MDX61B0220-503-4-00 MOVIDRIVE® B Series AC Drive | SEW-EURODRIVE
Description
1. General Description
2. Model Code Explanation
MDX61B: MOVIDRIVE B series, dual expansion slots (encoder + fieldbus)
0220: Rated power 22 kW (Constant Torque)
503: 3‑phase 380–500 V AC, no integrated EMC filter
4: Integrated brake chopper, four‑quadrant regenerative operation
00: Standard PCB (no conformal coating)
3. Technical Specifications
3.1 Electrical Parameters
Input Voltage: 3×380–500 V AC (‑15% / +10%), 50/60 Hz
Rated Input Current: 41.4 A (at 400 V)
Rated Output Power: 22 kW (CT)
Rated Output Current: 46 A
Apparent Power: 31.9 kVA
Output Frequency: 0–599 Hz
Control Modes: V/f, VFC vector, CFC closed‑loop vector, servo control
Overload: 150% / 60 s; 200% / 1 s
Switching Frequency: 4/8/12/16 kHz (adjustable)
Safety: STO (Safe Torque Off), PL d / SIL 2
3.2 Mechanical & Environmental
Protection Class: IP20 (cabinet mounting only)
Dimensions (W×H×D): 250 × 485 × 315 mm
Weight: ≈12.6 kg (27.8 lb)
Operating Temperature: 0 to +45 °C (derate above 40 °C)
Storage Temperature: ‑25 to +70 °C
PCB: Standard (non‑coated)
Altitude: ≤1000 m (no derating); >1000 m: 1% / 100 m
Certifications: CE, UL, RoHS, EAC
4. Main Features
22 kW High Power: Suitable for medium‑to‑heavy industrial loads.
Four‑Quadrant Operation: Integrated brake chopper enables regenerative braking and energy recovery.
External EMC Design: No internal filter; ideal for systems with dedicated external EMC solutions.
Standard PCB (00): For clean, dry environments (use 0T for conformal coating).
Modular Expandability: Supports plug‑in encoder and fieldbus modules (PROFIBUS, EtherNet/IP, CANopen).
Integrated Motion Control: IPOSplus® for positioning, electronic gearing, and master‑slave sync.
5. Typical Applications
Conveyors, cranes, and hoists
Packaging, textile, and woodworking machinery
Fans, pumps, and process equipment
General automation with asynchronous/synchronous motors in clean, dry conditions
6. Version Comparison
00: Standard PCB, no EMC filter → Clean/dry environments
0T: Conformal coated PCB, no EMC filter → Harsh (humid/dusty) environments
5A3: Standard PCB, integrated C2 EMC filter → General industrial use
Get a Quote