plugging; minimum bending radius shall not be less than 6 times the cable outer diameter
Do not cut or peel the cable insulation privately; damaged shielding and insulation will void factory signal stability warranty
Regularly check connector looseness every 3–6 months in high-vibration metallurgy and mining workshops; re-plug if loose contact occurs
Classify and bind signal cables and power cables separately with cable ties; avoid excessive compression damaging internal core shielding
4. Application Fields
Oil & Petrochemical: Refinery control cabinet internal FBM module and signal terminal short-distance signal connection, HART instrument signal transmission wiring
Thermal Power & Waste Incineration Power Plant: Boiler, turbine auxiliary control cabinet high-temperature wiring, anti-interference analog signal cable layout
Water Treatment & Desalination: Sewage, circulating water, seawater desalination DCS cabinet internal I/O module wiring
Fine Chemical & Pharmaceutical: Aseptic workshop constant temperature & humidity control cabinet, reaction kettle parameter signal interconnection
Metallurgy & Mineral Processing: Smelting furnace, rolling mill control cabinet high vibration environment short-distance signal wiring
Pulp & Paper Industry: Papermaking production line DCS cabinet internal analog/digital signal connection
Food & Beverage Manufacturing: Sterilization and batching workshop control cabinet instrument signal wiring
Information Verification Note
Confirmed content: Product positioning as 0.5m H/XLPE shielded I/O termination cable for I/A Series, model length matching official P0916 cable coding rule, XLPE insulation double shielding, 300V rated voltage, cabinet internal wiring use, full compatibility with P0916 series rack modules and FBM I/O (source: Foxboro official I/A Series cable specification document PSS 31H)
Content to be further verified: Exact maximum supported HART channel quantity per single cable, complete bending fatigue test parameter data, factory customized cable assembly calibration steps (only general cable technical parameters provided by official manual, no exclusive single P0916VA full test report retrieved)
Get a Quote