MDX61B0008-5A3-4-0T SEW‑EURODRIVE MOVIDRIVE® MDX61B Servo Drive
Description
1.1 Product Overview
1.2 Model Code Definition
MDX61B: MOVIDRIVE® B, servo drive with IPOSplus®.
0008: 0.75 kW (1 HP) rated power.
5A3: 3‑phase 380–500 VAC input, C2 EMC filterSEW-EURODRIVE.
4: 4‑quadrant operation (integrated brake chopper).
0T: Technology version (conformal coated PCB, electronic cam, internal synchronization).
1.3 Safety Instructions
Install/service only by qualified personnel.
Disconnect power; wait ≥5 minutes for DC bus discharge.
High voltage risk; IP20 (install in cabinet).
For use with SEW DFS56L/TF/RH1M/KK servo motor.
2. Technical Specifications
2.1 Electrical Data
Rated power: 0.75 kW
Input: 3 × 380–500 VAC, 50/60 HzSEW-EURODRIVE
Input current: 2.2 A
Output: 0–500 VAC, 0–600 HzSEW-EURODRIVE
Output current: 2.4 A (cont.), 3.0 A (125% overload)
Control: Vector (VFC/CFC), V/f, servoSEW-EURODRIVE
Feedback: Resolver (RH1M), encoder (option)
Communication: RS485 (std.), expandable to fieldbus
Protection: Overcurrent, overvoltage, overtemperature, short circuit
2.2 Mechanical & Environmental
Protection: IP20
Dimensions (W×H×D): ~60 × 215 × 195 mm
Weight: ~3.0 kg
Ambient temp: 0 °C to +40 °C (operation)
Cooling: Natural convection
3. Installation
3.1 Mechanical
Mount vertically; allow ≥100 mm clearance top/bottom.
Secure with M4 screws; avoid vibration.
3.2 Electrical
Use shielded cables (power, motor, feedback)SEW-EURODRIVE.
Terminals: L1/L2/L3 (in), U/V/W (motor).
X15: Resolver (RH1M) for DFS56L motor.
TF/TH: PTC thermistor input (motor protection).
Properly ground drive and motor housing.
4. Operation
4.1 Commissioning
Use MOVITOOLS® for setup, tuning, diagnostics.
Perform motor auto‑tuning (DFS56L).
Test no‑load; check noise, vibration, temperature.
4.2 Key Functions
IPOSplus®: Integrated positioning, sequence control.
Technology functions: Electronic cam, internal synchronization.
4‑quadrant: Regenerative braking, energy recovery.
Overload: 150% for 60 s, 200% for 5 s.
5. Maintenance
Maintenance‑free under normal use.
Every 6 months:
Check cable connections/terminals.
Clean cooling vents (dry air).
Verify 24 V supply and fan (if equipped).
6. Troubleshooting
F01 Overcurrent: Short circuit, motor fault, wiring error.
F02 Overvoltage: Regenerative overload, brake chopper fault.
F08 Overtemp: Overload, blocked ventilation.
F25 Encoder fault: Resolver wiring/connection error.