MDX61B0370-503-4-00 MOVIDRIVE® B Series AC Drive | SEW-EURODRIVE
Description
1. General Description
2. Model Code Explanation
MDX61B: MOVIDRIVE B series, dual expansion slots for encoder and fieldbus modules
0370: Rated power 37 kW (Constant Torque)
503: 3‑phase 380–500 V AC, no integrated EMC filter
4: Integrated brake chopper, supports four‑quadrant regenerative operation
00: Standard non‑coated PCB
3. Technical Specifications
3.1 Electrical Parameters
Input Voltage: 3×380–500 V AC (‑15% ~ +10%), 50/60 Hz
Rated Input Current: 65.7 A (at 400 V)
Rated Output Power: 37 kW (CT)
Rated Output Current: 73 A
Apparent Power: 51.1 kVA
Output Frequency Range: 0–599 Hz
Control Modes: V/f control, VFC vector control, CFC closed‑loop vector control, servo control
Overload Capability: 150% rated current for 60 s; 175% rated current for 2 s
Switching Frequency: 4 kHz / 8 kHz / 12 kHz / 16 kHz (adjustable)
Safety Function: STO (Safe Torque Off), compliant with PL d / SIL 2
3.2 Mechanical & Environmental Parameters
Protection Class: IP20 (cabinet installation only)
Dimensions (W × H × D): 280 × 520 × 307 mm
Weight: Approximately 27 kg
Operating Temperature: 0 °C to +40 °C (power derating above 40 °C)
Storage Temperature: ‑25 °C to +70 °C
Altitude: No derating below 1000 m; derate 1% per 100 m above 1000 m
Certifications: CE, UL, RoHS, EAC
4. Version Comparison
00: Standard non‑coated PCB, clean/dry environments
0T: Conformal coated PCB, humid/dusty/corrosive environments
50: Special factory custom version
5. Main Features
Four‑quadrant Operation: Built‑in brake chopper enables regenerative braking and energy recovery.
External EMC Design: Requires external EMC filter for compliance.
Modular Expansion: Optional encoder and fieldbus modules (PROFIBUS, EtherCAT, CANopen).
Integrated Motion Control: IPOSplus® for positioning, electronic gearing, master‑slave sync.
Standard PCB: Cost‑effective for standard industrial conditions.
STO Safety: Complies with PL d / SIL 2.
6. Installation & Wiring
Mounting: Vertical in control cabinet.
Ventilation Clearance: 100 mm top/bottom, 50 mm sides.
Main Terminals:
X1: Mains (L1, L2, L3, PE)
X2: Motor (U, V, W, PE)
X4: DC link for external brake resistor
X11: Analog input (0–10 V / 4–20 mA)
X13: 24 V DC digital I/O
X15/X16: Encoder interfaces
7. Operation & Commissioning
Local: DBG60B keypad for parameters, manual operation, fault diagnosis.
PC: MOVITOOLS® MotionStudio for programming, monitoring, troubleshooting.
Modes: Jog, reference homing, positioning, synchronous operation.
8. Safety Instructions
Install/wire/commission only by qualified personnel.
High voltage remains after power‑off; wait ≥5 minutes for capacitor discharge.
Use shielded cables and qualified external EMC filter.
9. Maintenance & Troubleshooting
Routine: Check connections and ventilation; clean dust with dry compressed air.
Common Faults: Overcurrent (OC), Overvoltage (OV), Overtemperature (OT), Encoder Error. View via keypad or software.
10. Typical Applications
Conveyors, cranes, hoists
Packaging, textile, woodworking machinery
Large fans, pumps, process equipment
Standard industrial environments without harsh conditions
Get a Quote