MM22D-503 (SEW-EURODRIVE MOVIMOT D-series)
Description
1. Product Overview
2. Model Code Explanation
MM: MOVIMOT decentralized drive
22: Rated power 2.2 kW
D: D‑series (latest generation)
503: 3‑phase 380–500 V AC
‑00: Standard version; ‑03: STO safety; ‑30: AS‑Interface
Part number: 18215041
3. Technical Specifications
3.1 Electrical
Input Voltage: 3×380–500 V AC ±10%, 50/60 Hz
Rated Input Current: 5.0 A
Rated Output Power: 2.2 kW
Rated Output Current: 5.5 A
Output Frequency: 2–100 Hz
Control Modes: V/F + vector control (improved low‑speed torque)
Communication: RS‑485/Modbus RTU (standard); AS‑Interface (‑30)
Digital I/O: 4DI / 2DO (24 V DC)
Brake Control: Integrated (for SEW brake motors)
Overload Capacity: 150% for 60 s
EMC Filter: Built‑in Class A filter (no external filter needed)
PWM Frequency: 16 kHz (low noise)
3.2 Mechanical & Environmental
Protection Class: IP55
Cooling: Natural convection (optimized heatsink)
Dimensions (W×H×D): ~160 × 210 × 110 mm
Weight: 2.3 kg
Operating Temperature: ‑30 °C … +40 °C
Storage Temperature: ‑25 °C … +70 °C
4. Key Features (vs B/C‑series)
Built‑in EMC filter: Reduces installation cost
16 kHz PWM: Near‑silent operation (quieter than B‑series 8 kHz / C‑series 12 kHz)
Extended low‑temp range: Down to ‑30 °C (vs ‑25 °C for B/C)
Enhanced vector control: Better low‑speed torque
STO safety option: Available (‑03 model)
Drop‑in compatible: Same mounting/wiring as MM22B/22C‑503
5. Product Status & Replacement
MM22D‑503: In production, current standard model
Replaces: MM22B‑503 (discontinued), MM22C‑503 (discontinued)
6. Typical Applications
Logistics conveyor lines & sortation systems
Packaging machinery & material handling
Industrial fans, pumps & general automation
Retrofit of older B/C‑series systems
7. Installation & Wiring
7.1 Mechanical
Mount directly to SEW DRS/DRE/DRP motor flange
Tighten mounting screws to 3.5 Nm
Keep heatsink clear for airflow
7.2 Electrical
Power: L1/L2/L3/PE → 3×380–500 V AC, reliable earth
Motor: U/V/W/PE → shielded cable to motor terminals
Control: 24 V DC, run/stop, direction, reset
Communication: RS‑485 for Modbus RTU
EMC: No external filter required (internal Class A fitted)
8. Commissioning
Check wiring/insulation before power‑on
Set motor parameters, I/O logic, comm address via DIP switches
Power on: steady green LED = standby
Low‑speed test run; check noise/vibration, then ramp to speed
9. Status & Faults
9.1 LED Indications
Steady green: Ready
Flashing green: Running
Flashing red: Fault
9.2 Common Faults
Overcurrent: Short circuit, overload, motor fault
Overvoltage: Supply surge, regenerative voltage
Overtemperature: Blocked cooling, high ambient
Communication error: Bad RS‑485 cable, wrong address
10. Maintenance
Clean heatsink every 6 months
Check terminal tightness & cable condition
Replace seals if damaged (maintain IP55)
11. Storage & Disposal
Store in dry, clean environment within temp range
Dispose per WEEE regulations; recycle metals, plastics, electronics
Get a Quote