MM11B-503
Description
1. Product Overview
2. Model Code Explanation
MM: MOVIMOT decentralized drive
11: Rated power 1.1 kW
B: B‑series (older generation)
503: 3‑phase 380–500 V AC
-00: Standard version
Part number: Typically 824118X (varies by revision)
3. Technical Specifications
3.1 Electrical Parameters
Input Voltage: 3×380–500 V AC (±10%), 50/60 Hz
Rated Input Current: 2.4 A
Rated Output Power: 1.1 kW
Rated Output Current: 3.2 A
Output Frequency Range: 2–100 Hz
Control Modes: U/f control (basic)
Digital I/O: 4 inputs / 2 outputs (programmable)
Communication: RS‑485 (Modbus RTU, optional)
Brake Control: Integrated (for SEW brake motors)
Overload Capacity: 150% for 60 seconds
EMC: External EMC filter required (not built‑in)
3.2 Mechanical & Environmental Parameters
Protection Class: IP55
Cooling Method: Natural convection
Dimensions (W × H × D): Approx. 130 × 175 × 100 mm
Weight: 1.4 kg
Operating Temperature: ‑25 °C to +40 °C
Storage Temperature: ‑25 °C to +70 °C
4. Main Features
Compact, motor‑mounted design saves cabinet space.
Simple U/f control for standard induction motors.
Integrated brake control for SEW brake motors.
Robust IP55 enclosure for harsh industrial environments.
Lower noise than direct‑on‑line starters.
Note: Requires external EMC filter to meet EMC standards.
5. Product Status & Replacement
MM11B‑503: Obsolete, no longer in production.
Direct Replacements: MM11C‑503 (C‑series) or MM11D‑503 (D‑series, latest).
The D‑series adds a built‑in EMC filter, improved thermal performance, and wider frequency range.
6. Typical Applications
Material handling conveyors
Packaging and labeling machines
Small fans and pumps
General automation machinery
7. Installation & Wiring
7.1 Mechanical Installation
Mount directly on SEW DRS/DRE/DRP series motor flange.
Tighten mounting screws to 3.0 Nm.
Ensure adequate ventilation; avoid heat sources.
7.2 Electrical Wiring
Power (L1/L2/L3/PE): 3‑phase 380–500 V AC, proper grounding.
Motor (U/V/W/PE): Shielded cable to motor terminals.
Control: 24 V DC for run/stop, direction, enable.
Communication: RS‑485 for Modbus RTU (optional).
EMC: Install external EMC filter on input side.
8. Commissioning
Verify all wiring and insulation before power‑on.
Set motor parameters and control logic via DIP switches.
Power on; steady green LED indicates standby.
Test run at low speed; check for noise/vibration, then ramp to speed.
9. Status & Faults
9.1 LED Indications
Steady green: Ready
Flashing green: Running
Flashing red: Fault
9.2 Common Faults
Overcurrent: Short circuit, overload, or motor fault.
Overvoltage: Input surge or regenerative voltage.
Overtemperature: Poor ventilation or high ambient temp.
Communication error: Cable fault or wrong address.
10. Maintenance
Clean heat sink every 6 months.
Check terminal tightness and cable condition regularly.
Replace damaged seals to maintain IP55.
11. Storage & Disposal
Store in dry, clean environment within temperature limits.
Dispose per local WEEE regulations; recycle metal, plastic, electronics.