MDX61B0005-5A3-4-00 MOVIDRIVE® B Series AC Drive | SEW-EURODRIVE
May 28, 2026

MDX61B0005-5A3-4-00 MOVIDRIVE® B Series AC Drive | SEW-EURODRIVE

MDX61B0005-5A3-4-00 MOVIDRIVE® B Series AC Drive | SEW-EURODRIVE

Description

1. General Description

MDX61B0005-5A3-4-00 is a 0.55 kW (Constant Torque) compact AC drive from SEW-EURODRIVE MOVIDRIVE® MDX61B series. It is fitted with an integrated brake chopper for four-quadrant regenerative operation. This model is designed with built-in EMC filter and features standard non-coated PCB for clean, dry industrial environments.

2. Model Code Explanation

  • MDX61B: MOVIDRIVE B series, dual expansion slots for encoder and fieldbus modules

  • 0005: Rated power 0.55 kW (Constant Torque)

  • 5A3: 3-phase 380–500 V AC, with integrated EMC filter

  • 4: Integrated brake chopper, supports four-quadrant regenerative operation

  • 00: Standard non-coated PCB

3. Technical Specifications

3.1 Electrical Parameters

  • Input Voltage: 3×380–500 V AC (-15% ~ +10%), 50/60 Hz

  • Rated Input Current: 1.6 A (at 400 V)

  • Rated Output Power: 0.55 kW (CT)

  • Rated Output Current: 1.5 A

  • Output Frequency Range: 0–599 Hz

  • Control Modes: V/f control, VFC vector control, CFC closed-loop vector control, servo control

  • Overload Capability: 150% rated current for 60 s; 200% rated current for 2 s

  • Switching Frequency: 4 kHz, 8 kHz, 12 kHz, 16 kHz (adjustable)

  • Safety Function: STO (Safe Torque Off), compliant with PL d / SIL 2

3.2 Mechanical & Environmental Parameters

  • Protection Class: IP20 (cabinet installation only)

  • Dimensions (W × H × D): 70 × 155 × 160 mm

  • Weight: Approximately 1.1 kg

  • Operating Temperature: 0 °C to +40 °C. Power derating is required when ambient temperature exceeds 40 °C.

  • Storage Temperature: -25 °C to +70 °C

  • Altitude: No power derating below 1000 m; derate 1% per additional 100 m above 1000 m

  • Certifications: CE, UL, RoHS, EAC

4. Version Comparison

  • 00: Standard non-coated PCB, for clean and dry environments

  • 0T: Conformal coated PCB, for humid, dusty or mildly corrosive environments

  • 5A3: With built-in EMC filter; 503: Without built-in EMC filter

5. Main Features

  1. Integrated EMC filter simplifies on-site wiring and meets electromagnetic compatibility requirements directly.

  2. Built-in brake chopper enables four-quadrant operation, regenerative braking and energy recovery.

  3. Compact structure saves installation space for small-power applications.

  4. Modular design supports optional encoder and various fieldbus modules for function expansion.

  5. Integrated IPOSplus® motion system realizes positioning, electronic gearing and master-slave synchronization.

  6. Standard STO safety function complies with international machine safety standards.

6. Installation & Wiring

  • Mounting Method: Vertical installation inside control cabinet.

  • Ventilation Clearance: Minimum 50 mm space at top and bottom, 30 mm on both sides.

  • Main Terminals:

    • X1: Mains connection (L1, L2, L3, PE)

    • X2: Motor connection (U, V, W, PE)

    • X4: DC link terminals for external brake resistor

    • X11: Analog input (0–10 V / 4–20 mA)

    • X13: 24 V DC digital inputs and outputs

    • X15 / X16: Encoder interfaces

7. Operation & Commissioning

  • Local Operation: DBG60B handheld keypad for parameter setting, manual operation and fault checking.

  • PC Commissioning: MOVITOOLS® MotionStudio for program editing, real-time monitoring and fault diagnosis.

  • Operating Modes: Jog mode, reference homing, positioning mode, synchronous operation.

8. Safety Instructions

  • Installation, wiring and commissioning shall only be performed by qualified electrical personnel.

  • High residual voltage remains inside the drive after power-off. Wait at least 5 minutes for full capacitor discharge before touching internal terminals.

  • Use shielded cables for motor and signal wiring.

9. Maintenance & Troubleshooting

  • Routine Maintenance: Regularly inspect cable connections and ventilation passages. Remove dust with dry compressed air.

  • Typical Faults: Overcurrent (OC), Overvoltage (OV), Overtemperature (OT), Encoder Error. Fault codes can be checked via keypad or supporting software.

10. Typical Applications

  • Small conveyors, auxiliary production equipment

  • Packaging machinery, small automated assembly lines

  • Mini fans, small pumps and light-duty industrial devices

  • General indoor industrial environments with clean and dry conditions


Get a Quote