TAS10A040-N06-4X1-1 MOVITRANS® TAS10A Transformer Module(SEW‑EURODRIVE)
May 28, 2026

TAS10A040-N06-4X1-1 MOVITRANS® TAS10A Transformer Module(SEW‑EURODRIVE)

The TAS10A040-N06-4X1-1 is a compact, industrial‑grade transformer/change‑over module from SEW‑EURODRIVE’s MOVITRANS® TAS10A series. It is designed for stationary energy supply systems, providing galvanic isolation, voltage transformation, and safe switching for conveyor, automation, and drive systems.

Description

1.1 Product Overview

The TAS10A040-N06-4X1-1 is a compact, industrial‑grade transformer/change‑over module from SEW‑EURODRIVE’s MOVITRANS® TAS10A series. It is designed for stationary energy supply systems, providing galvanic isolation, voltage transformation, and safe switching for conveyor, automation, and drive systems.

1.2 Model Code Definition

  • TAS10A: Series designation (TAS = Transformer Module, 10A = Series)

  • 040: Size 2, 4 kVA nominal power

  • N06: Primary voltage 400 V AC, 50/60 Hz

  • 4X1: Secondary voltage 4 × 115 V AC

  • 1: Standard version, no options

1.3 Safety Instructions

Read all instructions before installation and operation.
Only qualified electrical personnel may install, wire, or service this module.
Disconnect all power sources before opening the housing or performing maintenance.
Do not exceed the rated voltage, current, or power ratings.
Ensure proper grounding to avoid electric shock.
Protect the module from moisture, dust, and direct sunlight.
Do not operate with damaged cables or loose connections.

2. Technical Specifications

2.1 Electrical

  • Nominal Power: 4 kVA

  • Primary Voltage: 400 V AC ±10%, 50/60 Hz

  • Secondary Voltage: 4 × 115 V AC

  • Primary Current: 10 A max

  • Secondary Current: 4 × 8.7 A max

  • Insulation Class: Class F (155 °C)

  • Dielectric Strength: 2 kV AC, 1 min (primary‑secondary)

  • Protection Class: IP20 (touch‑safe, protected against solid objects >12 mm)

2.2 Mechanical & Environmental

  • Housing: Compact metal enclosure, black painted

  • Dimensions (W×H×D): 200 mm × 150 mm × 80 mm

  • Mounting: Wall‑mount or panel‑mount (4 × M4 holes)

  • Operating Temperature: 0 °C to +40 °C

  • Storage Temperature: −25 °C to +70 °C

  • Relative Humidity: 5%–95% (non‑condensing)

  • Weight: Approx. 8 kg


3. Installation

3.1 Mechanical Mounting

Mount the module vertically on a flat, rigid wall or panel using appropriate fasteners.
Maintain a minimum clearance of 50 mm on all sides for ventilation.
Avoid mounting near heat sources or in direct airflow of cooling fans.

3.2 Electrical Connection

  • Primary Side: Connect 400 V AC supply to terminals L1, L2, L3, PE.

  • Secondary Side: Connect loads to terminals 115 V‑1, 115 V‑2, 115 V‑3, 115 V‑4, and common neutral.

  • Grounding: Ensure PE terminal is connected to protective earth.

  • Cable Size: Primary: 1.5–2.5 mm²; Secondary: 1.5 mm².

  • Torque: Tighten terminal screws to 1.2 N·m.


4. Operation

4.1 Initial Start‑Up

Verify all connections are secure and correct.
Check for short circuits on secondary side.
Apply primary power and measure secondary voltages (should be 115 V ±5% per channel).
No load operation: Allow 5 min warm‑up; check for abnormal noise or overheating.

4.2 Operating Limits

Do not exceed 4 kVA total secondary load.
Avoid continuous operation at 100% load above 35 °C ambient.
Switch off power if overheating, unusual noise, or smoke occurs.

5. Maintenance

5.1 Regular Inspection

Every 6 months:
  • Check all terminals for tightness and corrosion.

  • Clean dust from ventilation slots with a dry brush.

  • Inspect cables for damage or aging.

5.2 Lubrication

No lubrication required; the module is maintenance‑free under normal conditions.

5.3 Replacement Parts

Use only genuine SEW‑EURODRIVE replacement components.
Contact SEW service for transformer winding or housing replacement.

6. Troubleshooting

  • No secondary voltage: Check primary power, fuse, and wiring; verify terminal connections.

  • Low secondary voltage: Overloaded secondary circuit; reduce load.

  • Overheating: Insufficient ventilation, overloaded, or shorted secondary.

  • Abnormal hum: Loose core, damaged winding, or incorrect voltage.


7. Ordering Information

  • Model: TAS10A040-N06-4X1-1

  • Accessories: Mounting brackets, cable glands, protective covers available separately.


8. Disclaimer

Specifications are subject to change without notice. SEW‑EURODRIVE assumes no liability for damage or injury resulting from improper installation, misuse, or operation beyond rated parameters.


Get a Quote