MDX61B0150-503-4-0T MOVIDRIVE® B Series AC Drive | SEW-EURODRIVE
Description
1. General Description
2. Model Code Explanation
MDX61B: MOVIDRIVE B series, equipped with dual expansion slots for encoder and fieldbus modules
0150: Rated power 15 kW (Constant Torque)
503: 3-phase 380–500 V AC, without integrated EMC filter (external EMC filter required)
4: Integrated brake chopper, supports four-quadrant regenerative operation
0T: Application version with conformal coated PCB for harsh working conditions
3. Technical Specifications
3.1 Electrical Parameters
Input Voltage: 3×380–500 V AC (-15% ~ +10%), 50/60 Hz
Rated Input Current: 28.8 A
Rated Output Power: 15 kW (CT)
Rated Output Current: 32 A
Apparent Power: 22.2 kVA
Output Frequency Range: 0–599 Hz
Control Modes: VFC (V/f control), CFC (closed-loop vector control), Servo control
Overload Capability: 150% rated current for 60 s; 200% rated current for 1 s
Switching Frequency: 4 kHz / 8 kHz / 12 kHz / 16 kHz (adjustable)
Safety Function: STO (Safe Torque Off), compliant with PL d / SIL 2
3.2 Mechanical & Environmental Parameters
Protection Class: IP20 (for cabinet installation only)
Dimensions (W × H × D): 200 × 465 × 308 mm
Weight: Approximately 15 kg
Operating Temperature: 0 °C to +45 °C (power derating required above 40 °C)
Storage Temperature: -25 °C to +70 °C
PCB Treatment: Conformal coating (moisture, dust and mild corrosion resistance)
Altitude: No power derating below 1000 m; derate 1% per additional 100 m above 1000 m
Certifications: CE, UL, RoHS, EAC
4. Main Features
Conformal Coated PCB: Provides reliable protection against moisture, dust and mild corrosion for harsh industrial sites.
External EMC Design: No internal EMC filter, suitable for systems with independent external EMC configuration.
Four-quadrant Operation: Built-in brake chopper realizes regenerative braking and energy recovery.
Integrated IPOSplus® Motion Control: Supports positioning, electronic gearing and master-slave synchronous operation.
Modular Expansion: Compatible with optional encoder and various fieldbus modules for extended functions.
Industrial Safety: STO safety function meets international machine safety standards.
5. Installation & Wiring
Mounting Method: Vertical installation inside control cabinet.
Ventilation Clearance: Minimum 100 mm space at top and bottom, 50 mm on both sides.
Main Terminals:
X1: Mains connection (L1, L2, L3, PE)
X2: Motor connection (U, V, W, PE)
X4: DC link terminals for external brake resistor
X11: Analog input (0–10 V / 4–20 mA)
X13: 24 V DC digital inputs and outputs
X15 / X16: Encoder interfaces
6. Operation & Commissioning
Local Operation: DBG60B handheld keypad for parameter setting, manual operation and fault inquiry.
PC Commissioning: MOVITOOLS® MotionStudio for program editing, real-time monitoring and fault diagnosis.
Operating Modes: Jog mode, reference homing, positioning mode, synchronous operation.
7. Safety Instructions
Installation, wiring and commissioning shall only be performed by qualified electrical personnel.
Dangerous high voltage remains inside the unit after power-off. Wait at least 5 minutes for capacitor full discharge before touching internal terminals.
Use shielded cables for motor and signal wiring. Match with qualified external EMC filter to meet electromagnetic compatibility requirements.
8. Maintenance & Troubleshooting
Routine Maintenance: Regularly inspect cable connections and ventilation passages. Remove surface dust with dry compressed air.
Typical Fault Codes: OC (Overcurrent), OV (Overvoltage), OT (Overtemperature), Encoder Error. All faults can be checked via keypad or supporting software.
9. Typical Applications
Conveyors, cranes and hoists
Packaging, textile and woodworking machinery
Large fans, pumps and process production equipment
Industrial facilities with humid, dusty or mildly corrosive environment and external EMC design.
10. Version Comparison
00 version: Non-coated PCB, no internal EMC filter → For clean and dry environments
0T version: Conformal coated PCB, no internal EMC filter → For harsh environments with moisture and dust
5A3 version: Standard PCB with integrated C2 EMC filter → For general industrial use without extra EMC devices
Get a Quote