MDX61B0450-503-4-0T MOVIDRIVE® B Series AC Drive | SEW-EURODRIVE
Description
1. General Description
2. Model Code Explanation
MDX61B: MOVIDRIVE B series, dual expansion slots for encoder and fieldbus modules
0450: Rated power 45 kW (Constant Torque)
503: 3-phase 380–500 V AC, no integrated EMC filter
4: Integrated brake chopper, supports four-quadrant regenerative operation
0T: Conformal coated PCB for harsh working conditions
3. Technical Specifications
3.1 Electrical Parameters
Input Voltage: 3×380–500 V AC (-15% ~ +10%), 50/60 Hz
Rated Input Current: 89 A (at 400 V)
Rated Output Power: 45 kW (CT)
Rated Output Current: 89 A
Apparent Power: 62.5 kVA
Output Frequency Range: 0–599 Hz
Control Modes: V/f control, VFC vector control, CFC closed-loop vector control, servo control
Overload Capability: 150% rated current for 60 s; 175% rated current for 2 s
Switching Frequency: 4 kHz, 8 kHz, 12 kHz, 16 kHz (adjustable)
Safety Function: STO (Safe Torque Off), compliant with PL d / SIL 2
3.2 Mechanical & Environmental Parameters
Protection Class: IP20 (cabinet installation only)
Dimensions (W × H × D): 280 × 522 × 307 mm
Weight: Approximately 27 kg
Operating Temperature: 0 °C to +40 °C. Power derating is required if ambient temperature exceeds 40 °C.
Storage Temperature: -25 °C to +70 °C
PCB Treatment: Conformal coating for protection against moisture, dust and mild corrosion
Altitude: No power derating below 1000 m; derate 1% per additional 100 m above 1000 m
Certifications: CE, UL, RoHS, EAC
4. Version Comparison
00: Standard non-coated PCB, for clean and dry industrial environments
0T: Conformal coated PCB, for humid, dusty or mildly corrosive environments
50: Special factory customized version with dedicated firmware and settings
5. Main Features
Four-quadrant operation with built-in brake chopper enables regenerative braking and energy recovery.
External EMC filter is required to meet electromagnetic compatibility standards.
Conformal coated PCB improves durability and reliability under harsh operating conditions.
Modular design supports optional encoder and various fieldbus modules for function expansion.
Integrated IPOSplus® motion system provides positioning, electronic gearing and master-slave synchronization functions.
Standard STO safety function complies with international machine safety regulations.
6. Installation & Wiring
Mounting Method: Vertical installation inside control cabinet.
Ventilation Clearance: Keep a minimum gap of 100 mm at top and bottom, and 50 mm on both sides.
Main Terminals:
X1: Mains connection (L1, L2, L3, PE)
X2: Motor connection (U, V, W, PE)
X4: DC link terminals for external brake resistor
X11: Analog input (0–10 V / 4–20 mA)
X13: 24 V DC digital inputs and outputs
X15 / X16: Encoder interfaces
7. Operation & Commissioning
Local Operation: DBG60B handheld keypad for parameter setting, manual operation and fault inquiry.
PC Commissioning: MOVITOOLS® MotionStudio for program editing, real-time monitoring and fault diagnosis.
Operating Modes: Jog mode, reference homing, positioning mode, synchronous operation.
8. Safety Instructions
Installation, wiring and commissioning shall only be performed by qualified electrical personnel.
Dangerous high residual voltage remains inside the drive after power cut-off. Wait at least 5 minutes for full capacitor discharge before touching internal components and terminals.
Use shielded cables for motor and signal wiring, and match with a qualified external EMC filter.
9. Maintenance & Troubleshooting
Routine Maintenance: Regularly inspect cable connections and ventilation passages. Remove accumulated dust with dry compressed air.
Typical Faults: Overcurrent (OC), Overvoltage (OV), Overtemperature (OT), Encoder Error. Fault information can be read via keypad or supporting software.
10. Typical Applications
Conveyors, cranes and hoists
Packaging, textile and woodworking machinery
Large fans, pumps and process production equipment
Industrial sites with humid, dusty or mildly corrosive operating conditions