DFS56L/TF/RH1M/KK SEW‑EURODRIVE Synchronous Servo Motor
Description
1. General Information
1.1 Product Overview
1.2 Model Code Definition
DFS56L: Synchronous servo motor, frame size 56, L = long stack (higher torque than DFS56H), flange‑mountedeero.
TF: PTC thermistor winding temperature protection.
RH1M: 1‑speed resolver (medium resolution), M16×1.5 connector, standard feedback.
KK: Standard power + signal connector kit.
1.3 Safety Instructions
Installation, commissioning, and maintenance must be performed by qualified personnel.
Disconnect all power before mounting, wiring, or servicing.
Contains permanent magnets; keep away from magnetic media and sensitive equipment.
Do not exceed rated voltage, current, or torque.
Protect from heavy impact, corrosive atmospheres, and excessive dust.
IP65 protection (dust‑tight, splash‑proof).
2. Technical Specifications
2.1 Electrical & Mechanical Data
Type: 3‑phase permanent magnet synchronous servo motor
Frame size: 56 (L = long stack)eero
Rated power: 0.55 kW (550 W)
Rated torque: 2.7 Nm
Rated speed: 3000 rpm
Peak torque: 7.6 Nmeero
Max speed: 6000 rpm
Voltage: 400 VAC (3‑phase)
Rated current: 2.4 A
Feedback: Resolver RH1M (1‑speed)
Thermal protection: TF (PTC thermistor)
Protection class: IP65
Shaft: Ø14 mm, keyed
Flange: B5 (IEC 56)
Weight: ~4.5 kg
Ambient temperature: ‑10 °C to +40 °C
Thermal class: F (155 °C)
3. Installation
3.1 Mechanical Mounting
Mount on a flat, rigid surface; tighten all M5 flange bolts securely.
Avoid radial/axial overload; use flexible couplings.
Allow ≥100 mm clearance for cooling and cable bending.
3.2 Electrical Connection
Use shielded cables for power and feedback (EMC compliance).
TF thermistor: Connect to drive thermal monitoring (PTC, ~1 kΩ @ 25 °C).
RH1M resolver: Connect to resolver‑compatible drive (e.g., MOVIDRIVE® MDX61B).
Properly ground the motor housing.
4. Operation
4.1 Commissioning
Run no‑load for 5–10 minutes; check for abnormal noise, vibration, or temperature rise.
Verify resolver feedback and thermal protection wiring.
Apply load gradually; monitor current and temperature.
4.2 Operating Guidelines
Operate within rated speed/torque; avoid continuous stall.
Max winding temperature: +155 °C (PTC trip).
Avoid frequent heavy start‑stops.
5. Maintenance
Lifetime grease lubrication (bearings); no regular oiling required.
Every 6 months:
Check mounting bolts and cable connections.
Clean cooling surfaces (dry air only; no high‑pressure water).
Inspect shaft seal for leaks.
Resolver is maintenance‑free.
6. Troubleshooting
No rotation: Power loss, wiring error, or drive inhibit.
Overtemp (TF): Overload, blocked ventilation, or PTC fault.
Position error: Resolver wiring fault, loose coupling, or mechanical jam.
Vibration/noise: Misalignment, loose bolts, or bearing wear.
Get a Quote