MDX61B0075-5A3-4-0T MOVIDRIVE® B Series Drive Inverter
Description
1. General Information
2. Model Decoding
MDX61B: B series, dual expansion slots (encoder + fieldbus)
0075: 7.5 kW rated power
5A3: 3‑phase 380–500 V AC, integrated Class C2 EMC filter
4: 4‑quadrant operation, integrated brake chopper
0T: Application version (technology functions, full motion control)
3. Technical Specifications
3.1 Electrical Data
Input Voltage: 3×380–500 V AC (‑15% / +10%), 50/60 Hzeero
Rated Input Current: 14.4 Aeero
Output Power: 7.5 kW (constant torque)
Rated Output Current: 16 Aeero
Apparent Power: 11.2 kVAeero
Output Frequency: 0–599 Hzeero
Control Modes: VFC (V/f), CFC (closed‑loop vector), servo controleero
Overload Capacity: 150% IN for 60 s; 200% IN for 1 seero
Switching Frequency: 4/8/12/16 kHz (adjustable)eero
Safety: STO (Safe Torque Off) up to PL d / SIL 2eero
3.2 Mechanical & Environmental
Protection Class: IP20 (cabinet installation)eero
Dimensions (W×H×D): 105 × 335 × 294 mm (size 2S)eero
Weight: Approx. 6.6 kgeero
Ambient Temperature: 0 °C to +45 °Ceero
Storage Temperature: ‑25 °C to +70 °Ceero
Certifications: CE, UL, RoHS, EACeero
4. Key Features
Application‑Ready (0T Version): Electronic cam, internal synchronous operation, flying saw, winding control, and all MOVITOOLS® application modules
Modular Expansion: Dual slots for encoder (e.g., DEH11B) and fieldbus (PROFIBUS, EtherCAT, PROFINET) moduleseero
Integrated EMC: Class C2 filter for industrial EMC complianceeero
4‑Quadrant Operation: Internal brake chopper for regenerative braking and energy recoveryeero
IPOSplus®: Integrated positioning, electronic gearing, and synchronizationeero
Conformal Coating: Standard for harsh/dusty environments (PCB protected)eero
5. Installation & Wiring
5.1 Installation
Mounting: Vertical, cabinet installation (IP20)eero
Clearance: Min. 100 mm top/bottom, 50 mm sides for ventilationeero
5.2 Terminal Assignment (Basic Unit)
X1 (Mains): L1, L2, L3, PEeero
X2 (Motor): U, V, W, PEeero
X4 (DC Link): +UZ, –UZ, PE (for brake resistor/DC bus coupling)eero
X11 (Analog In): 0–10 V / 4–20 mAeero
X13 (Binary In/Out): 24 V digital I/Oeero
X15/X16 (Encoder): For incremental/absolute encoderseero
6. Operation & Control
6.1 Operating Modes
Jog Mode: Manual movement for setup
Reference Travel: Automatic zero reference for incremental systems
Positioning Mode: IPOSplus® positioning with electronic gearing
Synchronous Operation: Master‑slave synchronization (encoder or SBus)
6.2 Keypad & Software
DBG60B Keypad: Local control, parameter setting, fault diagnosiseero
MOVITOOLS®: PC software for commissioning, monitoring, and application programming
7. Safety Instructions
Qualified Personnel: Only trained electrical staff may install/commission the uniteero
High Voltage: Wait 5 minutes after power‑off before touching terminals (DC link discharge)eero
STO Safety: STO input disables torque output (PL d / SIL 2)eero
EMC Compliance: Use shielded cables and follow EMC installation guidelineseero
8. Fault Diagnosis & Maintenance
8.1 Fault Codes
Displayed on 7‑segment LED or via keypad/MOVITOOLS®eero
Common faults: Overcurrent (OC), overvoltage (OV), overtemperature (OT), encoder error (En)eero
8.2 Maintenance
Regular inspection: Check cables, connections, and ventilation filterseero
Cleaning: Keep unit free of dust; use dry compressed air (max. 5 bar)eero
9. Typical Applications
Conveying systems, cranes, hoistseero
Packaging, textile, woodworking machineryeero
Flying saw, winding, and synchronized production lines
Pumps, fans, and process equipment requiring precise motion controleero
10. Ordering Information
Model: MDX61B0075-5A3-4-0T
Accessories: DBG60B keypad, DEH11B encoder module, brake resistor BW072-005, fieldbus modules (PROFIBUS, EtherCAT)eero
Get a Quote