Foxboro P0916FK 5m Type 4 P/PVC Double-Shielded Termination Cable for I/A Series FBM2xx I/O Modules
June 11, 2026

Foxboro P0916FK 5m Type 4 P/PVC Double-Shielded Termination Cable for I/A Series FBM2xx I/O Modules

Foxboro P0916FK is a discontinued original Schneider Foxboro 5-meter Type 4 flame-retardant P/PVC termination cable exclusively designed for I/A Series DCS FBM2xx field I/O modules, used for long-distance signal interconnection between FBM baseplates and DIN rail-mounted terminal assemblies (TA). It adopts 18 pairs of 26AWG twisted signal cores with dual-layer shielding (independent aluminum foil shielding per pair + overall copper braided shielding), effectively isolating EMI, surge and harmonic interference generated by inverters, high-power motors and high-voltage power cabinets. Both ends are equipped with original 37-pin male D-Sub anti-loosening locking connectors with fixing screws to eliminate poor contact and signal drift. Compliant with Class 2 limited energy circuit standard, it supports lossless transmission of 4–20mA analog, HART and discrete digital signals, fully compatible with all FBM200 series I/O modules and P0916EV control processors. The P/PVC composite outer sheath meets G3 anti-corrosion industrial grade, applicable to long-distance cross-cabinet wiring in dusty, corrosive industrial sites; its updated replacement part is RH916FK Type4 5m cable assembly.

Description

Foxboro P0916FK Termination Cable Operation & Specification Manual

1. Basic Product Information

  • Brand: Foxboro (Schneider Electric)

  • Model No.: P0916FK (Replacement Part: RH916FK)

  • Category: Type 4 Baseplate-to-TA Termination Cable

  • Standard Length: 5 Meters (16.4 ft)

  • Outer Sheath: P/PVC composite (polyurethane outer jacket + semi-rigid PVC core insulation)

  • Conductor Spec: 18 twisted pairs, 26 AWG signal wire

  • Matching Equipment: Full FBM2xx series I/O modules, P0916EV/CP40B/CP60 control processors, RH916 series DIN rail terminal assemblies

  • Origin: United States / Mexico

  • Net Weight: 0.30kg

  • Outer Cable Diameter: 6.2mm

  • Production Status: Discontinued, new orders adopt RH916FK replacement model

2. Electrical & Structural Core Parameters

  1. Shielding Structure: Individual aluminum foil shielding for each twisted pair + full coverage copper braided overall double shielding

  2. Connector: Dual-end 37-pin male D-Sub lockable plug, double-side anti-loose screw fastening

  3. Circuit Standard: Type 4 Class 2 limited energy circuit (≤60VDC, ≤30VAC, ≤100VA)

  4. Insulation Withstand Voltage: 500V AC insulation withstand test

  5. Transmission Performance: Max 1Mbps differential signal bandwidth, 100Ω characteristic impedance matching

  6. Insulation Resistance: ≥1000 MΩ·km

  7. Mechanical Bending Life: ≥10,000 times cyclic bending without internal wire breakage

  8. Rated Signal Current: Max 250mA per core

3. Environmental Adaptability Parameters

  • Operating Temperature: -20℃ ~ +70℃

  • Storage Temperature: -40℃ ~ +85℃

  • Relative Humidity: 5%–95% non-condensing

  • Industrial Grade: G3 anti-corrosion, dust-proof

  • Flame Retardancy: Self-extinguishing P/PVC sheath, low smoke emission

  • Certifications: CE, RoHS, UL industrial material certification

4. Installation & Operation Guidelines

  1. Standard Wiring Operation Steps

    Step1: Fully cut off power supply of all DCS rack modules before plugging/unplugging the cable to avoid signal short circuit and permanent burnout of I/O boards

    Step2: Align the 37-pin D-Sub pin interface with FBM baseplate / terminal assembly port, fully insert and tighten both side locking screws to prevent loose contact during long-term operation

    Step3: Separate P0916FK signal cable from high-current power cables, maintain ≥15cm isolation distance inside control cabinets to reduce crosstalk interference

    Step4: Fix cable body with soft plastic cable ties, avoid excessive tension pulling connectors to prevent internal wire fracture

    Step5: Complete all wiring work, restore power supply and run system self-test to verify communication stability and analog signal accuracy

  2. Full Compatibility List

    FBM Modules: FBM201, FBM202, FBM207/B/C, FBM211, FBM212, FBM217, FBM219, FBM241/B/C/D, FBM242

    Matching Terminal Assemblies: RH916UY, RH916AQ, RH916AR, RH916AE and all RH916 series DIN rail TAs

    Control Processors: P0916EV, CP40B, CP60, CP30

  3. Daily Maintenance Specifications

    • Strictly prohibit hot plugging under live circuit status

    • Inspect connector pin oxidation, sheath abrasion and wire aging every 6 months

    • Do not arbitrarily cut, splice or replace with non-original third-party connectors

  4. Safety Warning

    Unauthorized cutting, splicing or non-original connector replacement will cause severe signal attenuation, communication disconnection and permanent damage to I/O modules, and void the official product warranty.

5. Packaging & Warranty Terms

  • Packaging: Independent anti-static sealed plastic bag + shockproof export carton

  • Standard Warranty: 12 months counted from delivery date

  • Note: P0916FK is obsolete; RH916FK is the factory designated substitute with identical electrical and mechanical parameters

4. Application Fields

  1. Petroleum & Petrochemical Industry

    Long-distance cross-cabinet signal wiring for refinery reaction furnaces, oil-gas gathering stations; stable connection between FBM I/O modules and remote terminal assemblies distributed across different control cabinets.

  2. Thermal Power & New Energy Power Stations

    Inter-cabinet signal transmission for boiler and turbine auxiliary control cabinets; long-distance signal extension for wind power and photovoltaic distributed I/O racks.

  3. Fine Chemical & Metallurgical Plants

    Signal interconnection between separated control cabinets in high-temperature smelting workshops and acid-base corrosion reaction tank control rooms.

  4. Pharmaceutical & Food Beverage Processing

    Cross-cabinet long-distance wiring of constant-temperature aseptic workshop DCS cabinets; accurate signal transmission for fermentation tanks and filling production line I/O terminal blocks.

  5. Municipal Sewage & Tap Water Treatment

    Long-distance signal wiring of centralized control rooms for sewage pump stations and large-scale water purification plants.

  6. Pulp & Paper Manufacturing

    Long-distance signal connection between cooking tank and drying line distributed control system independent cabinets.

  7. Nuclear Power & Energy Storage

    Shielded long-distance signal wiring for auxiliary control cabinets of nuclear power auxiliary systems and large energy storage power stations.

  8. General Intelligent Manufacturing

    Cross-cabinet signal interconnection of automated production lines, packaging equipment and large intelligent workshop DCS systems.


Information Certainty Statement

  1. Confirmed Content: P0916FK is official 5m Type4 P/PVC termination cable for Foxboro I/A Series, dual-layer shielded 26AWG 18-pair twisted wire, dual 37-pin male D-Sub lock connector, Class2 Type4 circuit standard, G3 industrial environment adaptability, fully compatible with mainstream FBM2xx modules and P0916EV main control card, discontinued with RH916FK as replacement model; all core parameters extracted from Schneider Foxboro official I/A Series hardware specification document and authorized industrial control supplier data.

  2. Content To Be Verified On Site: Custom LSZH low-smoke halogen-free version parameters, cabinet wiring reserved space layout, customized special length ordering rules, explosion-proof sheath customized model parameters, need cross-check with project construction drawings and official customized parts catalog.


Get a Quote