TPS10A160-NF0-503-1 MOVITRANS® Stationary Converter
May 28, 2026

TPS10A160-NF0-503-1 MOVITRANS® Stationary Converter

TPS10A160-NF0-503-1 is a 16 kW stationary high‑frequency converter by SEW‑EURODRIVE, part of the MOVITRANS® contactless energy transfer system. It converts 3‑phase 50/60 Hz AC into a 25 kHz high‑frequency AC output to supply TAS series transformer modules for contactless power transmission to mobile loads (e.g., AGVs, monorails, automated guided vehicles).

Description

1.1 Product Overview

TPS10A160-NF0-503-1 is a 16 kW stationary high‑frequency converter by SEW‑EURODRIVE, part of the MOVITRANS® contactless energy transfer system. It converts 3‑phase 50/60 Hz AC into a 25 kHz high‑frequency AC output to supply TAS series transformer modules for contactless power transmission to mobile loads (e.g., AGVs, monorails, automated guided vehicles).

1.2 Model Code Explanation

  • TPS10A: MOVITRANS stationary converter, size 4 series

  • 160: Rated power 16 kW

  • NF0: No integrated filter / basic unit, IP10 protection

  • 503: Voltage variant 3×380–500 VAC

  • 1: Standard control version

1.3 Safety Instructions

  • Installation, wiring, and servicing must be performed only by qualified electricians.

  • Disconnect all power before opening the enclosure; wait ≥ 5 minutes for DC‑link capacitors to discharge.

  • Risk of electric shock and arc flash; follow local safety regulations (e.g., IEC 60204‑1).

  • Do not exceed rated voltage/current; risk of equipment damage and fire hazard.

  • Protect from moisture, dust, and corrosive environments; indoor use only (IP10).

  • Ensure reliable protective grounding (PE).

  • Do not modify internal components or bypass safety circuits.


2. Technical Specifications

2.1 Electrical Data

  • Input: 3 × AC 380–500 V ±10%, 50/60 Hz

  • Rated Power: 16 kW

  • Output: 25 kHz high‑frequency AC (to TAS transformer)

  • Output Current: 24 A AC (25 kHz)

  • Control Supply: 24 VDC ±10%, external or internal

  • Control I/O: 1 analog input (0–10 V / 4–20 mA), 5 isolated binary inputs, 2 binary outputs

  • Protection: Overvoltage, undervoltage, overcurrent, overtemperature, short‑circuit, earth fault

  • Efficiency: ≥ 95% at full load

2.2 Mechanical & Environmental

  • Dimensions (W × H × D): 200 × 450 × 260 mm

  • Weight: approx. 28 kg

  • Protection Class: IP10 (control cabinet installation)

  • Operating Temperature: 0 °C to +40 °C

  • Storage Temperature: −25 °C to +70 °C

  • Humidity: ≤ 85% RH, non‑condensing


3. Installation

3.1 Mounting

  • Install vertically on a rigid, flat mounting plate (control cabinet recommended).

  • Maintain 150 mm clearance on all sides for cooling airflow.

  • Avoid heat sources, direct sunlight, and strong vibration.

  • Secure with M6 screws (torque: 3.0–3.5 N·m).

3.2 Wiring

  1. Main Input: Connect 3‑phase L1/L2/L3/N/PE to terminals; use 2.5–4 mm² copper cables.

  2. HF Output: Connect 25 kHz output to TAS transformer module; use shielded cables (minimum 2.5 mm²).

  3. Control Circuits: Connect 24 VDC, analog, and binary I/O; use twisted‑pair shielded cables for signals.

  4. Grounding: Ensure PE is connected first; separate signal ground from power ground.

  5. Pre‑Power Check: Verify no shorts, correct polarity, and tight terminal connections.


4. Operation

4.1 Commissioning

  1. Confirm correct wiring and grounding.

  2. Power on; check input voltage (380–500 VAC) and LED status indicators.

  3. Use MOVITOOLS® MotionStudio (SEW‑EURODRIVE software) to set parameters and diagnose faults.

  4. Run no‑load for 15 minutes; check for abnormal noise or overheating.

  5. Connect TAS transformer and mobile load; test power transfer and adjust output power as needed.

4.2 Operating Limits

  • Continuous operation: ≤ 90% load at 40 °C.

  • Do not run at full load continuously in high ambient temperatures (>35 °C).

  • If overtemperature or fault occurs, shut down immediately and troubleshoot.


5. Maintenance

  • Every 6 months:

    • Check terminals for looseness, cables for damage/aging.

    • Inspect PE connection integrity.

    • Clean dust from enclosure and ventilation slots (dry brush only).

  • Annually:

    • Verify insulation resistance (power off, discharge capacitors).

    • Check IGBTs and DC‑link capacitors for aging.

  • Use genuine SEW‑EURODRIVE parts for replacement.

  • For internal faults, contact official SEW service.


6. Troubleshooting

  • No HF output: Check 3‑phase input, fuses, enable signal, and LED fault codes.

  • Overheating: Excessive load, blocked ventilation, or ambient temperature too high.

  • Unstable HF output: Loose terminals, poor grounding, or TAS transformer mismatch.

  • Fault LED ON: Use MOVITOOLS® to read fault code (e.g., F0001 = overcurrent, F0004 = overtemperature).


7. TOP‑ANGEBOT / TOP OFFER

TOP OFFER – TPS10A160-NF0-503-1
Original SEW‑EURODRIVE MOVITRANS stationary converter, 16 kW, 3×380–500 VAC input, 25 kHz HF output. New surplus stock, 12‑month warranty, immediate delivery. Limited quantity available.

8. Disclaimer

Specifications subject to change without notice. Manufacturer is not liable for damage/injury due to improper installation, operation beyond ratings, or unauthorized modification.