Foxboro P0916BX Compression Termination Assembly for FBM214/FBM216 HART Analog Input Module, I/A Series DCS Field Wiring Terminal Block
June 11, 2026

Foxboro P0916BX Compression Termination Assembly for FBM214/FBM216 HART Analog Input Module, I/A Series DCS Field Wiring Terminal Block

The Foxboro P0916BX is a dedicated compression-type passive termination assembly exclusively matched with Foxboro FBM214 and FBM216 HART analog input modules under Schneider Electric I/A Series distributed control system. It serves as the core wiring bridge between field HART smart transmitters and rack-mounted FBM I/O cards, supporting 8 channels of 4–20mA analog signals with built-in HART FSK signal pass-through function, realizing simultaneous analog measurement and digital HART protocol data reading without additional signal separators. This termination unit adopts compression spring terminal design, compatible with 0.2–4mm² solid/stranded cables, enabling fast wiring and convenient on-site maintenance. Each channel is equipped with independent LED status indicators to visually display normal operation, open circuit, short circuit and over-range faults. It adopts group galvanic isolation of 1500V AC to suppress industrial on-site common-mode electromagnetic interference, ensuring stable transmission of weak HART digital signals.

Description

3. Product Specification & Operation Manual

Foxboro P0916BX Operation Manual

3.1 Core Electrical Parameters

  1. Power Supply: Passive wiring terminal, loop power supplied by external 24VDC power supply or FBM auxiliary power

  2. Signal Channel: 8 independent channels, support 4–20mA analog + HART FSK superimposed signal

  3. Maximum Loop Resistance: 900Ω, compatible with all mainstream HART pressure, temperature, flow and liquid level transmitters

  4. Isolation Performance: 1500V AC group isolation; CMRR>110dB for 50/60Hz power frequency interference suppression

  5. Protection Circuit: Built-in channel overcurrent, surge and short-circuit protection to prevent transmitter and FBM card burnout

  6. Communication Matching: Dedicated P0916 series termination cable for seamless connection with FBM214/FBM216 baseplate, support redundant fieldbus transmission

3.2 Environmental Specifications

  • Operating Temperature: -40℃ ~ +70℃

  • Storage Temperature: -50℃ ~ +85℃

  • Ambient Humidity: 5%–95% RH, non-condensing

  • Protection Class: IP20 (indoor control cabinet installation only)

  • Vibration & Shock Standard: IEC 60068-2-6, IEC 60068-2-7

  • Applicable Environment: Class G3 dust, mild corrosive gas industrial sites

  • Certifications: CE, UL61010, RoHS, ATEX Zone 2

3.3 Mechanical & Wiring Parameters

  • Overall Dimension: 125mm(H) × 212mm(W) × 168mm(D)

  • Net Weight: 0.43kg

  • Mounting Method: Standard 35mm DIN rail snap-in installation

  • Terminal Type: Detachable compression spring terminals, wire range 0.2–4mm², ferrules available for fine wires

  • Status LED Definition: Green = Normal signal; Red = Open/short fault; Orange = Signal over-range

  • Matching I/O Card: FBM214, FBM216 HART analog input modules

3.4 Core Functional Features

  1. Professional HART signal through-type termination, collect both 4–20mA analog value and HART digital parameters (device tag, calibration data, fault alarm)

  2. Compression spring terminals without screws, quick wiring and easy cable replacement during overhaul

  3. Channel-by-channel LED fault indication, rapid field troubleshooting without testing instruments

  4. Passive signal transmission, zero attenuation of analog and HART digital signals, no loss of measurement accuracy

  5. Compatible with redundant DCS rack architecture, support seamless switchover of dual FBM control loops

  6. Plug-and-play with full P0916 series dedicated cables, no secondary signal calibration after installation

3.5 Standard Installation Steps

  1. Cut off the DCS rack 24VDC power supply before installing or removing P0916BX termination assembly;

  2. Snap the unit onto DIN rail inside the cabinet and lock the bottom fixing buckle tightly;

  3. Connect two-wire HART transmitter cables to corresponding channel compression terminals strictly following wiring diagram;

  4. Connect the dedicated 37-pin termination cable between P0916BX and FBM214/FBM216 rear baseplate connector;

  5. Restore rack power, log in I/A workstation software to enable HART communication and configure alarm thresholds;

  6. Check LED status of each channel one by one, verify normal analog collection and HART digital data upload.

3.6 Safety Warning Clauses

  1. Only certified industrial automation engineers are allowed to disassemble or modify the product; unauthorized disassembly voids the warranty.

  2. Always cut off 24VDC power before wiring, plugging or unplugging the termination assembly to avoid circuit short-circuit burnout.

  3. Do not install the unit in flammable, explosive or strong corrosive gas environments without sealed explosion-proof cabinets.

  4. Reserve heat dissipation gaps around the module to prevent overheating leading to HART communication failure and signal drift.

  5. Tighten compression terminals quarterly to avoid poor contact causing signal loss or HART communication interruption.

4. Application Fields

  1. Oil & Gas Industry: Oil well HART pressure/temperature transmitter wiring, long-distance pipeline flow monitoring, refinery reactor HART multi-parameter signal collection

  2. Thermal & Hydropower Generation: Boiler furnace HART temperature sensor terminal processing, steam pressure and circulating water flow smart transmitter signal transmission

  3. Petrochemical & Fine Chemical Industry: Reaction kettle liquid level, pH, catalyst temperature HART signal centralized wiring, raw material storage tank intelligent instrument data acquisition

  4. Water Treatment Industry: Sewage plant dissolved oxygen, turbidity, dosing pump HART transmitter connection, municipal water supply pipeline pressure monitoring

  5. Metallurgical Smelting Industry: Blast furnace temperature, molten metal liquid level, cooling water flow HART instrument signal termination

  6. Pharmaceutical & Food Manufacturing: Clean workshop constant temperature & humidity smart sensor wiring, production tank level HART parameter collection

  7. Pulp & Paper Industry: Paper machine tension, pulp flow, drying oven temperature HART analog signal transmission

  8. Energy Storage & Building Energy Management: Central air conditioning chiller, heating pipeline HART temperature-pressure transmitter signal processing


Get a Quote