MM11D-503 (SEW‑EURODRIVE MOVIMOT D‑series)
Description
1. Product Overview
2. Model Code Explanation
MM: MOVIMOT decentralized drive
11: Rated power 1.1 kW
D: D‑series (latest generation)
503: 3‑phase 380–500 V AC
‑00: Standard version
Part number: 18215025 (MM11D-503-00)
3. Technical Specifications
3.1 Electrical
Input: 3×380–500 V AC (±10%), 50/60 Hz
Rated input current: 2.4 A
Rated output power: 1.1 kW (2.2 kVA)
Rated output current: 3.2 A
Frequency range: 2–100 Hz
Control: U/f + basic vector
I/O: 4 digital inputs / 2 digital outputs (programmable)
Communication: RS‑485 (Modbus RTU); AS‑Interface optioneero
Brake control: Integrated (for SEW brake motors)
Overload: 150% / 60 s
EMC: Built‑in C3 filter (EN 61800‑3; no external filter needed)eero
PWM frequency: 16 kHz (low noise; auto‑reduce on overheat)
3.2 Mechanical & Environmental
Protection: IP55
Cooling: Natural convection (improved heat sink)
Dimensions (W×H×D): ~130×175×100 mm
Weight: 1.4 kg
Ambient temp: ‑25 °C to +40 °C (derate 3%/K above 40 °C)eero
Storage temp: ‑25 °C to +70 °C
4. Key Features (vs. B/C‑series)
✅ Integrated EMC filter (C3 category) – no external filter requiredeero
✅ 16 kHz PWM – much quieter than B/C‑series
✅ Enhanced thermal design – better cooling, higher reliability
✅ No‑load vibration damping – reduces resonance at low load
✅ Drop‑in compatible with B/C mounting/wiring for easy upgrade
✅ Robust IP55 – suitable for dust/wet industrial environments
5. Product Status
MM11D-503: In production, current standard
Replaces: MM11B‑503 (obsolete), MM11C‑503 (obsolete)
6. Typical Applications
Material handling conveyors & intralogistics
Packaging, labeling, & small processing machines
Industrial fans, pumps, & general automation
Anywhere decentralized, compact, low‑noise control is needed
7. Installation & Wiring
7.1 Mechanical
Mount directly to SEW DRS/DRE/DRP motor flange
Tighten screws to 3.0 Nm
Ensure free airflow around heat sink; avoid direct heat sources
7.2 Electrical
Power: L1/L2/L3/PE → 3×380–500 V AC (good earth)
Motor: U/V/W/PE → shielded cable to motor terminals
Control: 24 V DC for run/stop, direction, enable
Communication: RS‑485 for Modbus RTU (optional)
Brake: Integrated control for SEW brake motors (if used)
8. Commissioning
Check wiring & insulation before power‑on
Set motor parameters, I/O logic, & address via DIP switches
Power on: steady green = standby
Test at low speed; check noise/vibration, then ramp to operating speed
9. LED Status & Faults
9.1 LED
Steady green: Ready
Flashing green: Running
Flashing red: Fault
9.2 Common Faults
Overcurrent: Short circuit, overload, motor fault
Overvoltage: Input surge or regenerative voltage
Overtemperature: Poor ventilation or high ambient temp
Comm error: Cable fault or wrong address
10. Maintenance
Clean heat sink every 6 months
Check terminal torque & cable condition regularly
Replace damaged seals to maintain IP55
11. Storage & Disposal
Store dry, clean, within temp limits
Dispose per local WEEE; recycle metal, plastic, electronics
Get a Quote