TPM11B009-ENB-3A2-1
Description
1. General Information
1.1 Product Overview
1.2 Model Code Meaning
TPM11B: Series designation (MOVITRANS power converter, B‑version)
009: Power rating (900 / 1000 W)
ENB: Hardware configuration, circuit revision
3A2: Terminal assignment & electrical specification variant
1: Standard version (no options)
1.3 Safety Instructions
Only qualified electricians may install, wire, or service this unit.
Disconnect all power before opening the enclosure or performing maintenance.
Do not exceed rated voltage/current; risk of damage and fire hazard.
Protect from moisture, dust, and corrosive environments.
Ensure reliable protective grounding during operation.
Do not modify or disassemble internal components.
2. Technical Specifications
2.1 Electrical Data
Input: 135 VAC, 7.5 A, 25 kHz (high‑frequency AC)
Output: 0–200 VDC, 5 A, max. 1000 W (1 kW)
Protection: Overcurrent, overvoltage, overtemperature, short‑circuit
Auxiliary Supply: 24 VDC / 2 A (for control circuits)
2.2 Mechanical & Environmental
Dimensions: 205 × 160 × 63 mm
Weight: Approx. 1.95 kg
Protection Class: IP20 (indoor use)
Operating Temperature: 0 °C to +40 °C
Storage Temperature: −25 °C to +70 °C
Humidity: ≤ 85% RH, non‑condensing
3. Installation
3.1 Mounting
Install vertically on a rigid, flat surface.
Maintain 100 mm clearance around the unit for cooling.
Avoid heat sources, direct sunlight, and strong vibration.
Secure with appropriate screws (torque per manufacturer standard).
3.2 Wiring
Connect 135 VAC high‑frequency input to primary terminals.
Connect 0–200 VDC output to load (e.g., motor/actuator).
Connect protective earth (PE) to dedicated grounding terminal.
Connect 24 VDC control supply if required.
Use cables with sufficient cross‑section; tighten terminals to specified torque.
Verify all wiring for shorts or reverse polarity before power‑on.
4. Operation
4.1 Commissioning
Confirm correct wiring and grounding.
Power on gradually; measure input (135 VAC) and output (0–200 VDC).
Run no‑load for 5–10 minutes; check for abnormal noise or overheating.
Apply load incrementally; verify output stability.
4.2 Operating Limits
Continuous operation: ≤ 80% load at 40 °C.
Do not run at full load continuously in high ambient temperatures.
If overtemperature or fault occurs, shut down immediately.
5. Maintenance
Every 6 months:
Check terminals for looseness, cables for damage/aging.
Inspect PE connection integrity.
Clean dust from enclosure and ventilation slots (dry brush only).
No lubrication required.
Use genuine SEW‑EURODRIVE parts for replacement.
For internal faults, contact official service.
6. Troubleshooting
No DC output: Check 135 VAC input, fuses, wiring, and enable signal.
Overheating: Excessive load, blocked ventilation, or ambient temperature too high.
Unstable output: Loose terminals, poor grounding, or load mismatch.
Abnormal noise: Internal component fault; power off and inspect.