MM03D-503 (SEW MOVIMOT D‑series)
Description
1. Product Overview
2. Model Code Meaning
MM: MOVIMOT decentralized drive
03: Rated motor power 0.37 kW
D: D‑series (enhanced version over C‑series)
503: 3‑phase 380–500 V AC supply
‑00: Standard version (full model: MM03D‑503‑00)eero
Part number: 18214991eero
3. Key Technical Data
3.1 Electrical
Input: 3×380–500 V AC (±10%), 50/60 Hz
Rated input current: 1.3 A
Rated output power: 0.37 kW
Rated output current: 1.6 A (higher than MM03C’s 1.3 A)eero
Output frequency: 2–120 Hzeero
Control: Vector (VFC) / U/f selectable
I/O: 4 digital inputs / 2 digital outputs (programmable)
Communication: RS‑485 (standard)
Safety: Optional STO (Safe Torque Off)
Brake: Integrated brake control (for SEW brake motors)
Overload: 150% for 60 s, 175% for 2 s
3.2 Mechanical & Environmental
Protection class: IP55 (IP66 optional for food & beverage)
Cooling: Natural convection
Dimensions (W×H×D): ~120 × 180 × 80 mm
Weight: ~2.7 kg
Operating temperature: ‑30 °C to +40 °C (wider than MM03C)
Storage temperature: ‑25 °C to +70 °C
4. Main Features (vs. MM03C)
Higher output current: 1.6 A vs 1.3 A → better overload capabilityeero.
Wider ambient range: ‑30 °C cold start capable.
Improved thermal design: More robust heat sink, better for continuous duty.
16 kHz PWM: Quieter operation, lower audible noise.
4‑quadrant operation: Standard, supports motoring/regenerative modes.
Integrated EMC filter: Reduces external interference.
5. Typical Applications
Conveyors (logistics, food, automotive)
Packaging machines
Material handling
Fans/pumps (variable speed)
General automation with decentralized drives
6. Installation & Wiring
6.1 Mechanical
Mount directly on SEW motor flange (torque 3.0 Nm).
Keep ventilation area clear; avoid heat sources.
6.2 Electrical
Power: L1/L2/L3/PE → 380–500 V AC
Motor: U/V/W/PE → shielded cable
Control (X6): 24 V DC, direction, enable, fault
RS‑485 (X50): For setup and networking
7. Commissioning (Simplified)
Check wiring and insulation.
Set DIP switches (address, brake mode, control mode).
Adjust potentiometers:
f1: Max frequency
f2: Min frequency
t1: Ramp time
Power on; green LED = ready.
Test run at low speed, then ramp up.
8. Status & Faults (3‑color LED)
Green steady: Ready
Green flash: Running
Red flash: Fault (overcurrent, overvoltage, overtemperature, comms error)
Yellow: Warning (e.g., overheat pre‑alarm)
9. Maintenance
Clean heat sink every 6 months.
Check terminal torque (0.8–1.5 Nm).
Update firmware via MOVITOOLS®.
Get a Quote