IPM02
May 13, 2026

IPM02

1. Core Technical Specifications - Model: IDP10-AF1C01F - Model: IPM02 - Brand: Foxboro (Schneider Electric) - Product Type: Differential Pressure Transmitter (for industrial process pressure measurement) - Product Type: Industrial Automation Control Module (for Foxboro I/A Series DCS systems) - Input Voltage: 24VDC~75VDC - Input Voltage: 12-48VDC (dual redundant power supply input) - Output Parameters: 4-20mA standard signal; measuring range: 0.125kPa to 21MPa - Output Parameters: 4-20mA analog output; 2 input channels, 4 output channels; supports RS-485 Modbus communication[1] - Protection Functions: Overvoltage, overcurrent, overheating, short-circuit protection - Operating Temperature: -20℃ to +60℃ - Operating Temperature: -20℃ to +70℃ - Mounting: Process direct connection or bracket installation (optional) - Mounting: 35mm DIN rail installation (complying with IEC 60715)[2] - Protection Grade: IP66 (suitable for on-site process installation) - Protection Grade: IP30 (wave纹 aluminum housing, enhanced anti-interference)[2]

Description

1. Core Technical Specifications

  • Model: IDP10-AF1C01F

  • Model: IPM02

  • Brand: Foxboro (Schneider Electric)

  • Product Type: Differential Pressure Transmitter (for industrial process pressure measurement)

  • Product Type: Industrial Automation Control Module (for Foxboro I/A Series DCS systems)

  • Input Voltage: 24VDC~75VDC

  • Input Voltage: 12-48VDC (dual redundant power supply input)

  • Output Parameters: 4-20mA standard signal; measuring range: 0.125kPa to 21MPa

  • Output Parameters: 4-20mA analog output; 2 input channels, 4 output channels; supports RS-485 Modbus communication[1]

  • Protection Functions: Overvoltage, overcurrent, overheating, short-circuit protection

  • Operating Temperature: -20℃ to +60℃

  • Operating Temperature: -20℃ to +70℃

  • Mounting: Process direct connection or bracket installation (optional)

  • Mounting: 35mm DIN rail installation (complying with IEC 60715)[2]

  • Protection Grade: IP66 (suitable for on-site process installation)

  • Protection Grade: IP30 (wave纹 aluminum housing, enhanced anti-interference)[2]

2. Brief Product Overview

IDP10-AF1C01F is an industrial-grade differential pressure transmitter under Foxboro brand, designed for industrial process pressure measurement (applicable to liquid, gas or steam media). It adopts proven polysilicon technology, featuring compact structure, high measurement accuracy, and strong environmental adaptability, suitable for harsh industrial environments such as petrochemical, power generation, and metallurgy. The transmitter realizes stable differential pressure measurement and signal conversion, supports configuration and status monitoring, and is easy to install and maintain, ensuring accurate and continuous measurement of on-site process parameters[3].IPM02 is an industrial-grade automation control module under Foxboro brand (Schneider Electric), designed for Foxboro I/A Series DCS systems. It integrates high-performance data processing and signal conversion functions, adopting dual redundant power supply design and RS-485 Modbus communication protocol, with strong anti-interference capability and stable operation[1]. It is suitable for harsh industrial environments such as petrochemical, power generation, metallurgy and water treatment, realizing stable data collection, transmission and control, and is easy to install and maintain, ensuring the continuous and stable operation of the entire control system[3].

3. Core Functional Features

  • High Reliability: Adopts industrial-grade polysilicon sensor and corrosion-resistant materials, strong anti-interference, stable measurement and signal transmission, adapting to harsh industrial on-site environments.

  • High Reliability: Adopts dual redundant power supply input and industrial-grade components, with DC1500V voltage isolation and reverse connection protection, strong anti-interference, ensuring stable operation in harsh industrial environments[2].

  • High Measurement Accuracy: Measurement accuracy up to ±0.05% of full scale, with good temperature stability, ensuring accurate data collection.

  • Multi-functional Signal Processing: 2 input channels and 4 output channels, 4-20mA standard analog output, supporting RS-485 Modbus communication, facilitating data interaction with DCS systems[1].

  • Easy Installation: Supports process direct connection or bracket installation, with various process connection options, convenient for on-site installation and debugging.

  • Easy Installation: 35mm DIN rail quick installation, clear terminal marking, convenient for on-site wiring and debugging[2].

  • Configurable & Status Monitoring: Supports configuration via system, handheld configurator or PC software, with real-time status monitoring, facilitating quick troubleshooting.

  • Intelligent Monitoring: Supports real-time status monitoring and fault alarm, with relay alarm output for power failure and fiber link failure, facilitating quick troubleshooting[2].

4. Simplified Installation Instructions

4.1 Preparation

Tools: Screwdriver, wrench, wire stripper, insulating tape; Materials: IDP10-AF1C01F transmitter (Foxboro), mounting bracket (optional), signal cables, power cables, process connection accessories.Tools: Screwdriver, wrench, wire stripper, crimping tool, insulating tape; Materials: IPM02 module (Foxboro), 35mm DIN rail, power cables, signal cables, communication cables.

4.2 Key Installation Steps

  1. Install the transmitter via process direct connection or mounting bracket, ensure it is firmly fixed, and the installation direction is consistent with the process medium flow direction.

  2. Install the IPM02 module on the 35mm DIN rail in the control cabinet, ensure it is firmly fixed, and reserve sufficient space around for heat dissipation.

  3. Cut off the power supply, connect the 24VDC~75VDC power cable and 4-20mA signal cable to the corresponding terminals (pay attention to correct polarity).

  4. Check wiring correctness and tightness, ensure no loose connections or short circuits.

  5. Power on, check the transmitter status, perform parameter configuration if needed, and confirm that the output signal is stable and the measurement data is accurate.

4.3 Key Notes

  • Install and wire by professional personnel, cut off power before operation to avoid electric shock and equipment damage.

  • Ensure correct wiring polarity, reverse polarity may damage the module.

  • Avoid installing in places with strong vibration or severe temperature changes, ensure good ventilation to ensure measurement accuracy.

  • Do not disassemble the module without authorization, which will void the product warranty.