MDX61B0550-503-4-00 MOVIDRIVE® B Series AC Drive | SEW‑EURODRIVE
Description
1. General Description
2. Model Code Breakdown
MDX61B: MOVIDRIVE B series, dual expansion slots (encoder + fieldbus)
0550: Rated power 55 kW (CT)
503: 3‑phase 380–500 V AC, no integrated EMC filter
4: Integrated brake chopper, four‑quadrant regenerative
00: Standard non‑coated PCB
3. Technical Specifications
3.1 Electrical Data
Input Voltage: 3×380–500 V AC (‑15% ~ +10%), 50/60 Hz
Rated Input Current: 94.5 A (at 400 V)
Rated Output Power: 55 kW (CT)
Rated Output Current: 105 A
Apparent Power: 73.5 kVA
Output Frequency: 0–599 Hz
Control Modes: V/f, VFC vector, CFC closed‑loop vector, servo
Overload: 150% / 60 s; 175% / 2 s
Switching Frequency: 4/8/12/16 kHz (adjustable)
Safety: STO (Safe Torque Off), PL d / SIL 2
3.2 Mechanical & Environmental
Protection Class: IP20 (cabinet‑only)
Dimensions (W×H×D): 280 × 610 × 330 mm
Weight: ≈ 32.7 kg
Operating Temp: 0 °C to +40 °C (derate >40 °C)
Storage Temp: ‑25 °C to +70 °C
Altitude: ≤1000 m no derating; ‑1% / 100 m above 1000 m
Certifications: CE, UL, RoHS, EAC
4. Version Variants
00: Standard non‑coated PCB (clean/dry areas)
0T: Conformal coated PCB (humid/dusty/corrosive)
50: Factory‑special version
5. Key Features
Four‑Quadrant Operation: Built‑in brake chopper enables regenerative braking and energy recovery.
External EMC Design: Requires external EMC filter for compliance.
Modular Expansion: Add encoder (e.g., DEU21B) and fieldbus modules (PROFIBUS, EtherCAT, CANopen).
Integrated Motion: IPOSplus® for positioning, electronic gearing, master‑slave sync.
Standard PCB: Cost‑effective for typical industrial conditions.
STO Safety: Meets PL d / SIL 2 requirements.
6. Installation & Wiring
Mounting: Vertical in control cabinet.
Clearance: 100 mm top/bottom, 50 mm sides.
Main Terminals:
X1: Mains (L1, L2, L3, PE)
X2: Motor (U, V, W, PE)
X4: DC link for external brake resistor
X11: Analog input (0–10 V / 4–20 mA)
X13: 24 V DC digital I/O
X15/X16: Encoder interfaces
7. Operation & Commissioning
Local: DBG60B keypad for parameters, jog, fault diagnosis.
PC: MOVITOOLS® MotionStudio for programming, monitoring, troubleshooting.
Modes: Jog, reference homing, positioning, synchronous operation.
8. Safety Instructions
Install/wire/commission only by qualified personnel.
High voltage remains after power‑off; wait ≥5 minutes for capacitor discharge.
Use shielded cables and a qualified external EMC filter.
9. Maintenance & Troubleshooting
Routine: Check connections and ventilation; clean dust with dry compressed air.
Common Faults: Overcurrent (OC), Overvoltage (OV), Overtemperature (OT), Encoder Error. View via keypad or software.
10. Typical Applications
Conveyors, cranes, hoists
Packaging, textile, woodworking machinery
Large fans, pumps, process equipment
Standard industrial environments without harsh conditions
Get a Quote