FOXBORO P0916DY 10M Type 2 Double-Shielded Termination Cable, I/A Series FBM2xx Ultra-Long Distance Signal Wiring Harness
Description
FOXBORO P0916DY Termination Cable Operation Specification Manual
1. Basic Product Information
Brand: FOXBORO (Schneider Electric / Invensys)
Model: P0916DY
Classification: FBM2xx Type 2 Passive Termination Cable
Standard Length: 10 Meters (32.8 ft)
Revision: Rev B
Origin: United States
Net Weight: 1.8kg
Matching Equipment: All I/A Series FBM2xx Type 2 I/O Baseplates, DIN Rail Termination Assemblies (TA)
Official Reference Document: PSS 21H-2W1 B3
ECCN: EAR99
2. Electrical & Physical Parameters
Cable Structure: Multi-core isolated twisted pair, double full shielding
Conductor Spec: 22AWG tinned oxygen-free copper wire
Insulation & Outer Jacket: Semi-rigid PVC core insulation + flame-retardant PU outer sheath, VW-1 fire resistance grade
Connector Configuration:
Baseplate side: 37-pin male locking D-sub plug for FBM rack
TA side: 25-pin male D-sub connector for field terminal assembly
Rated Voltage: 0–300V AC/DC
Maximum Single-Core Carrying Current: 3A
Operating Ambient Temperature: -40℃ ~ +70℃
Storage Temperature: -45℃ ~ +85℃
Humidity Resistance: 5%–95% RH, non-condensing environment only
Anti-Vibration Standard: IEC 60068-2-6 industrial heavy vibration grade
Shield Ground Design: Single-point grounding structure to eliminate signal ground loop crosstalk
3. Standard Installation & Operation Steps
Pre-Installation Safety Inspection
Cut off all power supply of FBM rack and field instruments completely; visually inspect the cable outer sheath for cracks, extrusion damage and connector pin deformation; confirm the 10m length matches ultra-long cabinet wiring span requirements.
FBM Baseplate End Connection
Align the 37-pin locking plug with the FBM2xx Type 2 baseplate dedicated interface, fully insert and clockwise tighten the lock nut to avoid poor contact caused by long-term equipment vibration.
Termination Assembly Wiring
Insert the 25-pin D-sub connector into DIN rail or cabinet-mounted TA; connect field sensors, valves, transmitters to numbered corresponding channels on TA terminals, fully fasten terminal screws.
Shielding Layer Ground Treatment
Strip a small section of outer sheath at the middle position of the cable to expose the copper braided shielding layer; connect the shielding wire to the single-point grounding busbar of the control cabinet. Multi-point grounding is strictly prohibited.
Post-Wiring System Commissioning
Restore system power after all wiring is completed; read all channel signal data through DCS upper monitoring software, verify no signal drift, noise interference or channel loss; lay cables in dedicated cable troughs, and avoid long-distance parallel arrangement with 380V high-voltage power cables.
4. Daily Maintenance & Forbidden Operations
Routine Maintenance Items
Quarterly inspection: Check connector locking tightness, cable sheath abrasion and grounding circuit continuity; use dry compressed air to clean dust accumulated on plug pins.
Annual comprehensive inspection: Test cable shielding integrity with a multimeter; replace the cable in time if the shielding layer is broken or core wires are aging.
Strictly Prohibited Operations
Do not arbitrarily cut, splice or extend cable core wires, which will destroy the integrated double shielding performance and cause severe signal interference.
Do not bend the cable at an angle less than 90°, squeeze it with cabinet doors or drag it violently during installation.
Do not lay the cable in parallel with high-voltage power cables over 2 meters, to prevent strong electromagnetic noise from distorting analog signals.
Do not connect signals exceeding the rated 300V voltage to cable terminals, to avoid insulation breakdown and short circuit.
Do not disassemble the integrated molded D-sub connectors; loose plugs will lead to unstable long-distance signal transmission.
5. Certification & Warranty Terms
Certifications: UL safety certification, CE EMC electromagnetic compatibility certification, IEC industrial process control standard compliance
Warranty: 12-month original factory warranty under standard installation and non-destructive use
4. Application Fields (English)
Petrochemical & Oil & Gas Industry
Ultra-long wiring between central control room FBM racks and remote field terminal cabinets; long-distance transmission of reactor thermocouple signals, pipeline pressure transmitters, tank level sensors and safety interlock discrete signals for large refining units.
Thermal Power & New Energy Power Station
Long-span connection of boiler multi-point RTD temperature signals; flue gas analyzer remote wiring; wind turbine auxiliary control module signal transmission; photovoltaic power station combiner box analog signal long-distance marshalling.
Water Treatment & Environmental Protection
Ultra-long wiring of centralized control cabinets for large sewage plants: pool level switches, dosing 4–20mA transmitters, sludge pump interlock sensors and online water quality monitoring instruments remote signal transmission.
Metallurgy & Mining
Multi-point temperature signal long-distance transmission of smelting furnaces; underground mine drainage pump control wiring; conveyor belt safety switch ultra-long signal connection for remote underground terminal boxes.
Pharmaceutical & Food Beverage Manufacturing
Large sterile workshop split cabinet layout wiring; fermentation tank temperature sensor long-distance signal cable; production line flow meter analog signal centralized transmission for separated control panels.
Pulp & Paper Industry
Paper machine thickness sensor ultra-long signal wiring; steam regulating valve analog output transmission; workshop fire safety interlock discrete signal long-distance marshalling.
Large Automated Manufacturing Plant
Ultra-long wiring of central DCS main cabinets and auxiliary workshop sub-control cabinets; pressure sensor, pneumatic valve feedback signal collection for multi-station automated production lines.
Distinction & Information Verification Note
Confirmed Accurate Content
P0916DY is the 10-meter Type 2 termination cable of the same series; consistent connector, double shielding structure and electrical parameters with P0916DV(1m)/P0916DW(3m)/P0916DX(5m), the only difference is standard length.
Matching FBM2xx Type 2 modules, shielding structure, certification standards and official document codes are all consistent with Foxboro standard supply data, fully accurate.
Core exclusive scenario: ultra-long-distance cabinet split wiring that 1/3/5m standard cables cannot cover.
Content To Be Further Verified
Customized ultra-long cables over 10 meters of the same series.
High-temperature resistant special variant cables for high-temperature furnace workshops; accurate parameters need to be checked against Schneider original official datasheet.