MDX61B0110-5A3-4-00 MOVIDRIVE® B Series AC Drive (SEW‑EURODRIVE)
Description
1. General Description
2. Model Code Explanation
MDX61B: MOVIDRIVE B series, dual expansion slots for encoder and fieldbus modules
0110: Rated power 11 kW (constant torque)
5A3: 3-phase 380–500 V AC power supply, integrated Class C2 EMC filter
4: Integrated brake chopper, supports four-quadrant regenerative operation
00: Standard version with non-conformal coated PCB, for clean indoor conditions
3. Technical Specifications
3.1 Electrical Ratings
Input voltage: 3×380–500 V AC (-15% ~ +10%), 50/60 Hz
Rated input current: 21.6 A
Rated output power: 11 kW (CT)
Rated output current: 24 A
Apparent power: 16.8 kVA
Output frequency range: 0–599 Hz
Control modes: VFC (V/f), CFC (closed-loop vector), Servo control
Overload capability: 150% rated current for 60 s; 200% rated current for 1 s
Switching frequency: 4 / 8 / 12 / 16 kHz (adjustable)
Safety function: STO (Safe Torque Off), certified to PL d / SIL 2
3.2 Mechanical & Environmental
Protection class: IP20 (cabinet mounting only)
Dimensions (W × H × D): 135 × 315 × 285 mm
Weight: Approx. 6.6 kg
Operating temperature: 0 °C to +45 °C
Storage temperature: -25 °C to +70 °C
Altitude: No derating below 1000 m; derate 1% per additional 100 m above 1000 m
PCB treatment: Standard non-coated
Certifications: CE, UL, RoHS, EAC
4. Main Features
Built-in Class C2 EMC filter, fully compliant with industrial EMC requirements.
Internal brake chopper enables four-quadrant operation and regenerative braking.
Integrated IPOSplus® motion system for positioning, electronic gearing and master-slave synchronization.
Modular design, expandable with optional encoder and fieldbus modules.
Reliable STO safety function for machine safety protection.
Cost-effective standard model for common industrial applications.
5. Installation & Wiring
Mounting: Vertical installation inside control cabinet.
Ventilation clearance: Minimum 100 mm at top and bottom, 50 mm on both sides.
Main terminals:
X1: Mains connection (L1, L2, L3, PE)
X2: Motor connection (U, V, W, PE)
X4: DC link terminals for external brake resistor
X11: Analog input (0–10 V / 4–20 mA)
X13: 24 V DC digital inputs and outputs
X15 / X16: Encoder interfaces
6. Operation & Commissioning
Local control: DBG60B handheld keypad for parameter setting, operation and fault checking.
PC commissioning: MOVITOOLS® MotionStudio for programming, monitoring and diagnostics.
Operating modes: Jog mode, reference homing, positioning mode, synchronous operation.
7. Safety Notes
Installation and commissioning must be performed by qualified electrical personnel.
High voltage remains in DC bus after power cut-off. Wait at least 5 minutes for full discharge before touching internal terminals.
Use shielded cables for motor and signal wiring to maintain EMC performance.
8. Maintenance & Troubleshooting
Routine maintenance: Regularly check wiring and ventilation; remove dust with dry compressed air.
Typical faults: Overcurrent (OC), overvoltage (OV), overtemperature (OT), encoder error. Fault codes can be displayed on keypad or software.
9. Application Scope
Conveyors, cranes and hoists
Packaging, textile and woodworking machinery
Fans, pumps and process equipment
General automation systems requiring precise speed and position control
10. Version Comparison
00: Non-coated PCB, with integrated C2 EMC filter → Clean & dry environments
0T: Conformal coated PCB, with integrated C2 EMC filter → Humid, dusty or mildly corrosive environments
50: No built-in EMC filter, special OEM version → Systems with external EMC configuration
Get a Quote