MDX61B0055-5A3-4-00(SEW‑EURODRIVE)
Description
1. Model Decoding
MDX61B: MOVIDRIVE B series, dual expansion slots for encoder/fieldbus modules
0055: Rated power 5.5 kW (constant torque)
5A3: 3‑phase 380–500 V AC, built‑in Class C2 EMC filter
4: Integrated brake chopper, supports four‑quadrant regenerative operation
00: Standard PCB (non‑coated), basic IPOSplus® functions
2. Electrical Ratings
Input: 3×380–500 V AC (‑15%/+10%), 50/60 Hz, 11.3 A rated input current
Output: 5.5 kW (constant torque), 12.5 A rated output current, 8.7 kVA apparent power
Frequency range: 0–599 Hz
Control modes: VFC (V/f), CFC (closed‑loop vector), SERVO (field‑oriented control)
Overload: 150% for 60 s, 200% for 1 s
PWM frequency: 4 kHz (default), optional 8/12/16 kHz
Braking: Internal brake chopper; external resistor ≥47 Ω required
EMC: Complies with Class C2 (EN 61800‑3)
Efficiency: IE2 (IEC 61800‑9‑2), standby loss ≈18 W
3. Mechanical & Environmental
Dimensions (W×H×D): 105 × 335 × 294 mm
Weight: ≈6.6 kg
Protection class: IP20 (cabinet‑mount only)
Ambient temp: ‑10 °C to +50 °C; derate above 40 °C
PCB coating: Standard (non‑coated) – clean/dry environments
Altitude: 1000 m max without derating; 1% per 100 m above 1000 m
Certifications: CE, UL, cUL, RoHS, STO (PL d, SIL 2)
4. I/O, Communication & Motion
Motion: IPOSplus® Basic (positioning, electronic cam, master‑slave sync)
Safety: STO (Safe Torque Off) (PL d, EN ISO 13849‑1)
Terminals:
Analog: ±10 V / 4–20 mA input
Digital: 6×24 V DC isolated inputs; 2×transistor outputs + 1×relay output
PTC: Motor thermistor input
Communication: Standard SBus & RS485 (Modbus RTU); expandable to PROFINET, CANopen, EtherCAT via option cards
5. Key Features
5.5 kW high power density in compact size
Built‑in Class C2 EMC filter reduces installation complexity
Four‑quadrant operation with integrated brake chopper
Standard non‑coated PCB for clean, dry industrial locations
Modular expansion for encoders and fieldbus communication
Integrated IPOSplus® motion control for positioning tasks
6. Version Differences (00 vs 0T vs 50)
00: Standard PCB + built‑in C2 filter – general industrial use
0T: Tropicalized (coated PCB) + C2 filter – humid/dusty environments
50: Standard PCB + no internal filter – OEM custom EMC designs
7. Typical Applications
Conveyors, packaging, material handling
Fans, pumps, compressors (energy‑saving speed control)
General automation machinery in clean/dry environments
Asynchronous/synchronous motor drive systems
Get a Quote