MDX61B0005-5A3-4-00 MOVIDRIVE® B Series AC Drive | SEW-EURODRIVE
Description
1. General Description
2. Model Code Explanation
MDX61B: MOVIDRIVE B series, dual expansion slots for encoder and fieldbus modules
0005: Rated power 0.55 kW (Constant Torque)
5A3: 3-phase 380–500 V AC, with integrated EMC filter
4: Integrated brake chopper, supports four-quadrant regenerative operation
00: Standard non-coated PCB
3. Technical Specifications
3.1 Electrical Parameters
Input Voltage: 3×380–500 V AC (-15% ~ +10%), 50/60 Hz
Rated Input Current: 1.6 A (at 400 V)
Rated Output Power: 0.55 kW (CT)
Rated Output Current: 1.5 A
Output Frequency Range: 0–599 Hz
Control Modes: V/f control, VFC vector control, CFC closed-loop vector control, servo control
Overload Capability: 150% rated current for 60 s; 200% rated current for 2 s
Switching Frequency: 4 kHz, 8 kHz, 12 kHz, 16 kHz (adjustable)
Safety Function: STO (Safe Torque Off), compliant with PL d / SIL 2
3.2 Mechanical & Environmental Parameters
Protection Class: IP20 (cabinet installation only)
Dimensions (W × H × D): 70 × 155 × 160 mm
Weight: Approximately 1.1 kg
Operating Temperature: 0 °C to +40 °C. Power derating is required when ambient temperature exceeds 40 °C.
Storage Temperature: -25 °C to +70 °C
Altitude: No power derating below 1000 m; derate 1% per additional 100 m above 1000 m
Certifications: CE, UL, RoHS, EAC
4. Version Comparison
00: Standard non-coated PCB, for clean and dry environments
0T: Conformal coated PCB, for humid, dusty or mildly corrosive environments
5A3: With built-in EMC filter; 503: Without built-in EMC filter
5. Main Features
Integrated EMC filter simplifies on-site wiring and meets electromagnetic compatibility requirements directly.
Built-in brake chopper enables four-quadrant operation, regenerative braking and energy recovery.
Compact structure saves installation space for small-power applications.
Modular design supports optional encoder and various fieldbus modules for function expansion.
Integrated IPOSplus® motion system realizes positioning, electronic gearing and master-slave synchronization.
Standard STO safety function complies with international machine safety standards.
6. Installation & Wiring
Mounting Method: Vertical installation inside control cabinet.
Ventilation Clearance: Minimum 50 mm space at top and bottom, 30 mm on both sides.
Main Terminals:
X1: Mains connection (L1, L2, L3, PE)
X2: Motor connection (U, V, W, PE)
X4: DC link terminals for external brake resistor
X11: Analog input (0–10 V / 4–20 mA)
X13: 24 V DC digital inputs and outputs
X15 / X16: Encoder interfaces
7. Operation & Commissioning
Local Operation: DBG60B handheld keypad for parameter setting, manual operation and fault checking.
PC Commissioning: MOVITOOLS® MotionStudio for program editing, real-time monitoring and fault diagnosis.
Operating Modes: Jog mode, reference homing, positioning mode, synchronous operation.
8. Safety Instructions
Installation, wiring and commissioning shall only be performed by qualified electrical personnel.
High residual voltage remains inside the drive after power-off. Wait at least 5 minutes for full capacitor discharge before touching internal terminals.
Use shielded cables for motor and signal wiring.
9. Maintenance & Troubleshooting
Routine Maintenance: Regularly inspect cable connections and ventilation passages. Remove dust with dry compressed air.
Typical Faults: Overcurrent (OC), Overvoltage (OV), Overtemperature (OT), Encoder Error. Fault codes can be checked via keypad or supporting software.
10. Typical Applications
Small conveyors, auxiliary production equipment
Packaging machinery, small automated assembly lines
Mini fans, small pumps and light-duty industrial devices
General indoor industrial environments with clean and dry conditions