Foxboro P0916VB 1m LSZH Double Shielded I/A Series DCS FBM Termination Connection Cable
Description
3. Product Specification Manual
3.1 Basic Product Information
Brand: Foxboro (Schneider Electric EcoStruxure Process Automation)
Model: P0916VB
Product Type: LSZH Double Shielded FBM Termination Cable
Applicable System: I/A Series Distributed Control System
Standard Fixed Length: 1m (3.28ft)
Conductor: 0.5mm² fine-stranded tinned oxygen-free copper wire
Insulation Material: H/XLPE high temperature cross-linked polyethylene
Outer Sheath: LSZH Low Smoke Zero Halogen flame retardant sheath
Connector: Dual-end pre-crimped gold-plated 37-pin D-Sub plug
Origin: United States
Net Weight: 0.18kg
Cable Outer Diameter: 8.5mm
Protection Grade: IP20 (indoor cabinet wiring)
3.2 Core Electrical Performance Parameters
Rated Voltage: 300V AC/DC
Single Core Continuous Rated Current: 5A
Shield Structure: Pair independent shielding + overall copper braided shielding, coverage ≥96%
Supported Signal Types: 4–20mA analog loop, HART FSK digital signal, 24VDC DI/DO discrete signals, RTD/TC weak measurement signals
EMC Standard: IEC 61000-6-2 industrial anti-interference, suppress common-mode ground loop noise and frequency converter electromagnetic radiation
Single Conductor Loop Resistance: ≤0.075Ω/m, ultra-low signal attenuation for high-precision process measurement
Contact Service Life of Plug: ≥10,000 times plugging/unplugging without poor contact
3.3 Environmental Operating Specifications
Long-term Working Temperature: -25℃ ~ +85℃
Instant Peak Heat Resistance: 110℃ short-time tolerance
Storage & Transportation Temperature: -40℃ ~ +90℃
Working Humidity: 5%–95% RH, non-condensing
Environmental Grade: ISA S71.04 Class G3, resistant to oil mist, light corrosive dust and mechanical vibration
Certifications: CE, RoHS, UL LSZH fire safety certification
3.4 Core Functional Features
LSZH Low Smoke Zero Halogen Design: No toxic halogen gas release during fire, low smoke density, compliant with power plant, chemical plant fire safety cabinet wiring standards
Factory Pre-terminated Dual Gold-plated Connectors: Eliminate on-site wiring errors, greatly shorten DCS cabinet assembly and maintenance cycle
Double-layer Full Shielding Structure: Effectively isolate interference from high-power motors, inverters and high-voltage power cables, avoid analog signal drift and HART communication interruption
Full Series Universal Compatibility: Matches P0916UJ backplane, P0916UY signal terminal base, all FBM200 analog/digital I/O modules; interchangeable with P0916VA 0.5m short cable
Anti-fatigue Flexible Cable Body: Multi-strand soft copper core, withstand repeated bending during module replacement and cabinet wiring without internal wire breakage
High Temperature & Anti-corrosion Performance: H/XLPE insulation resists cabinet internal heat accumulation, LSZH sheath is resistant to weak acid and oil mist erosion in chemical workshops
3.5 Installation & Operation Precautions
P0916VB cable shall only be laid inside fully sealed industrial control cabinets; outdoor exposure, direct heat source baking and liquid soaking are prohibited
Separate signal cables and high-voltage power cables by at least 15cm during wiring; vertical 90° crossing must be adopted for unavoidable cross layout to reduce interference coupling
Cable shielding layer must implement single-point grounding on cabinet ground copper bar; double-end grounding will generate ground loop and cause signal measurement deviation
Minimum bending radius of the cable shall not be less than 6 times the outer diameter; avoid sharp bending, pulling and twisting during plugging and wiring
Do not arbitrarily cut, peel or damage cable insulation and shielding layer; unauthorized disassembly will void factory stability warranty
Check connector tightness every 3–6 months in high-vibration metallurgy and mining workshops; re-plug connectors if loose contact occurs
Classify and bind signal cables and power cables separately with soft cable ties; excessive compression that damages internal shielding is forbidden
4. Application Fields
Thermal Power & Waste Incineration Power Plant: Boiler, turbine auxiliary control cabinet internal FBM module and signal terminal interconnection, LSZH cable mandatory fire safety wiring
Oil & Petrochemical Industry: Refinery, chemical synthesis workshop control cabinet analog signal and HART instrument wiring, anti-corrosion and flame retardant demand scenarios
Fine Chemical & Pharmaceutical Manufacturing: Aseptic pharmaceutical workshop, pesticide production line DCS cabinet internal I/O signal transmission
Water Treatment & Desalination: Large urban sewage plants, industrial circulating water control cabinet medium-distance wiring layout
Metallurgy & Mineral Processing: Smelting furnace, rolling mill high-vibration control cabinet internal module signal connection
Pulp & Paper Industry: Multi-unit papermaking production line DCS cabinet distributed signal wiring
Underground Tunnel & Substation Automation: Low-smoke zero-halogen safety wiring for closed underground control rooms
Information Verification Note
Confirmed content: Product positioning as 1m LSZH double shielded FBM termination cable, dual-end 37-pin D-Sub gold-plated connectors, 300V rated voltage, IP20 cabinet internal use, G3 environmental grade, full compatibility with P0916 series rack modules and FBM200 I/O, LSZH fire protection core feature (source: Foxboro I/A Series official cable specification PSS 41H and automation supplier public product data of P0916VB)
Content to be further verified: Maximum single cable supportable HART channel quantity, complete cable bending fatigue test data, factory customized length modification calibration procedures (only general cable technical parameters provided in original official manual, exclusive full test report of single P0916VB model not retrieved)
Get a Quote