MDX61B1320-503-4-00 MOVIDRIVE® B Series AC Drive | SEW-EURODRIVE
May 28, 2026

MDX61B1320-503-4-00 MOVIDRIVE® B Series AC Drive | SEW-EURODRIVE

MDX61B1320-503-4-00 is a 132 kW (Constant Torque) high-power AC drive from SEW-EURODRIVE MOVIDRIVE® MDX61B series. It is fitted with an integrated brake chopper for four-quadrant regenerative operation. There is no built-in EMC filter, so an external EMC filter is required. The suffix 00 means standard non-coated PCB, designed for clean and dry industrial environments.

Description

1. General Description

MDX61B1320-503-4-00 is a 132 kW (Constant Torque) high-power AC drive from SEW-EURODRIVE MOVIDRIVE® MDX61B series. It is fitted with an integrated brake chopper for four-quadrant regenerative operation. There is no built-in EMC filter, so an external EMC filter is required. The suffix 00 means standard non-coated PCB, designed for clean and dry industrial environments.

2. Model Code Explanation

  • MDX61B: MOVIDRIVE B series, equipped with dual expansion slots for encoder and fieldbus modules

  • 1320: Rated power 132 kW (Constant Torque)

  • 503: 3-phase 380–500 V AC, no integrated EMC filter

  • 4: Integrated brake chopper, supports four-quadrant regenerative operation

  • 00: Standard non-coated PCB

3. Technical Specifications

3.1 Electrical Parameters

  • Input Voltage: 3×380–500 V AC (-15% ~ +10%), 50/60 Hz

  • Rated Input Current: 225 A (at 400 V)

  • Rated Output Power: 132 kW (CT)

  • Rated Output Current: 250 A

  • Apparent Power: 174 kVA

  • Output Frequency Range: 0–400 Hz

  • Control Modes: V/f control, VFC vector control, CFC closed-loop vector control, servo control

  • Overload Capability: 150% rated current for 60 s; 175% rated current for 2 s

  • Switching Frequency: 4 kHz, 8 kHz, 12 kHz, 16 kHz (adjustable)

  • Safety Function: STO (Safe Torque Off), compliant with PL d / SIL 2

3.2 Mechanical & Environmental Parameters

  • Protection Class: IP20 (cabinet installation only)

  • Dimensions (W × H × D): 350 × 850 × 370 mm

  • Weight: Approximately 72 kg

  • Operating Temperature: 0 °C to +40 °C. Power derating is required when ambient temperature exceeds 40 °C.

  • Storage Temperature: -25 °C to +70 °C

  • Altitude: No power derating below 1000 m; derate 1% per additional 100 m above 1000 m

  • Certifications: CE, UL, RoHS, EAC

4. Version Comparison

  • 00: Standard non-coated PCB, for clean and dry environments

  • 0T: Conformal coated PCB, for humid, dusty or mildly corrosive environments

  • 50: Special factory customized version

5. Main Features

  1. Four-quadrant operation with built-in brake chopper enables regenerative braking and energy recovery.

  2. External EMC filter must be installed to meet electromagnetic compatibility standards.

  3. Modular design supports optional encoder and various fieldbus modules for function expansion.

  4. Integrated IPOSplus® motion system realizes positioning, electronic gearing and master-slave synchronization.

  5. Standard PCB ensures stable performance under normal industrial conditions.

  6. STO safety function complies with international machine safety regulations.

6. Installation & Wiring

  • Mounting Method: Vertical installation inside control cabinet.

  • Ventilation Clearance: Keep minimum 100 mm space at top and bottom, 50 mm on both sides.

  • Main Terminals:

    • X1: Mains connection (L1, L2, L3, PE)

    • X2: Motor connection (U, V, W, PE)

    • X4: DC link terminals for external brake resistor

    • X11: Analog input (0–10 V / 4–20 mA)

    • X13: 24 V DC digital inputs and outputs

    • X15 / X16: Encoder interfaces

7. Operation & Commissioning

  • Local Operation: DBG60B handheld keypad for parameter setting, manual operation and fault checking.

  • PC Commissioning: MOVITOOLS® MotionStudio for program editing, real-time monitoring and fault diagnosis.

  • Operating Modes: Jog mode, reference homing, positioning mode, synchronous operation.

8. Safety Instructions

  • Installation, wiring and commissioning shall only be performed by qualified electrical personnel.

  • High residual voltage remains inside the drive after power-off. Wait at least 5 minutes for full capacitor discharge before touching internal terminals.

  • Use shielded cables for motor and signal wiring, and match with a qualified external EMC filter.

9. Maintenance & Troubleshooting

  • Routine Maintenance: Regularly inspect cable connections and ventilation passages. Remove dust with dry compressed air.

  • Typical Faults: Overcurrent (OC), Overvoltage (OV), Overtemperature (OT), Encoder Error. Fault codes can be checked via keypad or supporting software.

10. Typical Applications

  • Heavy-duty conveyors, large cranes and hoists

  • Heavy industrial production machinery

  • Large fans, water pumps and process equipment

  • General industrial sites with clean and dry operating conditions


Get a Quote