MM05C-503 (SEW MOVIMOT C‑Series)
Description
1. Product Overview
2. Model Code
MM: MOVIMOT decentralized drive
05: 0.55 kW rated power
C: C‑series (compact, upgraded)
503: 3‑phase 380–500 V AC
‑00: standard version
Part number: 8241163
3. Technical Specifications
3.1 Electrical
Input: 3×380–500 V AC (±10%), 50/60 Hz
Rated input current: 1.6 A
Rated output power: 0.55 kW
Rated output current: 2.0 A
Output frequency: 2–100 Hz
Control: U/f, basic vector (VFC)
I/O: 4 digital inputs / 2 digital outputs (programmable)
Communication: RS‑485 (optional)
Brake: integrated brake control (for SEW brake motors)
Overload: 150% for 60 s
EMC: integrated EMC filter
3.2 Mechanical & Environmental
Protection: IP55
Cooling: natural convection
Dimensions (W×H×D): approx. 135 × 182 × 105 mm
Weight: 2.9 kg
Ambient temperature: ‑25 °C to +40 °C
4. Key Features
Compact design: smaller than B‑series, direct motor mounting saves cabinet space.
Integrated EMC filter: reduces interference, meets industrial EMC standards.
Enhanced safety: optional STO (Safe Torque Off) available.
Flexible I/O: programmable digital I/O for on‑site logic.
Simple commissioning: DIP switches for basic setup; optional software for advanced parameters.
5. Comparison with Related Series
MM05A: older, lower output current (2.0 A fixed), no EMC filter, fixed I/O.
MM05B: transitional, 2.5 A output current, programmable I/O, no integrated EMC filter.
MM05C: compact, integrated EMC filter, optional STO, discontinued.
MM05D: latest replacement for C‑series, extended functions, Ethernet option.
6. Typical Applications
Logistics conveyors, production lines
Packaging machinery, material handling
Small fans, pumps, general automation
7. Installation & Wiring
7.1 Mechanical
Mount directly on SEW motor flange.
Tighten screws to 3.0 Nm.
Ensure clear ventilation; avoid direct heat.
7.2 Electrical
Power (L1/L2/L3/PE): 3‑phase 380–500 V AC, reliable earth.
Motor (U/V/W/PE): shielded cable to motor.
Control: 24 V DC, run/stop, direction signals.
Communication: RS‑485 for networking (optional).
7.3 EMC
Shielded motor/signal cables; ground both ends.
Separate power and signal cables.
8. Commissioning
Check wiring/insulation before power‑on.
Set mode, motor parameters, address via DIP switches.
Power on; green LED = standby.
Test run at low speed; check noise/vibration, then ramp up.
9. Status & Faults
9.1 LED Indications
Steady green: ready
Flashing green: running
Flashing red: fault
9.2 Common Faults
Overcurrent: short circuit, overload, motor fault.
Overvoltage: input surge, regenerative voltage.
Overtemperature: poor ventilation, high ambient temp.
Comm error: RS‑485 cable fault, wrong address.
10. Maintenance
Clean dust/heat sink every 6 months.
Check terminal tightness and cable condition regularly.
Replace aged cables/seals as needed.
11. Storage & Disposal
Store dry/clean, ‑25 °C to +70 °C.
Dispose per local WEEE regulations; recycle metals, plastics, electronics.