MDX61B0014-5A3-4-0
May 28, 2026

MDX61B0014-5A3-4-0

MDX61B0014-5A3-4-0 is a high‑performance 1.5 kW MOVIDRIVE MDX61B series AC drive by SEW‑EURODRIVE. It supports open‑loop V/f (VFC), closed‑loop vector (CFC), and servo control for three‑phase asynchronous/synchronous motors. The unit integrates a Class C2 EMC filter and a 4‑quadrant brake chopper for regenerative operation. The ‑0 suffix denotes the standard non‑coated PCB version, suitable for clean, dry industrial environments.

Description

1.1 Product Overview

MDX61B0014-5A3-4-0 is a high‑performance 1.5 kW MOVIDRIVE MDX61B series AC drive by SEW‑EURODRIVE. It supports open‑loop V/f (VFC), closed‑loop vector (CFC), and servo control for three‑phase asynchronous/synchronous motors. The unit integrates a Class C2 EMC filter and a 4‑quadrant brake chopper for regenerative operation. The ‑0 suffix denotes the standard non‑coated PCB version, suitable for clean, dry industrial environments.

1.2 Model Decoding

  • MDX61B: High‑performance drive with two option slots (encoder + fieldbus).

  • 0014: Rated motor power = 1.5 kW.

  • 5A3: 5 = 380–500 V AC; A = Class C2 EMC filter; 3 = three‑phase input.

  • 4: Integrated brake chopper (4‑quadrant operation).

  • 0: Standard version (non‑coated PCB, basic motion functions).

1.3 Safety Symbols

  • DANGER: High voltage inside—risk of electric shock.

  • WARNING: Potential personal injury or equipment damage.

  • CAUTION: Minor injury or component fault risk.

  • NOTE: Important operation/maintenance tips.

1.4 Intended Use

Speed, torque, and basic position control for 1.5 kW three‑phase motors. Ideal for conveyors, packaging machines, pumps, fans, and general automation in clean environments. Supports IPOSplus® motion functions: electronic cam, master‑slave synchronization, flying restart, and DC braking.

1.5 Warranty

Valid only if installation, commissioning, and operation follow this manual and SEW‑EURODRIVE guidelines. Damage from misuse, overload, unauthorized modification, or operation outside environmental specifications voids warranty.

2. Technical Specifications

2.1 Electrical Data (3 × 380–500 V AC, 50/60 Hz)

  • Rated input current: 3.6 A

  • Rated output power: 1.5 kW (constant torque) / 2.2 kW (variable torque)

  • Rated output current: 4.0 A

  • Apparent power: 2.8 kVA

  • Output frequency: 0–599 Hz

  • Overload capacity: 200% / 60 s; 175% / 2 seero

  • PWM carrier frequency: 4 kHz (default); 8/16 kHz selectableeero

  • Brake chopper: Integrated (external resistor ≥ 68 Ω required)eero

  • EMC filter: Class C2 (EN 61800‑3)

  • Protection class: IP20 (install in control cabinet)eero

2.2 Mechanical & Environmental

  • Dimensions (W×H×D): 105 × 260 × 95 mm

  • Weight: ~2.8 kg

  • Cooling: Temperature‑controlled forced aireero

  • Operating temperature: 0 °C to +50 °C (derate > 40 °C)eero

  • Storage temperature: −25 °C to +70 °C

  • Altitude: ≤ 1000 m (no derating); > 1000 m: −1% per 100 m

  • PCB: Standard (non‑coated)

2.3 Control Modes & Interfaces

Control Modes:
  • VFC (V/f): Open‑loop, general speed control.

  • CFC: Closed‑loop vector, high torque/accuracy.

  • Servo: With encoder, for permanent magnet motors.

Motion Functions:
  • IPOSplus®: Basic positioning, electronic cam, master‑slave sync, flying restart, DC braking.

  • PID controller: For flow/pressure closed‑loop controleero.

I/O Interfaces:
  • Analog inputs: ±10 V, 4–20 mAeero.

  • Digital inputs: 6 × 24 V DC isolatedeero.

  • Digital outputs: 2 × transistor, 1 × relayeero.

  • Motor thermistor input (PTC)eero.

  • Communication: SBus, RS485 (Modbus RTU).

  • Option slots: Encoder (e.g., DEH11B) + fieldbus (e.g., PROFINET, CANopen).

2.4 Safety & Protection

  • STO (Safe Torque Off): PL d complianteero.

  • Protection: Overcurrent, overvoltage, undervoltage, overtemperature, ground fault, short circuit, motor overtemperature (PTC)eero.

  • Fault response: Alarm + safe stop; fault code displayed on 7‑segment LEDeero.


3. Installation

3.1 Unpacking & Inspection

  • Check for physical damage (dents, scratches).

  • Verify model: MDX61B0014-5A3-4-0.

  • Confirm accessories: Mounting screws, terminal covers, manual.

3.2 Mounting

  • Install vertically in clean, dry, ventilated cabineteero.

  • Clearance: 100 mm top/bottom for airfloweero.

  • Avoid direct sunlight, heat sources, corrosive gases.

  • Fix with M4 screws; torque 1.2–1.5 Nmeero.

3.3 Wiring

Power Terminals:
  • L1/L2/L3: 3 × 380–500 V AC inputeero.

  • PE: Protective eartheero.

  • U/V/W: Motor outputeero.

  • +R/−R: External brake resistoreero.

Control Terminals:
  • X10: Digital inputs (24 V DC).

  • X11: Digital outputs.

  • X12: Analog inputs.

  • X13: PTC thermistor.

  • X14: Encoder (option).

  • X15: SBus/RS485.

  • X17: STO safety inputeero.

Wiring Guidelines:
  • Separate power and signal cables (≥ 20 cm)eero.

  • Use shielded cables for signals; ground shields at both endseero.

  • Torque terminals to 0.8–1.0 Nmeero.

  • Recheck all connections before power‑oneero.


4. Commissioning

4.1 Pre‑Start Check

  • All wiring correct and tighteero.

  • Terminal covers installedeero.

  • No foreign objects in cabineteero.

  • Ambient conditions within limitseero.

4.2 Basic Parameter Setup (via DBG60B keypad or MOVITOOLS®)

  1. Set motor data (nameplate):

    • Rated power: 1.5 kW.

    • Rated voltage: 400 V.

    • Rated current: ~4.0 A.

    • Rated frequency: 50 Hz.

    • Rated speed: 1450 rpm.

  2. Select control mode (VFC/CFC/Servo).

  3. Set frequency limits: Min 0 Hz, Max 50 Hz (default)eero.

  4. Accel/decel time: 5 s (default)eero.

  5. Configure I/O functions (e.g., start/stop, speed reference)eero.

  6. Run auto‑tuning (CFC/Servo mode)eero.

4.3 Operation

  • Jog mode: Test motor rotation and speed.

  • No‑load run: Check for noise, vibration, overheatingeero.

  • Loaded run: Gradually apply load; monitor current/tempeero.

  • Long‑term: Check parameters periodically; clean fan/filterseero.


5. Maintenance & Troubleshooting

5.1 Maintenance

  • Power off and wait 10 min before maintenance (capacitor discharge)eero.

  • Clean dust from heat sink/fan every 3–6 monthseero.

  • Check terminal tightness and cable insulationeero.

  • Replace damaged cables immediatelyeero.

5.2 Common Faults

  • Overvoltage (F01): High supply voltage; regenerative loadeero.

  • Undervoltage (F02): Low supply; loose wiringeero.

  • Overcurrent (F03): Short circuit; motor overloadeero.

  • Overtemp (F04): Dirty fan; high ambient tempeero.

  • Motor overtemp (F05): PTC trip; motor overloadeero.

  • Ground fault (F06): Cable/motor insulation failureeero.

Reset: Clear fault, reset drive, restart. If fault persists, contact SEW serviceeero.

6. Compliance & Certifications

  • CE (EN 61800‑3, EN 60204‑1)eero.

  • UL 508C, CSAeero.

  • RoHS complianteero.


7. Version Notes

  • ‑0: Standard non‑coated PCB, basic motion functions, for clean/dry environments.

  • ‑0T: Conformal coated PCB, advanced motion, for harsh environments (dust/moisture).


Get a Quote