MDX61B0110-5A3-4-0T MOVIDRIVE® B Series AC Drive (SEW‑EURODRIVE)
Description
1. General Information
Model: MDX61B0110-5A3-4-0T
Manufacturer: SEW‑EURODRIVE
Series: MOVIDRIVE® MDX61B
Rated Power: 11 kW (Constant Torque)
Application: High‑performance speed, torque, and positioning control for three‑phase asynchronous/synchronous motors; conformal coated PCB for harsh industrial environments (humid, dusty, mildly corrosive).
2. Model Decoding
MDX61B: MOVIDRIVE B series, dual expansion slots (encoder + fieldbus)
0110: Rated power 11 kW
5A3: 3‑phase 380–500 V AC, integrated Class C2 EMC filter
4: Built‑in brake chopper, four‑quadrant regenerative operation
0T: Conformal coated PCB (technology/application version), enhanced protection for harsh conditions
3. Technical Specifications
3.1 Electrical Parameters
Input Voltage: 3×380–500 V AC (‑15% / +10%), 50/60 Hz
Rated Input Current: 21.6 A
Rated Output Power: 11 kW (CT)
Rated Output Current: 24 A
Apparent Power: 16.8 kVA
Output Frequency: 0–599 Hz
Control Modes: VFC (V/f), CFC (closed‑loop vector), Servo control
Overload: 150% / 60 s; 200% / 1 s
Switching Frequency: 4/8/12/16 kHz (adjustable)
Safety: STO (Safe Torque Off), PL d / SIL 2
3.2 Mechanical & Environmental
Protection Class: IP20 (cabinet mount only)
Dimensions (W×H×D): 135 × 315 × 285 mm
Weight: ~6.6 kg
Operating Temp: 0 °C to +50 °C
Storage Temp: ‑25 °C to +70 °C
PCB Protection: Conformal coated (0T version)
Altitude: No derating ≤1000 m; 1% / 100 m above 1000 m
Certifications: CE, UL, RoHS, EAC
4. Core Features
Conformal Coated PCB: 0T version provides protection against moisture, dust, and mild corrosion (vs. 00 standard non‑coated).
Integrated C2 EMC Filter: Simplifies wiring, meets industrial EMC standards.
Four‑Quadrant Operation: Internal brake chopper enables regenerative braking/energy recovery.
IPOSplus® Motion Control: Positioning, electronic gearing, master‑slave sync; application modules for winding, flying saw, etc..
Modular Expansion: Encoder (e.g., DEU21B) and fieldbus modules (PROFINET, EtherCAT, etc.).
Harsh Environment Ready: Coated PCB ensures reliability in humid/dusty industrial sites.
5. Installation & Wiring
Mounting: Vertical in control cabinet.
Clearance: ≥100 mm top/bottom, ≥50 mm sides.
Main Terminals:
X1 (Mains): L1, L2, L3, PE
X2 (Motor): U, V, W, PE
X4 (DC Bus): +UZ, –UZ, PE (external brake resistor)
X11: Analog input (0–10 V / 4–20 mA)
X13: 24 V DC digital I/O
X15/X16: Encoder interfaces
6. Operation & Commissioning
Local: DBG60B keypad (parameters, operation, faults).
PC: MOVITOOLS® MotionStudio (programming, monitoring, diagnostics).
Modes: Jog, reference homing, positioning, synchronous operation.
7. Safety Instructions
Qualified electricians only for installation/wiring.
High voltage remains after power‑off; wait ≥5 minutes for capacitor discharge.
Use shielded cables for motor/signal wiring to maintain EMC performance.
8. Maintenance & Troubleshooting
Routine: Check connections/ventilation; clean dust with dry compressed air.
Common Faults: OC (overcurrent), OV (overvoltage), OT (overtemp), encoder error.
9. Applications
Conveyors, cranes, hoists
Packaging, textile, woodworking machinery
Fans, pumps, process equipment
Harsh environments: Humid, dusty, mildly corrosive industrial sites
10. Version Differences
00: Non‑coated PCB, C2 filter → clean/dry environments
0T: Conformal coated PCB, C2 filter → harsh environments (humid/dusty)
50: No internal filter, OEM version → external EMC design systems