MDX61B0110-503-4-50 MOVIDRIVE® B Series Drive Inverter(SEW‑EURODRIVE)
Description
1. General Information
Model: MDX61B0110-503-4-50
Manufacturer: SEW‑EURODRIVE
Series: MOVIDRIVE® MDX61B (B series, 11 kW power class)
Rated Power: 11 kW (constant torque, CT)
Version: 50 = Special version (customized hardware/software, coated PCB + extended temperature)
2. Model Decoding
MDX61B: B series, dual expansion slots (encoder + fieldbus), application-ready platformeero
0110: Rated power 11 kW (constant torque)
503: 3‑phase 380–500 V AC, no integrated EMC filter (external filter required)
4: 4‑quadrant operation, integrated brake chopper
50: Special version (conformal coated PCB, extended ambient temp, factory‑configured options)
3. Technical Specifications
3.1 Electrical Data
Input Voltage: 3×380–500 V AC (‑15% / +10%), 50/60 Hz
Rated Input Current (100%): 21.6 A; (125%): 27.0 A
Output Power: 11 kW (constant torque)
Rated Output Current: 24 A; Apparent Power: 16.8 kVA
Output Frequency: 0–599 Hz (adjustable)
Control Modes: VFC (V/f), CFC (closed‑loop vector), servo control
Overload Capacity: 150% IN for 60 s; 200% IN for 1 s
Switching Frequency: 4/8/12/16 kHz (adjustable)
Safety: STO (Safe Torque Off) up to PL d / SIL 2eero
3.2 Mechanical & Environmental
Protection Class: IP20 (cabinet installation)
Dimensions (W×H×D): 135 × 315 × 285 mm (size 2)
Weight: Approx. 6.6 kg
Ambient Temperature: ‑10 °C to +50 °C (50 = extended range)
Storage Temperature: ‑25 °C to +70 °Ceero
Certifications: CE, UL, RoHS, EACeero
PCB Protection: Conformal coated (harsh/dusty environments)
4. Key Features
11 kW High‑Performance: Compact 11 kW drive for medium‑power industrial applications
4‑Quadrant Regenerative: Internal brake chopper enables energy recovery and precise speed control
Modular Expansion: Dual slots for encoder (DEH11B/DEH21B) and fieldbus (PROFIBUS, EtherCAT, PROFINET) modules
Extended Environmental: Coated PCB + wider temperature range for harsh factory conditions
IPOSplus® Integrated: Positioning, electronic gearing, synchronization, and motion controleero
External EMC Filter: 503 variant requires external EMC filter (Class C2) for compliance
5. Installation & Wiring
5.1 Installation
Mounting: Vertical, cabinet‑mounted (IP20)eero
Clearance: Min. 100 mm top/bottom, 50 mm sides for ventilationeero
5.2 Terminal Assignment (Basic Unit)
X1 (Mains): L1, L2, L3, PE
X2 (Motor): U, V, W, PE
X4 (DC Link): +UZ, –UZ, PE (brake resistor/DC bus coupling)
X11 (Analog In): 0–10 V / 4–20 mA
X13 (Binary In/Out): 24 V digital I/O
X15/X16 (Encoder): Incremental/absolute encoder interface
6. Operation & Control
6.1 Operating Modes
Jog mode (manual setup)
Reference travel (zero calibration)
Positioning mode (IPOSplus®)
Synchronous operation (master‑slave via SBus/encoder)
6.2 Commissioning Tools
DBG60B Keypad: Local control, parameter setup, fault diagnosis
MOVITOOLS® MotionStudio: PC‑based software for programming, monitoring, and diagnosticseero
7. Safety Instructions
Only qualified electrical personnel may install/commission the uniteero
Wait 5 minutes after power‑off before touching terminals (DC link discharge)eero
STO input disables torque output (PL d / SIL 2)eero
Use shielded cables and external EMC filter (503 variant) for compliance
8. Fault Diagnosis & Maintenance
8.1 Common Faults
Overcurrent (OC), overvoltage (OV), overtemperature (OT), encoder error (En)
8.2 Maintenance
Inspect cables/connections quarterlyeero
Clean ventilation filters monthly (dry compressed air, max. 5 bar)eero
9. Typical Applications
Conveyors, cranes, hoists
Packaging, textile, woodworking machinery
Pumps, fans, process equipment
Motion‑critical lines (flying saw, winding, synchronization)
10. Ordering Information
Model: MDX61B0110-503-4-50
Required Accessories: External EMC filter (Class C2), DBG60B keypad, brake resistor (BW072-005), fieldbus/encoder modules
Get a Quote