MM07B‑503 (SEW MOVIMOT B‑Series, 0.75 kW)
Description
1. Product Overview
2. Model Code
MM: MOVIMOT decentralized drive
07: 0.75 kW rated power
B: B‑series (compact, mid‑generation)
503: 3‑phase 380–500 V AC
‑00: standard version
Part number: 8230242
3. Technical Specifications
3.1 Electrical
Input: 3×380–500 V AC (±10%), 50/60 Hz
Rated input current: 1.9 A
Rated output power: 0.75 kW
Rated output current: 2.5 A
Output frequency: 2–100 Hz
Control modes: U/f, basic vector (VFC)
Digital I/O: 4 programmable inputs / 2 programmable outputs
Communication: RS‑485 (Modbus RTU optional)
Brake control: integrated (for SEW brake motors)
Overload: 150% for 60 s
EMC: no integrated filter (external filter required)
3.2 Mechanical & Environmental
Protection class: IP55
Cooling: natural convection
Dimensions (W×H×D): approx. 135 × 182 × 105 mm
Weight: 2.9 kg
Operating temperature: ‑25 °C to +40 °C
Storage temperature: ‑25 °C to +70 °C
4. Key Features
Compact design: direct motor mounting saves cabinet space.
Programmable I/O: flexible for on‑site logic and sensor connection.
Integrated brake control: works with SEW brake motors for stopping/holding.
Simple commissioning: DIP switches for basic setup; optional software for advanced parameters.
Cost‑effective: reliable for standard applications without Ethernet needs.
5. Status & Replacement
MM07B‑503: discontinued (B‑series phased out).
Replacement: MM07D‑503‑00 (D‑series, integrated EMC filter, Ethernet option, higher performance).
6. Typical Applications
Logistics conveyors, material handling systems
Packaging machinery, small processing lines
Fans, pumps, and general‑purpose automation
7. Installation & Wiring
7.1 Mechanical
Mount directly on SEW motor flange (DRS/DRE series).
Tighten mounting screws to 3.0 Nm.
Ensure unobstructed airflow; avoid direct heat sources.
7.2 Electrical
Power (L1/L2/L3/PE): 3‑phase 380–500 V AC, reliable earth connection.
Motor (U/V/W/PE): shielded cable to motor terminals.
Control: 24 V DC for run/stop, direction, and enable signals.
Communication: RS‑485 for networking (optional Modbus RTU).
8. Commissioning
Check wiring and insulation before applying power.
Set motor parameters, control mode, and address via DIP switches.
Power on; steady green LED indicates standby.
Test run at low speed; check for noise or vibration, then ramp to operating speed.
9. Status & Faults
9.1 LED Indications
Steady green: ready/standby
Flashing green: running
Flashing red: fault (overcurrent, overvoltage, overtemperature, communication error)
9.2 Common Faults
Overcurrent: short circuit, overload, or motor winding fault.
Overvoltage: input voltage surge or regenerative voltage from the motor.
Overtemperature: poor ventilation or ambient temperature exceeding +40 °C.
Communication error: faulty RS‑485 cable, incorrect address, or network mismatch.
10. Maintenance
Clean heat sink and dust buildup every 6 months.
Check terminal tightness and cable insulation regularly.
Replace damaged seals or cables to maintain IP55 protection.
11. Storage & Disposal
Store in a dry, clean area at ‑25 °C to +70 °C.
Dispose of according to local WEEE regulations; recycle metals, plastics, and electronic components.
Get a Quote