MDX61B0300-503-4-50 MOVIDRIVE® B Series AC Drive | SEW-EURODRIVE
Description
1. General Description
2. Model Code Explanation
MDX61B: MOVIDRIVE B series, equipped with dual expansion slots for encoder and fieldbus modules
0300: Rated power 30 kW (Constant Torque)
503: 3-phase 380–500 V AC, no integrated EMC filter
4: Integrated brake chopper, enables four-quadrant regenerative operation
50: Special factory customized version
3. Technical Specifications
3.1 Electrical Parameters
Input Voltage: 3×380–500 V AC (-15% ~ +10%), 50/60 Hz
Rated Input Current: 54 A (at 400 V)
Rated Output Power: 30 kW (CT)
Rated Output Current: 60 A
Apparent Power: 41.6 kVA
Output Frequency Range: 0–599 Hz
Control Modes: V/f control, VFC vector control, CFC closed-loop vector control, servo control
Overload Capacity: 150% rated current for 60 seconds; 200% rated current for 1 second
Switching Frequency: 4 kHz, 8 kHz, 12 kHz, 16 kHz (adjustable)
Safety Function: STO (Safe Torque Off), compliant with PL d / SIL 2
3.2 Mechanical & Environmental Parameters
Protection Class: IP20 (for cabinet installation only)
Dimensions (W × H × D): 200 × 465 × 308 mm
Weight: Approximately 15 kg
Operating Temperature: 0 °C to +40 °C. Power derating is necessary when the ambient temperature exceeds 40 °C.
Storage Temperature: -25 °C to +70 °C
Altitude: No power derating below 1000 m. Derate power by 1% per 100 m above 1000 m.
Certifications: CE, UL, RoHS, EAC
4. Version Comparison
00: Standard non-coated PCB, suitable for clean and dry industrial environments
0T: Conformal coated PCB, suitable for humid, dusty or mildly corrosive working conditions
50: Special customized version with exclusive factory firmware and settings
5. Main Features
Four-quadrant operation with built-in brake chopper realizes regenerative braking and energy recovery.
Designed for external EMC configuration; an external EMC filter must be installed on site.
Modular structure allows expansion with optional encoder and various fieldbus modules.
Integrated IPOSplus® motion system supports positioning, electronic gearing and master-slave synchronization.
Pre-configured special parameters and firmware to meet customized application requirements.
Standard STO safety function meets international machine safety regulations.
6. Installation & Wiring
Mounting: Install vertically inside a control cabinet.
Ventilation Clearance: Keep a minimum gap of 100 mm at the top and bottom, and 50 mm on both sides.
Main Terminals:
X1: Power supply terminals (L1, L2, L3, PE)
X2: Motor connection terminals (U, V, W, PE)
X4: DC link terminals for external brake resistor connection
X11: Analog input (0–10 V / 4–20 mA)
X13: 24 V DC digital inputs and outputs
X15 / X16: Encoder interfaces
7. Operation & Commissioning
Local Control: Use DBG60B handheld keypad for parameter setting, manual operation and fault inquiry.
PC Commissioning: Use MOVITOOLS® MotionStudio for programming, real-time monitoring and fault diagnosis.
Available Modes: Jog mode, reference homing, positioning mode and synchronous operation.
8. Safety Instructions
Only qualified electrical personnel are permitted to perform installation, wiring and commissioning work.
High residual voltage remains inside the drive after power is cut off. Wait at least 5 minutes for full capacitor discharge before touching internal terminals.
Apply shielded cables for motor and signal wiring, and use a qualified external EMC filter.
9. Maintenance & Troubleshooting
Routine Maintenance: Regularly check cable connections and ventilation paths. Clean dust with dry compressed air.
Common Faults: Overcurrent (OC), Overvoltage (OV), Overtemperature (OT) and Encoder Error. Fault codes can be checked via keypad or supporting software.
10. Typical Applications
Conveyors, cranes and hoists
Packaging, textile and woodworking machinery
Large fans, pumps and process equipment
Industrial facilities with customized drive demands and external EMC design
Get a Quote